Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on March 18, 2020. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

CRYO PUMPS for the Multi Scale rocket Engine Test Facility, Edwards AFB AFRL

Closed
FA9300CRYOPUMPSFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Agency

Department Of Defense → FA9300 Aftc Pzr

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Edwards, CA, 93524, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Deadline changed

Response deadline changed from Mar 19, 2020 to Mar 25, 2020.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA9300 Aftc Pzr
Contacts2 people available
OfficeEDWARDS AFB, CA, 93524-1185, USA
Organization / Agency
Department Of Defense → FA9300 Aftc Pzr
Office AddressEDWARDS AFB, CA, 93524-1185, USA

Full Description

Show more
This Request for Information (RFI) is issued as market research. All requirements identified in this RFI are tentative and will be finalized prior to the release of any solicitation. The Government does not intend to award a contract or purchase order in response to this RFI or otherwise pay for the information submitted. The information provided is entirely voluntary and will not impact the ability to bid on future requirements. This RFI is for planning purposes only and shall not be considered a request for proposal (RFP), request for quote (RFQ), or as an obligation on the part of the Government to acquire any products or services. The information provided may be utilized by the Air Force Research Laboratory (AFRL) in developing its acquisition strategy should a decision be made to proceed with acquiring the items/services listed in this RFI. The information received in response to this RFI may be included in one or more future solicitations. The results of this RFI will assist in making the determination of whether or not this acquisition will be full and open or set aside for small business competition. All responses shall include the following information: 1. Company Name 2. Business Size for subject NAICS 3. Cage Code 4. Details on which line items your company is able to provide and any applicable restrictions AFRL is seeking U.S. sources with the capability to provide the items/services listed in this RFI. Responses are limited to 20 pages. All replies are to be provided to the Contracting Specialist, Alvaro Guzman, alvaro.guzman.1@us.af.mil and the Contracting Officer, 1Lt. Andrew Ermitano, andrew.ermitano.1@us.af.mil. All responses to this RFI must be received NO LATER THAN Thursday, March 19, 2020 at 16:00 p.m. PST. ***** CRYOGENIC OXYGEN COMPATIBLE PUMPS must meet the following requirements***** The Multiscale Rocket Engine Test (MRET) Facility is in need of cryogenic, oxygen compatible pumps. These pumps must meet the following requirements Liquid oxygen compatible (may require remote panel) Able to pump 2 GPM of LOX Inlet conditions: 10 psi, -320'F (approximate) Outlet conditions: 10,000 psi Electrically powered, 3-phase, 460-480VAC, 60 Hz, 40HP Sealed, etc for outdoor service Automated chill-in sequence Remote operation & PLC control (send on/off signal and pump manages itself) Inlet connection NPT (preferred, Medium pressure acceptable), Outlet connection medium pressure (at least ) Sufficient channels of pressure and temperature output to monitor pump operation and health during operation Additional safety features Relief vale with set point of 11,000 psi Automated pump cooldown monitoring (vapor return temperature) Integrated protection for discharge cavitation and pump seal leak Local e-stop Visible fault active indication (light stack preferred) Redundant shut down Nema-4 enclosure

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS