This Solicitation opportunity from Department Of Defense was posted on October 12, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
COUPLING, TUBE
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
Solicitation SPE7M4-27-T-0638, issued by the DLA Weapons Support Fluid Handling Division, is a request for quotations for the procurement of tube couplings identified by NSN 4730-00-283-6399. The items must be manufactured from Titanium AMS 4965 and feature a nominal .375 inch tube outer diameter. This is a restricted source item that must be manufactured according to OEM drawings; any offers based on alternative manufacturers must provide sufficient technical data for evaluation. The total requirement consists of 44 units, split between CLIN 0001 for 14 units and CLIN 0002 for 30 units. Delivery is required within 84 days after receipt of order, with shipments directed to DLA Distribution Depot Oklahoma and DLA Distribution Warner Robins. The contract is categorized as a commercial item under NAICS code 332996 and incorporates a HUBZone price evaluation preference. Technical and quality compliance is governed by the DLA Master List of Technical and Quality Requirements (RA001), with packaging adhering to ASTM D3951 and RP001, and marking following MIL-STD-129. Inspection and acceptance will occur at the destination. Administrative requirements include the use of the Wide Area WorkFlow (WAWF) system for electronic invoicing and payment. The solicitation also mandates compliance with various FAR and DFARS clauses, including the Buy American Act, Berry Amendment, and NIST SP 800-171 cybersecurity assessment requirements.
General Info
Place of Performance
3301 F AVE CEN REC BLDG 506 DR 22, TINKER AFB, OK, 73145-8000, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
COUPLING, TUBE. TITANIUM AMS 4965 6AL
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RQ002: CONFIGURATION CHANGE MANAGEMENT ENGINEERING CHANGE PROPOSAL
REQUEST FOR VARIANCE (DEVIATION OR WAIVER)
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
4V. NOMINAL .375 INCH TUBE OD.
THIS ITEM IS IDENTIFIED AS A COMMERCIAL ITEM (TO INCLUDE 'COMMERCIAL
OF A TYPE')
NOTE: THIS IS A RESTRICTED SOURCE ITEM
MANUFACTURED TO THE OEM DRAWING(S) CITED
HEREIN AND AS OF THE DATE OF THIS SOLICITATION
ONLY THE SOURCE(S) CITED BELOW HAS/HAVE BEEN
PREQUALIFIED TO MANUFACTURE THE ITEM.
OFFERS BASED ON SUPPLYING OTHER MANUFACTURER'S
PARTS SHALL BE ACCOMPANIED BY TECHNICAL AND
OTHER DATA SUFFICIENT TO EVALUATE THE ITEM FOR
THE INTENDED APPLICATION AS PER DLAI 3200.1,
ENCL 6. SAID NSN/Part Number: 4730-00-283-6399 Quantity: 14 EA Purchase Request: 7018682569QTY: 44 Delivery: 84 days ADO
More opportunities from Department Of Defense → DLA WEAPONS SUPPORT FLUID HANDLING DIVISION
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS
