Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, July 8 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Government of Canada was posted on February 23, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

County of Minburn No. 27 - Request for Quotes - 2026 Mannville Station Yard Improvements

Closed
AB-2026-01533Canada

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Government of Canada → County of Minburn No. 27View Agency

NAICS

N/A

Place of Performance

Alberta, CAN

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → County of Minburn No. 27
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → County of Minburn No. 27
View Agency Profile
Office AddressN/A
Contacts
Mike FundytusContracting Authority

Full Description

Show more
The County of Minburn is seeking quotes from qualified contractors to perform some yard improvements at the County fire station located in Mannville. A detailed listing of the specifications, requirements and location are provided as follows: Project Specifications: • Location: Mannville, Alberta • Removal and disposal of existing 30’ x 30’ concrete foundation. There appears to be a water line protruding from the pad on the southwest corner of the existing pad that will need to be removed as well. • Crib, prep and pour new concrete pad 6” thick • Air Entrained 5%-7% • Base comprised of 6” of compacted ¾” crushed angular gravel • 16” o/c 10mm rebar • 10’ x 10’ control joints • Broom finished and sealed • All labor, base and pad materials • Supply and Install chain link fencing • Approximately 500 feet in length, • Terminal/Gate Posts are to be 3 ½ - 4 ½ inches in diameter x 10 feet minimum of appropriate thickness and galvanized • Line posts are to be 2 3/8 inches in diameter x 8 feet of appropriate thickness and galvanized • Line posts are to be augered and set in place with concrete • Top rails are to be 1 5/8 inches in diameter with swedge end x 21 feet of appropriate thickness and galvanized • Post spacing are to be not more than 10 feet apart • Chain Link Mesh are to be 2 inch squares x 9 gauge galvanized fabric x 6 feet high with 3 strand barb wire on top • Two gates with the following dimensions: - 30 foot cantilevered - 4 foot man gate • All required supplies, manpower and equipment to finish the installation. Please see documentation for more information.