City of Tallahassee

Awarded
State & Local
Solicitation #
H1204

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Under solicitation number H1204, the City of Tallahassee is awarded $81,049.19 through the Hazard Mitigation Grant Program to install backup power at Pump Station 106 in Tallahassee, Florida. The project involves the purchase and installation of a permanent generator, with a projected capacity of 80 kW or as determined by professional engineering standards, to prevent service interruptions for 550 customers and reduce the risk of sewer overflows during power outages. The scope of work includes the construction of a concrete pad, the installation of an automatic transfer switch, and all necessary electrical connections. To ensure resilience, the generator must be protected against wind according to ASCE 7 standards and secured against a 500-year flood event by being located outside the Special Flood Hazard Area or through specific mitigation activities complying with National Flood Insurance Program requirements. The installation must adhere to National Electrical Code working clearance requirements and all applicable federal, state, and local regulations. The performance period for this project is scheduled from May 07, 2025, to February 29, 2028.

General Info

City of Tallahassee awarded $81,049.19 for backup power installation at Pump Station 106.

Contract Value

$81,049.19

NAICS

N/A

Place of Performance

FL, USA

Set-Aside

NONE

Award Issued Date

Contract End Date

February 29, 2028

Documents

1
PDF, Low priorityaward
Low

Read the document

Every page of every file, in your free workspace.

Read the document

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseAwarded
Posted

Award Notice

Awarded

Contract was awarded

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyFlorida → Executive Office Of The Governor
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
As a Hazard Mitigation Grant Program (HMGP) project, the Sub-Recipient shall provide backup power to Pump Station 106, located in Tallahassee, Florida 32317. The HMGP project shall provide protection by purchasing and installing one (1) permanent generator with a capacity of 80 kW or the adequate size determined by the vendor and/or an electrical engineer during the bid process to appropriately support the critical infrastructure. The project includes construction of a concrete pad, installing an automatic transfer switch (ATS), and electrical connections. Currently, this infrastructure is unprotected without any source of backup power during power outages. An interruption in the electric power supply would result in a loss of service to 550 customers as well as increase the risk of sewer overflow events. This project shall allow the pump station to maintain operation during emergency events that could cause power outages. The generator(s) shall be protected against a 500-year flood event by implementing specific activities or by locating the generator(s) outside the Special Flood Hazard Area (SFHA), comply with applicable National Flood Insurance Program (NFIP) requirements and shall be protected against wind with a rated enclosure and appropriate anchoring based on its location requirements per ASCE 7 standards. The selected site shall provide sufficient space to maintain and fuel the generator(s) and shall comply with the National Electrical Code working clearance requirements. Activities shall be completed in strict compliance with Federal, State and Local applicable Rules and Regulations.