Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 19 at 2:00 PM EDT

Register Free →

Development Plan Amendment, Conditional Use Permit Amendment, and Addendum for the Goleta Energy Storage to add battery Augmentation Units ("GES Augmentation Un

Awarded
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

California → City of Goleta

NAICS

238210 - Electrical Contractors and Other Wiring Installation ContractorsView NAICS

Place of Performance

Cortona Drive and Hollister AVenue, Santa Barbara, CA, 93117

Set-Aside

NONE

Documents

(1)

Notice of Determination for Goleta Energy Storage Project Amendment

PDFnotice-of-determination

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseAwarded
Posted

forecast

Awarded

Contract was awarded

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → City of Goleta
Contacts3 people available
OfficeN/A
Organization / Agency
California → City of Goleta
Office AddressN/A
Contacts
Lisa PrasseCurrent Planning Manager
Selena WhitneyProject Manager
Paul ZavesoffVice President of Assest

Full Description

Show more
Full Title: Development Plan Amendment, Conditional Use Permit Amendment, and Addendum for the Goleta Energy Storage to add battery Augmentation Units ("GES Augmentation Units"); Case Nos. 24-0008-DP(AM) and 24-0003-CUP (AM). NOD associated with an Addendum to a previously approved IS/MND for a 60 MW battery storage facility. The Addendum analyzes the impacts of adding 132 battery augmentation units to the existing site over time. The augmentation units are necessary to maintain the energy goals of the project for the long term and meet the power supply contract requirements of SCE. The GES augmentation units will not have a more significant effect on the environment than previously identified in the adopted IS/MND. Further findings were made pursuant to PRC section 21166 and State CEQA Guidelines section 15162 relating to the subsequent environmental review The Amended Project includes the installation of up to 132 Powerpack 3 augmentation units. The Powerpack 3 augmentation units would be installed on existing concrete pads immediately adjacent to the existing Megapacks. The augmentation units would measure approximately 3.5 feet (43 inches) wide by 5.9 feet (71 inches) deep by 8.25 feet (99 inches) tall and would match the existing Megapack color. One Powerpack includes three independent battery modules. The installation of the 132 Powerpack units would occur in installments of up to 40 units placed at a time. Each installment would take place over a maximum of 30 days. Thus, the construction period for the Amended Project would occur in three to four phases, lasting up to 30 days each. The augmentation units would be necessary to maintain the energy goals of the project for the long term and meet the power supply contract requirements of Southern California Edison for the approved 60 MW facility. The augmentation units are required as part of the Capacity Maintenance Agreement between Tesla and the Property Owner. The installation of the augmentation units was previously contemplated for the Approved Project, but the units were not included nor analyzed in the Approved Project's CEQA review. The concrete pads required to support the augmentation units were part of the Approved Project and have been installed. Therefore, this current request involves City review and approval for placement of the augmentation units on the existing concrete pads located at the Approved Project site.

Similar Contracts

Same NAICS industry code

NAICS: 238210
New
Replacement Fiber Line
Solicitation # Replacement Fiber Line
The contract involves the replacement of existing multimode fiber optic cabling with 12-strand single mode fiber optic cabling connecting Building 2436 to Building 2443 at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope requires full provision of labor, equipment, and tools to remove retired multimode aerial fiber lines and splice boxes from utility poles and building infrastructure, and to install new 12-strand single mode aerial fiber using center-owned utility poles between the network closet in Building 2436 and the Maintenance office in Building 2443. Specific hardware must meet or exceed Belden product specifications including FS3L0024NS OS2 OSP fiber, ECX-01U rack-mounted enclosure, FFSX12LD adapter panel, and FTSLC900FS01 fiber connectors, with SFPs to be provided by Job Corps. The work is structured as a fee-for-service contract with a lump sum pricing model, and the contractor must submit a detailed bid sheet along with supplemental documentation including a W-9, self-certification form, and acceptance of terms. All submissions must be emailed by 3:00 PM CST on August 10, 2026, to the designated point of contact. The contract enforces compliance with multiple Federal Acquisition Regulation clauses including Service Contract Labor Standards with Wage Determination WD#2015-4687 (Rev 31), Contract Work Hours and Safety Standards Act, and Reporting Executive Compensation. Subcontractors with agreements exceeding $30,000 must disclose debarment status under FAR 52.209-6. The contractor must be a qualified small business as defined under NAICS code 238210 with a size standard of $19.0 million, and eligible set-asides include small business, small disadvantaged business, women-owned, HUBZone, veteran-owned, and service-disabled veteran-owned small businesses. Mandatory insurance requirements include $1 million per occurrence and $3 million aggregate general liability coverage with MTC listed as additional insured, $1 million auto coverage, and $500,000 workers’ compensation. The contractor is required to indemnify MTC against all claims arising from performance or negligence, comply with the Drug-Free Workplace Act and Anti-Kickback Act, and adhere to strict data breach reporting protocols requiring notification to the Department of Labor within one hour of
Earle C. Clements Job Corps Center

POSTED

about 12 hours ago

DEADLINE

in 3 days
View Details
NAICS: 238210
New
AEA-0536, VORTAC (ART) Doppler Conversion, Watertown, NY
Solicitation # aea-0536-vortac-art-doppler-conversion-watertown-ny
The FAA is upgrading an existing VHF Omnidirectional Range facility in Watertown, New York, to a modern Doppler VORTAC system with an offset TACAN, requiring complete demolition of the current infrastructure and new construction of a fully integrated navigation facility. The new Doppler VORTAC will include a 37’x37’ steel building with a 60-foot diameter counterpoise integrated into the roof, along with all necessary foundations, site development, and utility connections. Additionally, an offset TACAN component will be built as a standalone 16’x16’x20’H steel tower with its own foundation, site preparation, and utilities, positioned separately from the main VORTAC structure to ensure optimal signal performance and operational redundancy. This contract, solicited under AEA-0536, is designated for small business set-asides, including categories such as Small Disadvantaged Businesses, Women-Owned Small Businesses, HUBZone, Veteran-Owned, and Service-Disabled Veteran-Owned Small Businesses, reflecting a commitment to diverse contractor participation. The solicitation was posted by PTSI Managed Services, Inc. operating under Parsons, with a response deadline on August 28, 2026, and the work will be performed in New York. Angela Stydinger of the FAA is the designated point of contact for inquiries, and the project falls under NAICS code 238210 for site preparation and specialized trade contractors.