Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on December 6, 2018. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Composite Emergency Response Cargo Trailer

Closed
FA3016-19-U-0024Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

336214 - Travel Trailer and Camper Manufacturing

Place of Performance

TX

Set-Aside

NONE

Documents

2

approximate_trailer_design.xls

XLS

SOURCES_SOUGHT_.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA3016 502 Cons Cl
Contacts1 person available
OfficeJBSA LACKLAND, TX, 78236-5286, USA
Office AddressJBSA LACKLAND, TX, 78236-5286, USA
Contacts
Sharla J. MinerContract Specialist

Full Description

Show more
SOURCES SOUGHT SYNOPSIS The 502 Contracting Squadron, JBSA Randolph Air Force Base, is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support this requirement for an Emergency Response Cargo Trailer. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 336214. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. The government will evaluate market information to ascertain potential market capacity to provide the commodity consistent in scope and scale with those described in this notice and otherwise anticipated. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION, and a single award MAY be made. No feedback or evaluations will be provided to companies regarding their submissions. Submission Instructions: Interested parties who consider themselves qualified to perform the below-listed product are invited to submit a response to this Sources Sought Notice by 12:00pm CST Friday, 14 December 2018 or sooner. All responses under this Sources Sought Notice must be emailed to Sharla Miner, Contract Specialist at sharla.miner@us.af.mil. ALL RESPONSES MUST INCLUDE SPECIFICATION SHEET. Company Name: _______________________ GSA Vendor: Yes______ No______ Address _______________________ Phone No.: _______________________ E-mail Address _______________________ CAGE Code: _______________________ DUNS Number: _______________________ Name of POC: _______________________ Registered in System for Award Management (SAM): Yes______ No______ Refer to SAM at https://www.sam.gov/portal/public/SAM/. CLIN Description Qty U/I 0001 Emergency Response Cargo Trailer 1 EA The emergency response trailer will at a minimum meet the following salient features: a) Rear receiver pull (ball) hitch b) 24 foot maximum length (hitch to trailer bumper) c) Dual air conditioning (15,000BTU cooling, 14,000BTU heating) d) One heat pump (can be combined with air conditioning) e) Contain attached gas powered generator (7,000Watts) f) Converter (110V to 12V, 50amp) g) 70 amp breaker box with shore plug (plug needed to maintain environmental control when parked at storage location) h) Rear ramp door with spray on non-slip surface i) Interior height minimum 7.5foot j) LED interior lights k) LED exterior lighting on each side l) Electric Exterior Awning m) Interior Cabinets, wall mounted (12in deep) n) Interior Cabinets, floor mounted (24in deep) o) Locking Cabinet doors p) 6 GFI outlets q) Easy clean countertops/workstation r) Refrigerator (36x24in) s) Spray on Non slip flooring (easy decontamination) t) Weigh no more than 10,000lbs upon delivery u) SCBA Tank holder (6 wells) v) 4 tie down/D Rings w) Exterior light weight composite materials walls and Interior FRP Smooth Dry Erase Walls with Foil Insulation x) No exterior seems/rivets y) Minimal wood use (due to climate extremes in San Antonio) z) Fold down seating *see drawing attachment for example. Operating conditions: Flight members will utilize the response trailer during exercise/real world scenarios. The trailer will be used to store/transport equipment, and provide an area for responders to cool down before/after completing response operations as well as provide a quiet area for team briefings, equipment calibration etc. during said response events.

More opportunities from Department Of Defense → FA3016 502 Cons Cl

Same awarding agency

NAICS: 811310
New
Federal
Aviation Support Equipment Load Testing
Solicitation # F2MT2M6146AQ01
This Sources Sought Notice, solicitation number F2MT2M6146AQ01, is a market research effort to identify qualified sources capable of providing aviation support equipment load testing and maintenance for the 433rd MXS/AMXS at Joint Base San Antonio-Lackland, Texas. The scope of work involves non-personal services including annual preventive maintenance inspections, load tests, certification, and both scheduled and unscheduled repairs to ensure the safe operation of aircraft support equipment. All services must adhere to OSHA Standards 1910 and 1926, ANSI Standards B30.16 and B30-5, and applicable Air Force Instructions and Technical Orders. Key deliverables include an initial annual preventive maintenance schedule, certification reports due within two workdays of completion, and repair estimates provided within 48 hours of an initial survey. Performance requirements specify that standard preventive maintenance must be completed and equipment returned within 48 hours of pickup, while approved repairs must be returned within three business days. Interested vendors must submit their response, including company details, CAGE code, and a statement of capability with product literature, to Dalwyn Corporan-Polanco by 10:00 AM CDT on October 20, 2026. This notice is for research purposes only and does not constitute a solicitation or a promise to issue one.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

5 days ago

DEADLINE

in about 7 hours
View Details
NAICS: 238220
New
Federal
Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement
Solicitation # A070764SS
The 502d Contracting Squadron is conducting market research via a Sources Sought Synopsis to identify capable industry sources for the turnkey removal and replacement of 48 ceiling-suspended Dedicated Outside Air System Water-Source Heat Pumps at the JBSA Ft Sam Houston San Antonio Military Medical Center Dormitory Annex, specifically in buildings B3631 and B3635. The project is projected as a Firm-Fixed Priced Purchase Order under NAICS code 238220. The contractor must provide all personnel, equipment, and supervision to install units that meet strict technical specifications, including a 1.25-ton capacity, horizontal ceiling-plenum configuration, and the use of low-GWP refrigerants such as R-454B or R-32, as R-410A is strictly prohibited. A critical requirement is that replacement units must fit through existing access openings measuring approximately 3 feet 11.5 inches by 2 feet to avoid structural demolition. The scope of work includes the integration of the units into the central Building Automation System via BACnet IP/MSTP and the use of AHR/ISO 13256-1 certified water-to-refrigerant coaxial heat exchangers. Performance must be completed within 275 days of award. Interested respondents must provide company identification, SAM.gov certifications, and confirmation that technicians hold EPA Section 608 Universal Certifications. Small business prime contractors must also verify they can cover at least 51 percent of the contract cost with their own personnel. Responses are due by October 26, 2026, and must be submitted in PDF format with a maximum length of ten pages, excluding equipment cut sheets.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

6 days ago

DEADLINE

in 6 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS