Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Defense was posted on April 1, 2009. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Electronic Security System Maintenance and Repair

Closed
FA2517-09-T-6037Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 561621
New
Centennial Fire Alarm & CO Detection Upgrade and Maintenance Services
Solicitation # centennial-fire-alarm-co-detection-upgrade-maintenance-services
Management & Training Corporation is soliciting bids for a fixed-price, single lump sum contract to provide fire alarm and carbon monoxide detection upgrade and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The primary objective is to restore the central Simplex 4020 Fire Alarm Control Center Panel and connected systems across nine campus facilities to full operational status. The scope of work includes diagnosing and clearing system faults, upgrading motherboard firmware if necessary, and integrating intelligent multi-criteria CO detectors and sounder bases into the men's and women's dormitories. All work must adhere to NFPA 101 (2024), NFPA 72 (2025), IFC (2024), and local building and fire codes. Bids are due by December 1, 2026, and must be submitted via email with a detailed cost breakout, proof of insurance, and a signed bid form. A physical site visit is mandatory prior to submission. For bids equal to or exceeding $25,000, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from an A-rated surety. This project is subject to the Davis-Bacon Act, requiring compliance with prevailing wage determinations and the submission of weekly certified payroll reports for payment processing. The solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications. Award will be based on overall best value.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 6 hours ago

DEADLINE

in about 1 month
NAICS: 561621
New
SLED
C26950006 - Inland Empire District - Alarm Monitoring Service Contract
Solicitation # C26950006
The California Department of Parks and Recreation is soliciting bids for an alarm monitoring service contract for the Inland Empire District. The selected contractor will provide 24-hour, seven-day-a-week monitoring and maintenance for 31 locations across the Perris, Chino, Mt. San Jacinto, and Silverwood Lake SRA sectors. The scope of work includes the installation, programming, and maintenance of security components such as motion sensors, door contacts, and panic alarms, utilizing Digital Monitoring Products XR150 Network Control Panels with cellular backup and the Virtual Keypad management system. The contract term is for three years, with an anticipated performance period starting February 2, 2027, and ending February 1, 2030. To be eligible, bidders must be a UL Certified Monitoring Center owned and operated by the security installation company and hold a valid California contractor's license as a C-7, C-10, or B contractor. Award selection is based on the Low Price Method, with evaluation incentives available for certified Small Businesses and Disabled Veteran Business Enterprises, as well as preferences under the Target Area Contract Preference Act for bids exceeding 100,000 dollars. Bidders must provide comprehensive insurance coverage, including general liability of 2 million dollars and motor vehicle liability of 1 million dollars. Sealed bids are due by November 6, 2026, at 2:00 PM.
California Department of Parks & Recreation

POSTED

about 16 hours ago

DEADLINE

in 17 days

General Info

NAICS

561621 - Security Systems Services (except Locksmiths)

Place of Performance

Peterson AFB, CO, 80914, USA

Set-Aside

SBA

Documents

5

DD+Fm+254.pdf

PDF

Performance+Plan.docx

DOCX

PWS+Final+3+Mar+09.docx

DOCX

SCA+Wage+Jun+08.docx

DOCX

SF1449.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

4 updates
PhaseClosed
Posted

Presolicitation

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Mar 13, 2009 to Mar 18, 2009. The notice title changed. The notice description changed.

Notice updated

Response deadline time changed from 11:00 PM UTC to 9:00 PM UTC on Mar 18, 2009. The notice description changed. The point of contact changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Type Changed

Presolicitation → Solicitation

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA2517 21 Cons Bldg 350
Contacts2 people available
OfficePETERSON SFB, CO, 80914-1117, USA
Office AddressPETERSON SFB, CO, 80914-1117, USA
Contacts

Full Description

Show more
The purpose of this amendment is to respond to contractor's questions. Question: I saw an item in the "Daily Journal" referencing the above Bid/Quote for Electronic Security System Maintenance/Repair with bids due March 18, 2009 by 4:00 pm. Is there a way to view the specifications and bid documents on line? Response: All specifications and bid documents are posted in the solicitation FA2517-09-T-6037. Question: TEMPEST requirements - Does Tempest requirement apply only to the work completed on-site? According to the NISPOM 11-1-1, it is the GCA Government Contracting Authority) responsibility to identify in writing what TEMP countermeasures are going to be required. The DD254 provided does not clarify this and could impact a proposal depending on who will be funding these requirements. Response: TEMPEST requirements are on-site only. The area is a Sensitive Compartmented Information Facility (SCIF) and does have a TEMPEST Accreditation. The TEMPEST security requirements listed in the NSTISSAM 2-95 and DCID 6-9 is currently being met. IAW RFQ FA2517-09-T-6037 Performance Work Statement, Appendix C, all services must meet the TEMPEST requirements of NSTISSAM 2-95 and DCID 6-9. For example, no remote maintenance, no wireless devices, and RED/BLACK lines will be separated according to NSTISSAM 2/95. All new equipment ordered will be pre-approved by NORAD/NORTHCOM Special Security Officer before purchase is made so that the Government's TEMPEST and security requirements are met. The Government will pay for all new equipment and replacement equipment (except the items bought that are under warranty) to meet TEMPEST requirements. Question: Performance Work Statement - 1.4.3 - How many outside PTZ Camera Domes have swing in parapet mounts? Response: Total of 8 have swing in parapet mounts. Question: Performance Work Statement - 1.4.5.1 - Will up to date hard and soft as-built drawing be provided to accurately up-date any additions to the existing design? Response: No, IAW Performance Work Statement paragraph 1.4.5.1 contractor shall develop and provide two (2) complete up-to-date ESS hard copies and two (2) Auto Computer Aided Drawings (AutoCAD) 2006 or later soft copy as-built drawings to the QAE within four (4) months after contract award. Question: 1.5.2.1 - Is the government asking for the contractor's vendors invoice with no S&H costs added? Response: No, the contractor shall invoice for the costs of all parts used and any related shipping to FOB destination on the cost reimbursable CLIN. Question: Appendix B - Line item - 36 ea. Field equipment power supplies, is this MDI ENCL, or does it include power supplies also. The 36 does not seem to match up with the 20 MDI ENCL's. Response: These are for all the field equipment power supplies to include the MDI enclosures.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS