Electrical Decommissioning and Reconnection Services

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The contract requires the safe decommissioning and removal of all existing electrical wiring and control systems associated with an old compressor unit, ensuring full compliance with the National Electrical Code and military base safety standards. This includes de-energizing, isolating, and physically disconnecting all components without compromising the integrity of adjacent systems or posing risks to personnel or infrastructure. Following decommissioning, the contractor must install new electrical circuits, control panels, and connections tailored to the new compressor system, ensuring proper load sizing, grounding, protection, and operational reliability in alignment with strict military facility requirements. All work must be performed at the designated location on Beamon Street at Camp Edwards, Massachusetts, with a submission deadline of August 26, 2026. The project falls under NAICS code 238210 for electrical contracting and is structured as a subcontract under the Massachusetts-based Military Division. Performance must adhere to all applicable military base protocols, including security, environmental, and operational constraints. The contractor is expected to demonstrate expertise in hazardous electrical transitions, regulatory compliance, and seamless integration of new systems within a controlled military environment.

General Info

Decommission old electrical systems, install new ones per military code at Camp Edwards by August 26, 2026.

Agency

Massachusetts → MILDV - Military DivisionView Agency

NAICS

238210 - Electrical Contractors and Other Wiring Installation ContractorsView NAICS

Place of Performance

Beamon St Camp Edwards, MA, 02542, USA

Set-Aside

NONE

Documents

This scope was carved out of BD-27-1069-MILDV-30000-132071.

The full solicitation package (20 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

ITB 230354 Air Compressor Replacement at AASF1 (Camp Edwards, MA)

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyMassachusetts → MILDV - Military Division
ContactsNo contacts available
OfficeN/A
Organization / Agency
Massachusetts → MILDV - Military Division
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Safely disconnect and remove electrical wiring and controls from the old compressor system; install and connect new electrical circuits and controls for the new compressor in compliance with NEC and military base standards.

Similar Contracts

Same NAICS industry code

NAICS: 238210
New
Electrical Repair Services
Solicitation # Electrical Services 8-2026
The Management and Training Corporation, acting for the U.S. Department of Labor, is soliciting bids for a fixed-price, single lump sum contract to provide various electrical repair services at the Centennial Job Corps Center in Nampa, Idaho. This SBA set-aside opportunity is open to various small business categories, including SDB, WOSB, HUBZone, and VOSB. Interested bidders must attend a pre-bid meeting on August 21, 2026, and submit their signed proposals and detailed cost breakouts to Sandra Clore by August 31, 2026, at 3:00pm MST. The scope of work includes all electrical services detailed in the Construction Bid Package, requiring the contractor to handle all building permits, incidental work per building codes, and provide a one-year written guarantee of workmanship. The contract is subject to Construction Wage Rate Requirements and requires weekly certified payroll. For bids equal to or greater than 25,000 dollars, a bid bond of 20 percent is required, along with performance and payment bonds from a surety company with at least an A- rating. Payment will be made via progress payments using AIA G702 and G703 forms, contingent upon the submission of a Schedule of Values and the acceptance of work by MTC or the Government. Additionally, the contractor must comply with strict information security and privacy guidelines, including mandatory DOL training and liability for data breaches. Closeout requirements include the delivery of two complete operation and maintenance manuals and all applicable manufacturer warranties.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 7 hours ago

DEADLINE

in 18 days
View Details

More opportunities from Massachusetts → MILDV - Military Division

Same awarding agency

NAICS: 238220
SLED
ITB SPBN262005 Repair HVAC Building 197 (Otis ANGB, MA)
Solicitation # SPBN262005
The Commonwealth of Massachusetts Executive Office of Public Safety & Security Military Division is soliciting bids for the repair and replacement of a compromised primary condensing coil on a Daikin HVAC unit located in Building 197 at Otis Air National Guard Base, Massachusetts. The work requires the full removal of the failed component and installation of a high-performance replacement, which must be an OEM Daikin part or an approved equal meeting or exceeding original manufacturer specifications. The scope encompasses a detailed sequence of tasks including safety isolation and lockout/tagout, refrigerant recovery and containment, mechanical demolition, pressure testing, evacuation, refrigerant charging, and system calibration—all to be performed in strict compliance with federal, state, and local codes, as well as Department of Defense Unified Facilities Criteria, specifically UFC 1-200-01 and UFC 3-410-01. The replacement must pass a high-pressure dry nitrogen test of at least 150 PSI and maintain a vacuum of 500 microns for a minimum of 30 minutes. All work must be completed by a licensed Master HVAC/Pipefitter with EPA Section 608 Universal refrigerant handling certification and OSHA 10-hour safety training for all personnel on site. The project is subject to prevailing wage requirements under the Department of Labor Standards, and certified payroll must be submitted prior to payment. The contractor is responsible for coordinating all security access including background checks, vehicle registration, base passes, and ensuring all personnel are REAL ID compliant due to the site’s location on a secure military installation. Failure to comply with security protocols will not excuse delays in performance. Bids must be submitted electronically via COMMBUYS no later than August 21, 2026 at 10:00 a.m., following specific formatting requirements including a lump sum cost on company letterhead along with mandatory supporting documents: an Authorized Signatory Form, Non-Collusion Form, and Massachusetts Tax Compliance Form. A 5% bid bond is required if the bid exceeds $50,000, with payment and performance bonds mandated at 100% of the project cost for bids over $150,000 and a 50% payment bond for contracts exceeding $25,000. Contractors must also provide liability insurance naming the Commonwealth as additionally insured. The award will go to the lowest responsible and eligible bidder based on past performance and financial soundness, with prompt pay discounts considered in selection.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

8 days ago

DEADLINE

in 8 days
View Details