This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on May 11, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Culvert

Closed
W911S226U3116Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract involves the fabrication and installation of a box culvert measuring approximately 5 feet in span, 6 feet in rise, and 51.7 feet in length, consisting of eight sections. The scope includes cutoff walls at both culvert ends and four cantilever L-shaped wingwalls, each 8 feet long. Additionally, two headwalls, each 1 foot wide and 1 foot high, will be installed at the ends of the culvert. Neoprene gaskets will be applied to each box section before delivery to ensure tight sealing, while exterior waterproofing will be handled separately. The culvert design meets HL-93 live load rating requirements with New York Professional Engineer (PE) stamped drawings and supporting calculations. It is designed to accommodate Class 100 tracked and Class 120 wheeled vehicles according to UFC 3-310-08 standards. The culvert will be installed with a 24-degree skew relative to the road alignment. This contract is a total small business set-aside under NAICS code 331210 and is being managed by the Department of Defense at the W6QM MICC office, Fort Drum, NY. The solicitation was posted on May 11, 2026, with a response deadline of May 13, 2026. Interested parties can direct inquiries to the primary point of contact, Carrie Lawton, and full contract details are accessible through the SAM.gov online workspace. The contract encompasses both supply and installation components, with all engineering documentation professionally certified to ensure compliance with specified load and durability standards.

General Info

Fabrication and installation of 5x6x51.7 ft box culvert with wingwalls, sealed sections, and PE-certified design.

Agency

Department Of Defense → W6QM Micc-Ft Drum

NAICS

331210 - Iron and Steel Pipe and Tube Manufacturing from Purchased SteelView NAICS

Place of Performance

4525 Camp Hale Rd Fort Drum, NY 13602 , NY, 13602

Set-Aside

SBA

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

1 update
PhaseClosed
Posted

Combined Synopsis

Amendment 1

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QM Micc-Ft Drum
Contacts1 person available
OfficeFORT DRUM, NY, 13602-5220, USA
Organization / Agency
Department Of Defense → W6QM Micc-Ft Drum
Office AddressFORT DRUM, NY, 13602-5220, USA
Contacts
Carrie Lawton

Full Description

Show more
5? wide x 6? high x 51.7? length Box Culvert to include: Approximately (51.7) Lineal feet of 5? (span) x 6? (rise) I.D. of Box Culvert (8sections).Cutoff Walls for (2) Culvert ends and (4) wingwalls. (4) L-shaped cantilever wingwalls 8?long. (2) Headwalls, one at each end 1? wide x 1? high on each end section. Neoprene gaskets will be installed on each box section prior to delivery. Exterior waterproofing by others. Level 1 black bar reinforcing carried. HL-93 Live Load Rating assumed (NY PE stamp w/ supporting Calculations provided). Class 100 Tracked and Class 120 Wheeled in accordance with UFC 3-310-08 in attached PDF. Skew angle of the culvert with the road will be 24 degrees. Drawings/submittals stamped by a PE licensed in NY with supporting engineering.