Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

Electrical, Cathodic Protection & Controls

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This subcontract for the Department of Defense at Fort McCoy, Wisconsin, involves the installation of electrical systems and controls for prime contractors. The scope of work includes installing conductors, conduit, panelboards, and Telemetry Control Panels, as well as modifying control equipment at Building 5031. A critical component of the project is the implementation of impressed current cathodic protection in accordance with NACE SP0169 and SP0388 standards, with all work adhering to NEC and NFPA 70 regulations to ensure fully operational electrical and telemetry systems. The opportunity is designated as a HUBZone set-aside under NAICS code 238210. Managed by the W6QM Micc Ft Mccoy agency, the contract was posted on September 1, 2026, with a response deadline of September 17, 2026. Performance will take place in the 54656 zip code area.

General Info

Electrical installation and cathodic protection subcontract for DoD at Fort McCoy, Wisconsin.

Agency

Department Of Defense → W6QM Micc Ft Mccoy (rc)View Agency

NAICS

238210 - Electrical Contractors and Other Wiring Installation ContractorsView NAICS

Place of Performance

WI, 54656

Set-Aside

HZC

Documents

This scope was carved out of W911SA26BA008.

The full solicitation package (7 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

REPAIR SOUTH POST RESERVOIRS

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QM Micc Ft Mccoy (rc)
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of Defense → W6QM Micc Ft Mccoy (rc)
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Installs electrical systems and controls for prime contractors on Army projects at Fort McCoy, WI. Installs conductors, conduit, panelboards, and Telemetry Control Panels (TCP). Implements impressed current cathodic protection (ICCP) per NACE SP0169 and SP0388. Modifies control equipment at Building 5031. Complies with NEC and NFPA 70. Delivers operational electrical and telemetry systems.

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Defense → W6QM Micc Ft Mccoy (rc)

Same awarding agency

NAICS: 237110
New
Federal
REPAIR SOUTH POST RESERVOIRS
Solicitation # W911SA26BA008
The Mission and Installation Contracting Command at Fort McCoy, Wisconsin, is soliciting bids for a firm fixed-price construction project under solicitation W911SA26BA008. The project involves the phased replacement of two 100,000-gallon South Post water reservoirs, including the demolition of existing tanks and foundations, and the connection of a generator to a panel. This requirement is a 100 percent HubZone set-aside under NAICS code 237110, with an estimated project magnitude between 1,000,000 and 5,000,000 dollars. The period of performance is 480 calendar days from the date of the notice to proceed, with work beginning within 10 calendar days of the award. Bids will be evaluated solely on the basis of price and price-related factors. Submission must be completed electronically through the Procurement Integrated Enterprise Environment portal. The contractor is required to provide a quality control plan and adhere to AWWA D100 designs, IEEE standards for electrical grounding, and Davis-Bacon Act wage determinations. Performance and payment bonds are required at 100 percent of the original contract price. All work must comply with the design specifications and drawings dated March 5, 2026, and the contractor must maintain strict adherence to antiterrorism and operational security requirements for access to the installation.
Water and Sewer Line and Related Structures Construction

POSTED

5 days ago

DEADLINE

in 12 days
View Details