Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on August 30, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Cost-Per-Reportable-Result Dimension EXL200 Analyzers

Awarded
N0025922F0161Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334516
New
Federal
Low-Range Force Frame Kit
Solicitation # N6426726R1010
Solicitation N6426726R1010 is a request for proposals for a five-year Indefinite Delivery/Indefinite Quantity (IDIQ) contract to procure Low-Range Force Frame Kits (FFK) for the Naval Surface Warfare Center, Corona Division. The government intends to purchase a minimum of two and a maximum of 45 kits to support Navy fleet Calibration Laboratories. These kits must provide a stable platform for mounting and aligning force gages and dynamometers, adhering to Calibration Standards Specification (CSS) 06-3228 and MIL-PRF-28800G Class 4 environmental standards. Key deliverables include the hardware, a transit case with specific gasket and fastening requirements, COTS operator and service manuals (CDRL T001), and a repairable parts list (CDRL A001). All equipment must feature permanent identification plates and two-dimensional Unique Identification (IUID) data matrices conforming to MIL-STD-130N. The contract will be awarded based on the Lowest Price Technically Acceptable (LPTA) basis, evaluating proposals on total price and a technical rating of acceptable or unacceptable. Technical evaluation includes a review of the offeror's past performance using up to three references from the last three years. Proposals must be submitted electronically via the Procurement Integrated Enterprise Environment (PIEE) portal by October 21, 2026. Required submission documents include a completed Cross Reference Matrix in Microsoft Excel, pricing for all CLINs, and a Small Business Subcontracting Plan for offerors other than small business concerns. Delivery is required within 120 calendar days from the issuance of a delivery order, with shipments sent FOB Contractor Destination.
Naval Surface Warfare Center

POSTED

about 21 hours ago

DEADLINE

in 13 days
NAICS: 334516
New
Federal
Off-Axis Parabolic Mirrors
Solicitation # FA860127Q0003
The Air Force Life Cycle Management Center, on behalf of the Air Force Institute of Technology, is conducting market research via a Sources Sought notice to identify qualified sources for the manufacture and delivery of 66 customized off-axis parabolic mirrors and associated protected-gold coating services. These precision optical components are intended for use in the Extreme Light Laboratory to support ultra-intense laser experiments. The mirrors must feature a 30mm diameter fused-silica substrate with a parabolic focus at 45 degrees, a surface roughness of less than 1nm RMS, and a scratch/dig specification of 20-10. The required protected-gold coating must provide an average reflectivity of at least 97 percent at a wavelength of 780 plus or minus 40nm with a 45-degree angle of incidence. The selected contractor will be responsible for all labor, materials, quality assurance, and transportation to Wright-Patterson Air Force Base, Ohio. Key deliverables include the mirrors and comprehensive test data, including certificates of conformance and surface-measurement data. Delivery is required within 98 calendar days after receipt of order, and the equipment must be warranted against defects for two years following receipt. Payment terms are set at 100 percent after delivery, net 30 days from the invoice date. Interested parties under NAICS code 334516 must submit a capability package by October 23, 2026.
FA8601 Aflcmc Pzio

POSTED

about 21 hours ago

DEADLINE

in 2 days
NAICS: 334516
New
Federal
Flight Model Solar Array Wings
Solicitation # 80NSSC27946791Q
NASA/NSSC is seeking capability statements for the procurement of flight-qualified solar array wings for the TERP RAPTOR 12U CubeSat mission to asteroid Apophis. The requirement includes the acquisition and delivery of one flight model consisting of two solar array wings, each featuring 20 solar cells, hinges, spacers, and a thermal knife deployment system. The scope of work encompasses a comprehensive test campaign involving vibrations, TVAC, and bake-out tests, as well as the delivery of interface documentation, software, and calibration data. The contractor must also provide technical support during solar panel acceptance, spacecraft integration, and initial functional verification at the NASA Goddard Space Flight Center in Greenbelt, Maryland. This procurement is being conducted under FAR Part 12 for commercial items, with a planned period of performance for unit testing and integration from July 1, 2027, through October 31, 2027. While NASA/NSSC intends to issue a sole source contract to DHV Technology under FAR 12.102(a), they are currently requesting capability statements to determine if the procurement should be conducted on a competitive basis. Interested parties must submit their qualifications in writing to the designated point of contact by October 28, 2026. Please note that quotes will not be evaluated at this stage, and all correspondence must reference the notice ID 80NSSC27946791Q.
National Aeronautics And Space Administration

POSTED

about 21 hours ago

DEADLINE

in 7 days
NAICS: 334516
New
Federal
ICP-OES for Oil Analysis
Solicitation # W911S227U0057
Solicitation W911S227U0057 is a Request for Quotation for the procurement of new equipment for the material analysis lab at Yuma Test Center, specifically an Inductively Coupled Plasma-Optical Emission Spectrometer (ICP-OES) and a compatible autosampler. The ICP-OES must feature a radial torch with radial view, oxygen burn capability, chiller-free operation, and the ability to integrate a Catech ASXpress system and export data via .csv for LIMS entry. The autosampler must include a mixing or stirring head, a sample induction head, and a capacity for up to 384 samples across four 96-position test tube racks, with dimensions not exceeding 20 by 24 by 24 inches. Both items must be designed to meet ASTM D-5185 and Caterpillar SOS program performance standards. This acquisition is a Total Small Business Set-Aside under NAICS code 334516, managed by the W6QM Micc-Ft Drum. Award will be granted to the responsible offeror whose proposal is most advantageous to the government, based on an evaluation of price and technical factors. Only new equipment will be accepted; used or remanufactured products are prohibited. Offers of equal products must provide brand names, model numbers, and descriptive literature to prove compliance with salient characteristics. Delivery is required F.O.B. destination, with a preferred timeframe of 30 days. Quotes must be submitted through the PIEE Solicitation module by November 14, 2026.
W6QM Micc-Ft Drum

POSTED

about 21 hours ago

DEADLINE

in 24 days
NAICS: 334516
New
International
HIGH THROUGHPUT SIMULTANEOUS DYNAMIC VAPOR SORPTION (DVS) ANALYSIS SYSTEM
Solicitation # 26-58161
The National Research Council Canada is soliciting offers for the supply, delivery, and installation of a high throughput simultaneous dynamic vapor sorption (DVS) analysis system for its Clean Energy and Innovation facility in Mississauga, Ontario. This system will be used to characterize and quantify the adsorption and desorption behavior of advanced materials, including battery materials such as anodes and cathodes, CO2 capture sorbents, and catalysts for hydrogen production and carbon conversion. The contract includes three primary lump sum deliverables: the DVS system with associated software and accessories, installation, and onsite training. The equipment must be delivered within 10 weeks of contract issuance, with installation completed within 120 days of the award. Specifically, installation must begin within 14 days of delivery and be completed within seven calendar days of the start date, followed by onsite training within 14 days of installation. All electrical equipment must be certified according to the Canadian Electrical Code, Part 1. The award will be based on the lowest evaluated price among offers that meet all mandatory technical criteria. Payment is structured upon the completion and acceptance of deliverables, with the provision that accepted equipment may be invoiced prior to the completion of installation and training. The delivery term is Delivered at Place (DAP) Mississauga, ON, Incoterms 2020. Offerors must submit separate electronic technical and financial proposals by October 28, 2026, ensuring compliance with environmentally preferable packaging specifications and the Canada Procurement Code of Conduct.
National Research Council of Canada

POSTED

1 day ago

DEADLINE

in 7 days
NAICS: 334516
New
SLED
Laboratory Equipment, Microscope & Accessories (Supply and Install) (Echo Revolve)
Solicitation # 40-27
Solicitation 40-27, issued by the New Hampshire Department of Administrative Services, seeks bids for the supply, delivery, and turn-key installation of an Echo Revolve R4 Upright Microscope and associated accessories for the NH Department of Fish and Game in Concord, New Hampshire. The required equipment is a hybrid fluorescence microscope capable of flipping between upright and inverted modes, featuring a 12.9-inch iPad Pro Retina display. Key deliverables include the microscope system, specific LED light cubes, various objective lenses, an ELWD universal condenser, stage inserts, and a digital haze reduction software module. The successful vendor must complete delivery and installation within 45 business days of the contract award. The contract will be awarded to the responsible vendor who submits a conforming bid meeting all technical specifications at the lowest total cost. Bids are due by October 23, 2026, and must be submitted via email to the Bureau of Purchase and Property. Vendors are required to provide proof of comprehensive general liability insurance of at least 1 million dollars per occurrence and 2 million dollars aggregate, as well as workers compensation insurance. Environmental guidelines encourage the elimination of PVC and polystyrene and the use of SmartWay transport partners. Payment terms are set at 30 days following the receipt of an itemized invoice after the equipment has been delivered, inspected, and accepted by the agency.
Das Purchasing (statewide Bids & Contracts)

POSTED

1 day ago

DEADLINE

in 2 days

AI Contract Overview

Show more

This cost-per-reportable contract awards the Naval Health Clinic Cherry Point Center the use of two Siemens Dimension EXL 200 Analyzers for general chemistry and immunoassay testing, with a minimum annual workload of 128,540 tests. The agreement covers all reagents, consumables, and comprehensive maintenance for a one-year base period with no option years. The contractor, acting as the Original Equipment Manufacturer, is responsible for installation, validation testing, and ensuring the systems bi-directionally interface with MHS GENESIS. All equipment and supplies must be FDA compliant and delivered at no cost to the government. Maintenance requirements include quarterly preventive maintenance and corrective services with a 24/7 troubleshooting hotline. The vendor must provide on-site response within 24 hours of a trouble call and ensure equipment is operational within 48 hours. The contract mandates strict adherence to OEM specifications, including the provision of UPS units, software updates, and specialized training for technicians. All service activities must be coordinated with the Biomedical Engineering Division, and the vendor is responsible for all costs associated with parts, labor, and shipping to maintain the instruments in full operational condition.

General Info

Contract Value

$214,855.42

NAICS

334516 - Analytical Laboratory Instrument Manufacturing

Place of Performance

Cherry Point, NC, 28533, USA

Set-Aside

NONE

Award Issued Date

Documents

2

SOW - Siemens Dimension EXL 200 Analyzers for NHCCP

PDF, High priority: read this firstsow
High

Limited Source Justification - Dimension EXL 200 Analyzers

PDF, Low priorityjustification-and-authorization
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Award Notice

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Naval Medical Center San Diego Ca
Contacts1 person available
OfficeSAN DIEGO, CA, 92134-5000, USA
Office AddressSAN DIEGO, CA, 92134-5000, USA

Full Description

Show more
Statement of Work The requirement is for a cost-per-reportable contract for two (2) Siemens Dimension EXL 200 Analyzers (SN DR270845 & SN DR270837), Chemistry, reagents, maintenance, and consumables for Naval Health Clinic Cherry Point Center (NHCCP). The contracted shall be capable of performing general Chemistry and immunoassay testing for a minimum annual workload of 128,540 test. The Chemistry Floor analyzers shall be capable of operating in various modes including: continuous, random STAT and batch specimen. The analyzers shall be capable of processing various adult and pediatric test tubes. The Chemistry analyzers will require an external water source (for lab grade water) a drainage tube that will be used with the floor drain for operation. The dimensions for the floor model analyzer shall not exceed 73" L x 36" W. The electrical requirements: 11SV AC 60HZ Single Phase 20A for both instruments that are on a separate dedicated line with 3-wire distribution to the receptacle is required The vendor shall provide installation, validation testing, onsite and offsite user training and preventive maintenance coverage. The vendor shall provide validation of the analyzers, including normal range verification, demonstration of linearity, reportable range, replication studies, recovery studies and establishment of initial control ranges using control materials. Corrective system maintenance coverage shall include response times, as specified in the Statement of Work (SOW). Training shall be provided by the vendor, as specified in the SOW. The system shall bi-directionally interface with the Military Health System (MHS) GENESIS as specified in the SOW. The vendor shall provide two (2) operational and two (2) service manuals, each in English. The contract will have one (1) base year and no option years. The system, including claims made for the product, shall be compliant with Food and Drug Administration (FDA) regulations, with respect to marketing and delivering medical products for use in the United States of America. Contractor shall be an Original Equipment Manufacturer. A 24/7 troubleshooting (support) hotline and next day service for repairs by manufactures representative and quarterly preventive maintenance performed by manufacturer. The instrument daily maintenance shall not exceed 25 minutes a day due to the hours we are open. Reagent and supply will be delivered by manufacturer at no cost. The system, including claims made for the product, shall be compliant with Food and Drug Administration (FDA) regulations, with respect to marketing and delivering medical products for use in the United States of America. Contractor shall be an Original Equipment Manufacturer. A 24/7 troubleshooting (support) hotline and next day service for repairs by manufactures representative and quarterly preventive maintenance performed by manufacturer. The instrument daily maintenance shall not exceed 25 minutes a day due to the hours we are open. Reagent and supply will be delivered by manufacturer at no cost. All supplied items and reagents shall be certified for use with the vendor equipment provided. All supplied items and reagents shall be delivered IAW manufacturer's shelf life recommendations and delivered at no cost. All supplied items and reagents that require special handling (e.g. refrigeration, time sensitive, immediate open, etc.) will be marked in a clear manner with a label that is easily read, understandable, and a minimum of3" x 3" (9 sq. inches). The label will be placed in three (3) or more locations on the container (top & two sides). Supplies/items that require refrigeration will have both the required Celsius and Fahrenheit temperature identified. The contractor shall provide deliveries to the delivery point identified below: Navy Medicine Readiness and Training Command Cherry Point Attention: Laboratory Department BLDG4389 Cherry Point, NC, 28533 Facility Constraints Laboratory Footprint Each instrument will be installed in a separate 73" L x 36" W space and will be set up back to back. These analyzers are floor models and will not be sitting on a bench The facility has floor drainage in which a rubber tub from the instrument is inserted into the drain. The facility has biohazard collection containers which wastes is manual placed in container Due to the small space and our heating/cooling requirements, the instrument must function within the following parameters: Room temperature must be >/= 65 degrees F and 20 % and 80%. Power requirements- 115V AC 60HZ Single Phase 20A for both instruments that are on a separate dedicated line with 3-wire distribution to the receptacle is required. Maintenance The vendor shall provide trained, experienced, English-speaking personnel. The vendor shall provide all labor, tools, diagnostic equipment, software, material, supplies, transportation, parts, and equipment necessary to perform Preventive Maintenance (PM), Calibration (CAL), Safety Testing (ST), and corrective maintenance. The vendor shall provide telephonic communications with the Government to discuss technical matters relating to the performance of this contract. A systems operator shall be made available to answer technical questions regarding system operations and applications. Equipment listed in this contract will be maintained to meet and retain the original equipment manufacturers (OEM) specifications/equipment certification. The vendor shall provide maintenance services Monday through Friday from 0730- 1615 local time, excluding Federal Government holidays as seen at the following site: https://www.opm.gov/policy-data-oversight/pay-leave/pay-administration/fact sheets/holidays-work-schedules-and-pay. This includes annually required performance maintenance. Customer and Technical support should be available by phone 24 hours, 7 days a week. Preventive Maintenance (PM) Services. Normal Business Hour Maintenance Coverage will be Monday through Friday, from 0730-1615 local time, excluding Federal Government holidays. Vendor shall provide full service preventive maintenance. Preventive maintenance shall be performed in accordance to manufacturer's recommendations. The vendor shall perform PM service checks during the base contract period at the manufacturer's recommended intervals. Vendor will also perform PM service checks during each option year at a date and time mutually agreed upon by the vendor and the Government. All test equipment used in the performance of this contract shall be calibrated, as required by the OEM, and shall be in compliance with Joint Commission (JC), OEM, the College of American Pathologist's (CAP), Food and Drug Administration (FDA), and National Institute of Standards and Technology (NIST) standards. Corrective Maintenance Vendor shall provide on-site corrective maintenance from 0730-1615 Local Time, Monday-Friday, to include unlimited service calls. Telephonic technical support shall be available 24 hours per day, 7 days per week. A vendor service technician shall respond via telephone within two (2) hours after receipt of trouble call and provide on-site service within twenty four (24) hours after receipt of trouble call. Equipment shall be repaired and deemed operational within 48 hours. The Government's request for corrective maintenance will be placed by Laboratory personnel, in coordination with Biomedical Engineering Division (BIOMED) personnel, directly to the vendor or its representatives. Corrective maintenance shall be completed during the hours specified in the contract. The vendor's response to requests for service may include telephone consultation with the equipment user/operator and a vendor FSE. Telephone consultation shall: 1) provide instruction in determining operator error; 2) determine the most likely cause of the problem; 3) determine if resolution of the problem requires the dispatch of a FSE; and 4) identify replacement parts likely to be required in order to return the equipment to 100% operational condition as specified by the OEM. The vendor's quoted annual pricing shall be inclusive of all costs including parts, consumables, labor, travel, and shipping. The Vendor shall have and provide to its representatives its own service manuals, specifications, schematic diagrams, and parts lists to assist in the evaluation and/or repair of all equipment included in this contract. The vendor will (shall) provide a UPS for both instruments. Replacement Parts/Upgrades. The vendor and its representatives shall have ready access to unique and/or high mortality replacement parts. All parts supplied shall be compatible with the existing system. In the event that replacement parts require shipment, shipping shall be performed in the fastest reasonable means possible at no additional cost to the Government The vendor shall replace all worn or defective parts necessary to restore the equipment to 100% operational condition as specified by the OEM. Freight, postage, and storage charges associated with shipment and receipt of replacement parts and the return of parts shall be the responsibility of the vendor. All replacement parts shall be new and certified as OEM replacement parts. The vendor shall provide software revisions, updates, and upgrades (field service changes) required by FDA-announced or manufacturer-announced hazards, alerts, or recalls, including those falling under the most recent applicable FDA Compliance Directive, as part of the contract at no additional cost to the Government. Upgrades shall be performed as soon as possible after release, but no later than during the first scheduled PM inspection after release. For any updates that have been identified as critical, or required for the proper operation of equipment, the vendor shall provide installation within 30 days of release regardless of PM schedules. With approval from the Government, the vendor may perform hardware/software upgrades as they become available. Training The vendor shall provide initial on-site operator training to all technicians assigned to the NMRTCCP Chemistry Department prior to the initial use of the equipment. The vendor shall provide a minimum of one (1) operator training at the vendor's training facility prior to the delivery and installation of the equipment. System Interface Requirement The system shall be capable of bi-directionally interfacing with the MHS GENESIS. If the vendor is not already approved to connect to MHS GENESIS bi-directionally, the vendor shall agree to complete any bi-directional interface integration at no additional cost to the Government. Interface integration must be completed prior to final acceptance of the system. Government furnished prope1iy, Materials and Services. The Government will be responsible for maintaining the proper environment, including utilities and site requirements, necessary for the system to function properly as specified by the OEM. The Government will operate the system in accordance with the instruction manual provided by the OEM. The Government will not be responsible for damage or loss due to fire, theft, accident, or other disaster of vendor supplies, materials, or for the personal belongings brought onto Government property by vendor personnel. Vendor Furnished Property and Material. The vendor shall provide all service literature, reference publications, laptop computers and diagnostic software to be used by the Vendor service technicians and as required for the completion of the services in accordance with this contract. Vendor Report Requirements During normal duty hours, vendor FSE personnel shall check-in with the Biomedical Engineering Division (BIOMED) located at Naval Health Clinic Cherry Point, BLDG 438, 1st floor, Room 1423, Phone (252) 466-0112 or (252) 466-0260, upon arrival at the Government site and again prior to departure. The vendor FSEs shall personally notify BIOMED personnel of problems that result in the equipment being left disabled upon their departure. If equipment is left disabled, a method of physical use prevention of the disabled equipment shall be implemented, and the disabled equipment shall be locked out with a letter of intent in compliance with OSHA regulation to prevent any patient hazards. After normal duty hours, vendor FSEs shall notify the Officer of the Day Desk and the systems' operator designated by BIOMED personnel. The vendor shall provide to BIOMED and Laboratory personnel a full service report within two (2) days after completion of all services performed. Each service report shall at a minimum document the following data legibly, in complete detail, and in English: Name of Vendor Contract Number Name of field service technician performing service Vendor log/control number Date, time (beginning and ending), and hours on-site for service call Description of problem reported by user Equipment identification factors to include manufacturer, make, model, serial number and Facility Equipment Control Number (ECN) Itemized description of service performed to include labor and travel costs, parts used, parts cost, parts number/nomenclature, part new or reconditioned, pa1i manufacturer, and problem/corrective action taken or recommended Problem resolution or pending action Total billing cost Signatures: Field Service Technician performing services BMET verifying service rendered (NMRTCCP) In the event that agents/sub-vendors are used in the performance of repairs, said agent shall be identified on the service report by company name, point of contact, and contact information (i.e. telephone number and email) Vendor Responsibility. The vendor shall be responsible for the repair and/or replacement of damaged Government-owned equipment and property, resulting from the negligence of the vendor or its representatives. All such replacement or repair shall be completed at the vendor's expense and shall be inspected to the satisfaction of the Contracting Officer (KO) or his/her appointed representative. Removal of Government Property No equipment shall be removed without the approval of the Contracting Officer's Representative and Materials Management Department (MMD) of the Medical Treatment Facility (MTF). Property passes for equipment removal shall be obtained by the vendor via the MMD of the MTF. Any failure to obtain such passes, which results in detainment or prosecution of service vendor personnel, is the sole responsibility of the service vendor and their personnel The vendor shall provide a detailed description of removed items on the vendor's company letterhead. For associated items/accessories, the vendor shall provide a detailed written description and quantities of items to be removed. Descriptions shall include, at a minimum, the manufacturer's serial numbers and facility equipment control numbers (ECNs) of all equipment/items removed. In the event that items/sub assemblies/accessories are "repaired by replacement", a detailed description of replaced items is to be included upon return of repaired components. No additional charge shall be allowed for work performed off-site, or any additional time required. All charges resulting from a vendor determined requirement to transport Government-owned property, covered by this contract, to and from an alternate repair location shall be the responsibility of the vendor. The vendor shall provide insurance coverage for damage to or loss of equipment while in vendor or service vendor's custody. In regards to patient information confidentiality and privacy, all vendors and/or service vendors shall not remove equipment containing personally identifiable information or patient health information from the Government site. The equipment hard drive (HDD) shall be removed by MTF personnel prior to equipment removal from the site. Furthermore, equipment removed from the MTF will be prorated from the date of removal for service maintenance fees. If HDD are to be replaced, the HDD in disrepair shall be left at the MTF for disposal. Service Beyond the Scope of the Contract The vendor shall immediately, but not later than 24 consecutive hours after discovery, notify BIOMED in writing of the existence of or the development of any defects in the scheduled equipment, for which the Vendor considers they are not responsible for repairing under the terms of this contract. At the same time of this notification, the vendor shall furnish BIOMED with a written estimate of the cost to make the necessary repairs. Repairs considered by the Contracting Officer to be outside the scope of this contract shall not be covered under this contract, but shall be ordered under a separate purchase order.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS