Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on September 23, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

DC VAMC BIOMED INDUSTRY DAY OCTOBER 29, 2025

Closed
36C24525Q0857Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Washington, DC, 20422, USA

Set-Aside

NONE

Documents

1

DC VAMC BIOMED Industry Day - Ceiling Lifts (36C24525Q0857)

DOCX, Low priorityindustry-day
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

event

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Office AddressLINTHICUM, MD, 21090, USA
Contacts
Kenneth Dougherty

Full Description

Show more
An in-person Industry Day for the Veterans Health Administration (VHA) is scheduled for October 29, 2025, from 10:00 am - 5:00 pm est. The event will be held at the Washington DC Veterans Affairs Medical Center located at 50 Irving St. NW, Washington DC 20422. This event will focus on the identification of commercially available ceiling lifts which will be compatible with the existing system in use at the Washington DC VAMC. The event will consist of introductions of relevant VA staff; tour of the Washington DC VAMC which will provide vendors with the opportunity to see existing ceiling lifts and ceiling tracks; and followed by 30-minute, one-on-one meetings between the government and vendors. The one-on-one meetings will provide the government to ask questions of the vendors; examine vendors equipment, if applicable; and dialogue. The event will provide the VA's clinicians and biomedical engineers with information regarding industry's ability to provide ceiling lifts compatible with the existing track system and with the following salient characteristics. Ceiling Lift Salient Characteristics: Rail Compatibility: Compatible with existing single-rail and H-rail track configurations used in our facility Powerful Motorized System: Features a powerful, motorized system that allows for smooth vertical and horizontal patient transfers, including a minimum lifting capacity of 600 lbs. The motors must have an expected lifespan of at least 10 years. Lifting Speed: Must have a minimum lifting speed of 1.5 inches/second when lifting a load of at least 400 lbs, with a preferred soft/slow start and stop. Hand-Held Remote: Includes an easy-to-use hand-held remote control for caregivers to operate the lift seamlessly. The hand control must be wired. Safety Mechanisms: Equipped with numerous safety mechanisms such as emergency stop and lowering functions (without the need for an Allen wrench), overload protection, and compliance with relevant health and safety certifications and standards for medical equipment. Slings and Accessories: Compatible with various slings and lifting accessories to meet different patient care needs. Quiet Operation: Designed to operate quietly, reducing noise for a more comfortable patient experience. Durability and Maintenance: Engineered for durability and easy maintenance, ensuring reliability over the long term. Ergonomics: Ergonomically designed to minimize strain on caregivers while ensuring patient comfort and safety. Lifting Range: Substantial vertical lift range to accommodate transfers from different surfaces like beds and chairs (~8ft). Battery Operation: Battery-operated with rechargeable batteries that continuously charge anywhere on the track via AC charging, meeting minimum requirements: If NiMH - must have 2 - 24V NiMH, 2.1Ah. If Lead Acid - must have a minimum of 12V, 5Ah, sealed rechargeable valve regulated. Electrical Data: Rating 24 V DC, 15 A max. Staff Training: Comprehensive training program for hospital staff on the proper use, care, and maintenance of the ceiling lift system. Infection Control: Easy-to-clean surfaces and components designed to minimize infection risk. Scales: Scales must be included for each motor with a minimum weight capacity identical to the lift motor for the purposes of weighing Veterans. Performance Assurance: The supplier must provide lift systems from a manufacturer that is not currently undergoing assessment, investigation, or evaluation by the National Center for Patient Safety related to performance events. Vendors interested in attending this event must take following actions and provide the following information: Company Name: SAM ID: Primary Point of Contact: Point of Contact Email: Company Website: Socioeconomic Status (if applicable): Compatible Equipment Model(s): Product Literature, Brochures, and/or Capabilities Statement: GSA Contract Number (if applicable): Vendors interested in attending this event must respond to this notice by emailing contact@example.gov no later than October 3, 2025, at 4:00 pm eastern. Additional Notes: Only vendors who provide the requested information by the suspense date of October 3, 2025, will be permitted to attend this event. Selected respondents to this notice will be notified by the government and provided additional event information needed to attend.

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 561730
New
Federal
Snow and Ice Removal Management Services
Solicitation # 36C24527Q0041
The Department of Veterans Affairs is soliciting quotes for on-call, 24/7 snow and ice management services at the Beckley VA Medical Center in West Virginia. The contract period of performance runs from November 1, 2026, to April 30, 2027. The selected contractor will be responsible for providing all labor, equipment, and materials to perform plowing, clearing, deicing, pre-treatment, and snow relocation across approximately 11 acres, including roads, parking lots, garages, sidewalks, and emergency access routes. Services must follow a three-tier priority scheme to ensure continuous vehicular and pedestrian access, with a strict prohibition on using sodium chloride on parking garage decks and ramps. This is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). Award decisions will be based on a comparative evaluation of technical capability, past performance over the last three years, and pricing reasonableness, rather than a low-price technically acceptable process. Offerors must submit their proposals by October 29, 2026, at 3:00 PM EST. Key requirements include continuous monitoring of the National Weather Service, submission of Safety Data Sheets for all deicing products, and adherence to Service Contract Act wage determinations for West Virginia. Invoicing must be processed electronically via the FSC e-Invoice Payment system.
Landscaping Services

POSTED

1 day ago

DEADLINE

in about 2 hours
View Details
NAICS: 561210
New
Federal
J044--NOTICE OF INTENT TO SOLE SOURCE Baltimore VAMC Steam System Preventive Maintenance from Vicinity Energy Baltimore Corporation
Solicitation # 36C24527Q0048
The Department of Veterans Affairs is issuing a Notice of Intent to Sole Source for an open market award to Vicinity Energy Baltimore Corporation to provide annual steam system preventive maintenance at the Baltimore VA Medical Center. This requirement, classified under NAICS code 561210 and PSC J044, is driven by the fact that the facility's steam equipment is directly connected to the district steam distribution system owned and operated by Vicinity Energy. Due to this interconnected configuration and the proprietary operational data involved, the government identifies Vicinity Energy as the sole source capable of ensuring the reliable operation of the system without risking the broader distribution network. The scope of work requires a two-person crew to provide eight hours of service every two weeks, totaling 416 labor hours per year. Key responsibilities include steam trap surveys, cleaning pressure-reducing valves, inspecting heat exchangers, and ensuring proper water chemistry and meter operation. The contractor must supply all necessary parts meeting original manufacturer specifications and provide emergency call-back services with a technician on-site within five hours of notification. The anticipated period of performance is one year from the award date, with the possibility of option-year extensions. Interested vendors may submit capability statements to Contract Specialist Patricia Thai by 11:00 AM EST on November 10, 2026, referencing announcement number 36C24527Q0048. These submissions will be used solely to determine if the procurement will be conducted on a competitive basis. All work will be performed at the Baltimore VAMC, adhering to strict VA security, safety, and infection control requirements.
Facilities Support Services

POSTED

1 day ago

DEADLINE

in 12 days
View Details
NAICS: 423440
New
Federal
J072--JR/BP POTS AND PANS ROOM | WASHINGTON DC VAMC
Solicitation # 36C24527Q0043
The Department of Veterans Affairs is seeking a contractor for the emergency procurement, delivery, and factory assembly of commercial-grade kitchen equipment for the Nutrition and Food Services Pot and Pan Washing Room at the Washington DC VA Medical Center. This firm-fixed-price acquisition is driven by critical infection control and physical environment deficiencies identified during a June 2026 Joint Commission survey. The required equipment includes a custom Aerowerks two-compartment sink system with a drainboard, a Salvajor food waste disposer, and a Hobart TurboWash II pot scrubber. All equipment must be NSF listed, commercial grade, and compliant with Joint Commission, CMS Conditions of Participation, and FDA Food Code standards. The contractor is responsible for freight, uncrating, and delivery to the facility within 60 calendar days of award. A qualified Aerowerks technician must perform the on-site assembly within 14 days of delivery to preserve the manufacturer warranty. Strict safety and cleanliness protocols are in effect, including the requirement for hot work permits for welding and the immediate removal of all packaging and metal debris to prevent food service contamination. Payment will be issued via a single electronic invoice on a Net 30 basis following the COR's written acceptance of the installed and inspected equipment.
Other Commercial Equipment Merchant Wholesalers

POSTED

3 days ago

DEADLINE

in 6 days
View Details
NAICS: 238210
New
Federal
J061--INTENT TO SOLE SOURCE AWARD TO EATON CORP - BASE YEAR MAINTENANCE AND SERVICE CONTRACT FOR 8 UPS HERSHEL WOODY WILLIAMS VAMC
Solicitation # 36C24527Q0046
The Department of Veterans Affairs intends to award an open market sole source contract to Eaton Corporation (UEI: NP3NSFVMNUM3) for a one-year service and preventative maintenance agreement. The contract covers eight specific Eaton UPS systems located at the Hershel Woody Williams VA Medical Center in Huntington, West Virginia. The scope of work includes a Flex Plan consisting of two UPS and two battery preventive maintenance checks for all eight systems. This procurement is classified under NAICS code 238210 for Electrical Contractors and Other Wiring Installation Contractors and PSC J061 for the maintenance and repair of electric wire and power distribution equipment. The government is pursuing a sole source award because Eaton Corporation is the original equipment manufacturer and the only authorized provider of the proprietary service software, repair documentation, and materials required for 3-phase Eaton UPS products. As an ISO9001 certified supplier, Eaton does not certify or support third-party providers for these specific products. This notice is published in accordance with FAR 5.101(a) and FAR 12.102. Interested vendors may submit capability statements to Contracting Officer William Pratt by November 12, 2026, at 10:00 AM ET, referencing announcement number 36C24527Q0046 to determine if the requirement will be competed.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

3 days ago

DEADLINE

in 14 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS