Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Subcontract opportunity from California was posted on August 5, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Electrical and Lighting Installation

Closed
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238210
New
Inland Empire Job Corps-Request for Quote Electrical Repairs
Solicitation # inland-empire-job-corps-request-quote-electrical-repairs
Management & Training Corporation is seeking a subcontractor to perform electrical and fire alarm repairs at the Inland Empire Job Corps Center in San Bernardino, California. The scope of work includes correcting GFCI open-ground conditions in the Dormitory and Medical areas, installing filler plates in panelboards, and correcting deficiencies for specific panelboards including KL2A, PF, C, and H1. Additionally, the contractor must update and label circuit directories for Panelboards M, R, C, A, K, and K1. All work must adhere to the National Electrical Code, NFPA standards, and applicable federal, state, and local requirements. The solicitation is open to various small business categories, including SBA certified Veteran-Owned, Service-Disabled Veteran-Owned, Women-Owned, and HUBZone small businesses. Bidders must submit a lump sum fee bid and provide essential identification details, including a Tax ID, DUNS number, and Unique Entity Identification number. Key requirements include maintaining general liability insurance of at least 1 million dollars and worker's compensation with employer's liability limits of 500,000 dollars. Compliance with FAR regulations regarding the Buy American Act, trafficking in persons, and whistleblower rights is mandatory, and first-tier subcontractors with awards exceeding 45,000 dollars must disclose any federal debarment or suspension status.
Inland Empire Job Corps

POSTED

about 4 hours ago

DEADLINE

in 7 days
NAICS: 238210
New
26-140 Installation of Emergency Shut Off Switches
Solicitation # 26-140
Solicitation 26-140 is a subcontracting opportunity with Atterbury Job Corps Center, operated by Adams and Associates, Inc. for the U.S. Department of Labor, to install emergency shut-off switches on power tools in the Facility Engineering Storage/Maintenance Shop in Edinburgh, Indiana. The scope of work requires the installation of two mushroom-head push-button emergency shut-off switches and a new 60A, 208/120V, 3-phase, 4-wire, 6-circuit branch circuit panel with a 60A shunt-trip main circuit breaker. All work must comply with OSHA, EPA, and FNC guidelines, as well as state and local codes, with Indiana regulations prevailing if they are more stringent than federal requirements. Deliverables include the completed installation, training, operating and maintenance manuals, keys, manufacturer warranties, and a one-year guarantee of workmanship. The procurement is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications. A mandatory site visit was scheduled for November 10, 2026, with a proposal deadline of November 20, 2026. Bidders must submit a single lump sum contract bid on company letterhead, including a detailed cost breakdown, a timeline for substantial completion, and proof of a valid Indiana Contractor's License. Award will be based on best value, evaluated across price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Required insurance includes general liability of at least 1 million dollars per occurrence and automobile liability. Payment terms are Net 30, and final payment is contingent upon the submission of a completed SF 1413, certified payroll records, and the release of liens.
Atterbury Job Corps. – Adams & Associates

POSTED

about 4 hours ago

DEADLINE

in 14 days
NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency is soliciting proposals under RFP-VC-26-010 for professional transformer oil testing services to enhance the reliability, safety, and maintainability of its transformers. The scope of work is divided into three primary areas: conducting visual and infrared thermographic inspections of energized transformers to identify thermal anomalies, installing standardized external oil sampling devices to improve safety and access, and performing comprehensive oil testing analysis. The selected contractor must provide detailed inspection results, written condition reports for each asset, standard operating procedures, and on-site training for up to 20 agency staff members. All work must adhere to strict industry standards, including NETA MTS, IEEE, NFPA 70E, and ASTM D923, with infrared inspections performed by technicians certified to ASNT Level 1 or higher. This solicitation is open to various small business set-asides, including VOSB, SDVOSB, WOSB, and HUBZone certified firms. Proposals must be submitted electronically via PlanetBids by December 23, 2026, at 3:00 pm. Required documentation includes a detailed project approach, company profile, three references from the last five years, and evidence of cybersecurity compliance via SOC 2 or a completed CAIQ. The agency intends to make a single award to the most capable and cost-effective offeror. Contract administration requires electronic invoicing via ACH, with the agency offering early payment discounts for invoice reductions. Additionally, contractors must be registered with the Department of Industrial Relations and comply with all California Labor Code provisions regarding public works.
Inland Empire Utilities Agency

POSTED

about 4 hours ago

DEADLINE

in about 2 months
NAICS: 238210
New
Purified Water Replenishment San Jacinto Valley Advanced Water Purification Facility
Solicitation # purified-water-replenishment-san-jacinto-valley-advanced-water-purification-facility-2
Axia Electric is soliciting bids from SBE/DBE certified firms for the Eastern Municipal Water District's Purified Water Replenishment San Jacinto Valley Advanced Water Purification Facility Project in California. The scope of work is divided between the San Jacinto Valley Advanced Water Purification Facility and Brine Ponds, specifically requesting subcontractors for low voltage systems, fiber optics, and electrical materials and supplies. Bids must be submitted by 2:00 PM on November 18th, with a final bid date of November 19th at 10:00 AM. Qualified bidders must be registered to perform public work pursuant to Labor Code Section 1725.5 and must adhere to the AGC Master Labor Agreements and the terms of the prime contract. Minimum insurance requirements include 5 million dollars in excess liability, 1 million dollars for auto liability, 1 million dollars for workers compensation and employer liability, and general liability coverage of 1 million dollars per occurrence, 2 million dollars aggregate, and 2 million dollars for completed operations. All submitted bids constitute acceptance of Axia's Standard Long Form Subcontract or Purchase Order. Evaluation factors include timeliness of submission and the inclusion of any lower-tier SBE/DBE participation.
Axia Electric

POSTED

about 4 hours ago

DEADLINE

in 13 days
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management & Training Corporation is soliciting bids for a fixed-price, single lump sum subcontract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project involves the inspection, functional testing, repair, and certification of emergency lighting systems across several facility areas, including the cafeteria, dormitories, education, and recreation buildings. The contractor must ensure full compliance with NFPA 101 (2024 Edition), NFPA 70, and OSHA regulations, and is required to apply durable, uniquely numbered labels to all tested fixtures for future tracking. The estimated contract value ranges between $25,000 and $100,000, with a performance period of 30 business days following the written Notice to Proceed. Bids are due by December 1, 2026, and will be awarded based on overall best value. Mandatory requirements for submission include a physical site visit, a signed bid form, and a detailed cost breakout on company letterhead. For bids equal to or greater than $25,000, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from a surety company with at least an A- rating. This opportunity is set aside for small businesses and various SBA-certified categories. Compliance with the Davis-Bacon Act, Federal Contractor Minimum Wage requirements, and FAR clauses regarding work hours, safety standards, and debarment disclosure is mandatory. Final acceptance is contingent upon a joint substantial completion inspection and the resolution of all punch list items.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in 25 days

AI Contract Overview

Show more

The Santa Clara Valley Transportation Authority is seeking a subcontractor for an Electrical and Lighting Installation project located in San Jose, California. The scope of work focuses on enhancing safety and visibility through the installation of roadway lighting, junction boxes, conduits, and grounding systems. This opportunity falls under NAICS code 238210. Interested parties must submit their responses by the deadline of June 30, 2026. Further details regarding the solicitation can be accessed through the BidAmerica portal.

General Info

Electrical and lighting installation subcontractor for VTA in San Jose, due June 30, 2026.

Documents

This scope was carved out of C26031F.

The full solicitation package (1 document), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

US 101 Express Lanes Phase 5

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Response Deadline

Deadline has passed

Posted

subcontract

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyCalifornia → Santa Clara Valley Transportation Authority
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Installation of roadway lighting, junction boxes, conduits, and grounding systems for safety and visibility.

More opportunities from California → Santa Clara Valley Transportation Authority

Same awarding agency

NAICS: 237130
SLED
Overhead Contact System Rehabilitation Project Phase 4A – Tasman West/East
Solicitation # C26152F
The Overhead Contact System Rehabilitation Project Phase 4A – Tasman West/East, solicitation number C26152F, is issued by the Santa Clara Valley Transportation Authority for work in Santa Clara, California. The project involves the detailed engineering design, procurement, delivery, installation, and testing of an Overhead Contact System (OCS) within the Tasman West Corridor, specifically on Tasman Drive and East Java Drive. Key technical requirements include the installation of new 300 kcmil contact wire, registration insulators, in-span insulators, and surge arresters, extending from traction power substation feeder breakers to the light rail vehicle pantograph. The contractor must provide detailed construction staging schedules to maintain light rail service and perform a pre-construction survey of all OCS and structural components. Bidders must undergo a rigorous pre-qualification process involving a scored questionnaire, where a total score of 57 to 76 is required to pass. Evaluation factors include the firm's claims history and average gross revenue. Qualified contractors must maintain liability insurance of at least $1,000,000 per occurrence and $2,000,000 aggregate, as well of workers' compensation insurance. Because work occurs in an active light rail environment and involves the agency's only LRV wash facility, strict adherence to safety procedures and close operational coordination are mandatory. All submissions must be made electronically via the VTA eProcurement portal by the response deadline of November 13, 2026.
Power and Communication Line and Related Structures Construction

POSTED

about 1 month ago

DEADLINE

in 7 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS