Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

ECEP Cooling Tower Basin Improvements

Active
ITB # C007159State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

N/A

Place of Performance

Epcot Energy Plant - Spark Conference Room 751 Backstage Lane Lake Buena Vista, FL 32830, CA, USA

Set-Aside

NONE

Documents

25

Central Florida Tourism Oversight – Specific Safety Plan Requirements

PDF, High priority: read this first3 pages · sow
High

CFTOD Insurance Requirements v. 12.25

PDF, High priority: read this first2 pages · insurance-requirements
High

Conflict of Interest and Public Entity Crime Affidavit

PDF, High priority: read this first2 pages · conflict-of-interest-affidavit
High

RCES Contractor Safety Expectation - Confined Spaces

PDF, High priority: read this first3 pages · specifications
High

RCES Electrical Construction Specifications Revision 4 09-09-2022

PDF, High priority: read this first667 pages · specifications
High

RCES Lock Out Tag Out (LOTO) Program

PDF, High priority: read this first10 pages · specifications
High

Affidavit of Eligibility Form - Buy Local or Veteran Small Business Program

PDF, Low priority1 page · affidavit
Low

Affidavit of Eligibility Form - Opportunity Zone Program v12.25

PDF, Low priority1 page · form
Low

Foreign Countries of Concern and Human Trafficking Affidavit

PDF, Low priority1 page · affidavit
Low

Bidder Requirements Checklist v.3.pdf

PDF

Cooling Tower Basin Photos.pdf

PDF

Directions to EPCOT Central Energy Plant 751 Backstage Lane Directions v.12.25.pdf

PDF

EPCOT Cooling Tower Improvement Drawings - Line Stops and Valve Sequencing.pdf

PDF

Exhibit B - EPCOT Cooling Tower Improvement Specifications.pdf

PDF

Exhibit C - EPCOT Cooling Tower Improvement Drawings (revised 10-22-2026).pdf

PDF

Inside Plant Photos.pdf

PDF

ITB Exhibit A - Scope of Services.pdf

PDF

M301.pdf

PDF

M402.pdf

PDF

Mandatory Pre Bid Meeting Sign in Sheet.pdf

PDF

Project Reference Form v.12.25.pdf

PDF

SAMPLE - Construction Agreement (Bond Required).pdf

PDF

Second Mandatory Pre Bid Meeting Sign in Sheet.pdf

PDF

Subcontractor List v.12.25 (1) (1).pdf

PDF

Warranty Offered Form (1).pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

Posted

Contract opportunity posted

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → Utilities Services Department of Central Florida Tourism Oversight District
Contacts1 person available
OfficeCA, USA

Full Description

Show more
Scope: The scope of work for ECEP Cooling Tower Basin Improvements includes, but is not limited to:A.     Provide and Install sluice gates at (3) existing basin openings in between cooling tower cells 3 and 4B.      Provide and Install a 24" CWR bypass pipe between the north side header to the south side headerC.     Provide and Install butterfly valves at the connection to the existing north header and at the connection to the existing south headerD.     Replace the pneumatic actuators with electric actuators on the existing cooling tower inlet valves for Cooling Towers 1,2, and 3E.      Replace the butterfly valve and pneumatic actuator with an electric actuator at the tower inlet for Cooling Tower 4F.      Provide and install isolation butterfly valves in the main condenser water header between the takeoffs for CT-1 and CT-2, between the takeoffs for CT-2 and CT-3, and between the takeoffs for CT-3 and CT-4G.     Provide and install solenoid valves at the chemical treatment discharge pipes for each cooling tower basinH.     Provide control modifications for operation of the sluice gates, tower isolation valves, header isolation valves, and chemical treatment discharge valves
Notes: The basis of award shall be the lowest responsive and responsible bidder based on the combined total price of base bid items.
Bid Bond: 5.00%

More opportunities from California → Utilities Services Department of Central Florida Tourism Oversight District

Same awarding agency

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS