This Solicitation opportunity from Department Of Energy was posted on November 18, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
Condenser
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
General Info
NAICS
Place of Performance
Menlo Park, CA, 94025, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions
This is a formal request for quotation from Procurement as requirement has been assigned to me as a buyer.
**Please do not contact the requester regarding the item(s) in this request while we are in the process of bidding to maintain the integrity of this solicitation.
Please review the quote and provide your best and final offer for both price and lead-time.
Kindly also have the quotation revised to today’s date and address the quote to my attention.
The follow has been attached for you to complete and review:
- (BAA) Buy American Act Certification
- Representations & Certifications Rider
- Confirm Attached SLAC terms are accepted: FP Commercial Supplies-Services T&Cs (August 2023)
Required item(s) listed below:
- Qty: 1 - product description: Refrigerated Water Re-circulating System; Condenser: condenser water-cooled (heat dissipated into source of water), includes condenser water regulation valve, source water inlet temperature below +75degreeF with max pressure, 100 psi and differential pressure between 25 & 50 psi; Electrical: 208-230V, 3ph, 60Hz; Dimensions: 39”W x 39”D x 70”H.
Quote is for product only; no on-site services permitted.
Source selection will be based on Lowest Price and Technically Acceptable Method (LPTA).
Technical evaluation criteria are as follows:
- Ability to meet the following specs:
Condenser: condenser water-cooled (heat dissipated into source of water), includes condenser water regulation valve, source water inlet temperature below +75degreeF with max pressure, 100 psi and differential pressure between 25 & 50 psi
Electrical: 208-230V, 3ph, 60Hz
Dimensions: 39”W x 39”D x 70”H.
PLC temperature controller with alarm descriptions and logging
Continuous run refrigeration for close temperature control
Hermetically sealed compressor
High supply water temperature system cut out
Regenerative turbine pump with robust seal and bypass relief valve
Integrated fluid tank (non-pressurized) with fluid level switch
Factory tested under full load
Hard process dependency: The SVTA MBE requires a dedicated, tightly controlled process-cooling loop to maintain component temperatures and meet interlock permissives. The specified Haskris unit delivers approximately 20 kW at 60 °F, ≥9.25 GPM, ≥70 psig (100 psig max), with 208 V, 3-phase power at the new location.
Please provide a price and lead time quotation by COB 11/25/2025. (7 days)
Please be advised that the requirement was also posted on SAM.gov.
Send quote to AnthonyC@SLAC.stanford.edu.
The bid closing date for this requirement is 11/25/2025.
Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?
If possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.
- Buy American Act Certification (BAA) applies to awards that are over $10,000.
- Representations & Certifications Rider is required. Once completed the Reps and Certs is valid for one year until renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.
- All subcontractors are required to register in the System for Award Management (www.sam.gov).
- The resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and Conditions for Fixed Price Commercial Supplies and Services (Rev. August 2023) will be made a part of the resulting order.
- Payment Terms will be NET-30
- Freight terms will be FOB Destination Prepaid and Add
- For foreign vendors: Shipment will be made CIP SLAC, Menlo Park, and Duty Unpaid
You are requested to mark and identify proprietary/confidential information provided in response to the solicitation.
Contact me directly with any questions.
Kind regards,
Anthony Chin
Procurement Commodities Team
SLAC National Accelerator Laboratory
2575 Sand Hill Road
Menlo Park, CA 94025
More opportunities from Department Of Energy → Slac National Accel Labor -Doe Contractor
Same awarding agency
Earlier notices in this NAICS code
Posted before this notice, open and closed
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS