Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Defense was posted on February 23, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Elevator Maintenance Services at Caven Point Marine Terminal, Jersey City, NJ

Closed
W912DS26QA003Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238290
New
Centennial JCC Panic Hardware Services (Electrical Room Egress Doors)
Solicitation # Panic Hardware (Electrical Room Egress Doors)
Management & Training Corporation is soliciting bids for the installation of commercial-grade panic hardware on electrical room egress doors at the Centennial Job Corps Center in Nampa, Idaho. The project encompasses five specific locations, including the B-Cafeteria, Men's Dorm, Women's Dorm, Recreation, and Vocational areas. The selected contractor must perform site surveys to verify door dimensions and fire ratings, procure Grade I commercial-grade panic bars and matching hardware, and ensure all installations comply with NEC 2023 Article 110.26(C)(3), NFPA 101 Life Safety Code, and ADA standards. Performance verification requires a minimum of 10 consecutive cycle tests to ensure fail-safe operation. This is a fee-for-service subcontracting opportunity set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications. Bidders must submit a lump sum price via a bid sheet, provide three references for similar projects, and complete a supplier onboarding packet including a W-9 and self-certification form. All submissions are due by December 1, 2026, at 3:00pm MST. The contract is subject to various Federal Acquisition Regulations, including prevailing wage rates under the Davis-Bacon Act, Executive Order 14026, and strict information security and privacy breach notification requirements.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 10 hours ago

DEADLINE

in about 1 month
NAICS: 238290
New
SLED
NODC Roll-Up Counter Shutter Replacement
Solicitation # SRC0000042163
Solicitation SRC0000042163 is for a turnkey project to replace the roll-up counter shutter in the canteen of building 610 at the Northwest Ohio Developmental Center in Toledo, Ohio. The scope of work includes the removal and disposal of the existing shutter and the installation of one Wayne Dalton Rolling Counter Door, Model CFS-510. This specific model must be nonrated, clear anodized aluminum with flat slats for face of wall mounting, featuring a right-side hand-crank manual operation and pad-lockable slide bolt locking on both ends. The contract is estimated to be effective from October 19, 2026, through June 30, 2027. Bids will be awarded to the lowest responsive and responsible bidder. Interested parties must submit their quotes via OhioBuys by November 9, 2026, including a completed item grid for parts and labor, a formal quote valid for at least 30 days, and required documentation such as the Standard Affirmation and Disclosure Form and the Contractor Information Form. Bidders may also submit a Contractor Certification Statement Form to claim preferences for Buy American, Buy Ohio, or Veteran Friendly Business Enterprise status. Compliance requirements include adherence to Ohio Prevailing Wage Laws, OSHA safety standards, and strict background and conduct certifications for all personnel working on the grounds of the developmental center.
Developmental Centers, Ddd207000 Northwest Ohio Dc Nwdc

POSTED

about 13 hours ago

DEADLINE

in 20 days
NAICS: 238290
New
SLED
IFB No. 133713 FMS 25 Multiple Roll-up Door Repairs and Preventative Maintenance, Hammer Field Armory
Solicitation # 133713
The California Military Department is soliciting bids under IFB No. 133713 for comprehensive repairs and five-year preventative maintenance of multiple roll-up doors at the Hammer Field Armory (FMS 25) in Fresno, California. The scope of work includes targeted component replacement, safety and control system upgrades, and the full replacement of one door to ensure operational reliability. The selected contractor must possess a D-28 Doors, Gates and Activating Devices license and is allotted 120 calendar days to complete the project. Award will be granted to the lowest responsive responsible bidder, with a 25 percent Small Business participation goal and a 5 percent Disabled Veteran Business Enterprise (DVBE) goal. Prospective bidders were required to attend a mandatory pre-bid job walk on October 26, 2026. All bids must be submitted electronically as a single PDF by November 16, 2026, at 2:00 PM. Required documentation includes a rate sheet and various certifications, such as the Darfur and Iran Contracting Act forms, Payee Data Record, and Non-Collusion Affidavit. The contract mandates compliance with State General Prevailing Wage Rates, the Buy American Act for construction materials, and ADA standards. Payment will be processed electronically in arrears, with invoices submitted no more frequently than monthly and no less than quarterly. Bonding requirements apply if the bid or public works expenditure exceeds $24,999.99, requiring bid, payment, and performance bonds.
California Military Department

POSTED

1 day ago

DEADLINE

in 27 days
NAICS: 238290
New
SLED
Contractor that shall provide comprehensive preventative maintenance, inspections, testing, minor repairs, and reporting services for 9 elevators at the MSDH Central Campus to ensure safe, reliable, and compliant operation in accordance with all applicabl
Solicitation # 1301-27-R-IFBD-00008-V01
The Mississippi State Department of Health is soliciting bids under solicitation number 1301-27-R-IFBD-00008-V01 for a contractor to provide comprehensive preventative maintenance, inspections, testing, minor repairs, and reporting for nine elevators at the MSDH Central Campus in Jackson, Mississippi. The anticipated period of performance is from January 6, 2027, to June 30, 2032, with a maximum cumulative duration of five years including potential one-year renewals. The scope of work includes monthly maintenance per manufacturer recommendations, annual safety inspections and full load testing, and 24/7 emergency callback services with a two-hour on-site response time. The base contract covers labor and parts for minor repairs up to 250 dollars per incident. All services must comply with ASME A17.1 Safety Code, ADA requirements, OSHA safety regulations, and State of Mississippi standards. The contract will be awarded to the lowest responsible and responsive bidder. To be deemed responsible, vendors must have at least five years of experience in similar services, be registered with the Mississippi Secretary of State, and hold a valid Mississippi Elevator Contractor License. Required insurance includes workers compensation and general or professional liability insurance with minimum limits of 1,000,000 dollars per occurrence, naming MSDH as an additional insured. Bids must be submitted electronically via the OpenGov Procurement portal by 2:00 pm CST on November 20, 2026. Payments will be made via the state's electronic remittance vehicle, with undisputed amounts typically paid within 45 calendar days of invoice receipt.
MS DEPT of HEALTH

POSTED

1 day ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

This contract involves comprehensive elevator maintenance services at the Caven Point Marine Terminal in Jersey City, NJ, specifically for a Schindler 330A Hydraulic Elevator. The contractor is responsible for performing monthly, semi-annual, and annual inspections and maintenance tasks following the manufacturer’s guidelines and regulatory requirements. Maintenance duties include detailed upkeep of hydraulic systems, controllers, door systems, hoistways, buffers, emergency systems, and safety features, as well as cleaning, lubrication, and verification of operational compliance. The scope includes providing unlimited callback service during regular government working hours at no extra charge, with a 24-hour response requirement for emergency calls, except for vandalism-related issues. The contractor must maintain detailed logs and schedules, including a preventive maintenance schedule, work log, and trouble log, all accessible for government review. Inspection fees by regulatory authorities and any necessary re-inspections due to deficiencies are to be covered by the contractor. When equipment is out of service, appropriate signage or barriers must be installed. The contract is a firm fixed price agreement set aside for small businesses under the SBA program, with quotes to be submitted electronically by a specified deadline. The selection will prioritize the lowest priced, compliant offer, and requires contractors to have current certifications and licenses. The contract ensures thorough supervision, labor, equipment, and materials will be provided to maintain elevator safety, reliability, and regulatory compliance.

General Info

Comprehensive Schindler elevator maintenance with inspections, emergency service, logs, and regulatory compliance.

NAICS

238290 - Other Building Equipment Contractors

Place of Performance

Jersey City, NJ, 07305, USA

Set-Aside

SBA

Documents

2

Solicitation W912DS26QA003 Elevator Service Contract CPMT

PDF, High priority: read this first43 pages · rfp
High

WD1988-0590 Rev61 Wage Determination for NJ and NY

PDF, High priority: read this first2 pages · wage-determination
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

1 update
PhaseClosed
Posted

Solicitation

Notice updated

Notice details unchanged. Attachments may have changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W2SD Endist New York
Contacts2 people available
OfficeNEW YORK, NY, 10278-0004, USA
Office AddressNEW YORK, NY, 10278-0004, USA
Contacts
Orlando Nieves
Matthew Lubiak

Full Description

Show more

Elevator Maintenance Services at the Caven Point Marine Terminal, Jersey City, NJ. Monthly, Semi-Annual, and Annual inspections and maintenance tasks as specified in the Statement of Work.


General Requirements


  1. Scheduling of Preventive Maintenance, Service and Repairs.

Normal Work: The Contractor shall perform all normal work under this agreement, including unlimited call-back service, will be performed during the hours of 7:00 a.m. to 3:30 p.m. on all regular working days observed by the Federal Government (hereinafter called Regular Working Hours). If overtime work is required, the Government will pay only at the Contractor's regular billing rate as accepted by the Government. Emergency circumstances are understood to be those which pose imminent possibility of equipment damage or worker injury as judged by the Contractors employees.


  1. Emergency Call Back Service

Callback service during Regular Working Hours: The Contractor shall, without additional charge to the government, provide emergency minor callback service for any reasons, excluding vandalism, during the regular working hours. The Contractor shall respond to a callback within a maximum of twenty-four (24) hours from the time the request for service is made by the Government’s authorized personnel.


  1. Time Tickets

Contractor shall provide time tickets signed by the Government’s representative at the completion of each regular examination or repair which must include date, equipment, and identification, time of arrival, time of departure, nature of visit, action taken and name of qualified serviceman. A copy of the time ticket shall be left with the Government’s representative at the site. The Contractor agrees that this time ticket is provided for the sole convenience of the Government. The Government’s representative does not undertake to approve or to certify as to the correctness, adequacy, or performance of any work. The time ticket only provides proof of Contractor’s physical presence at the site at the time the Government’s representative signs the time ticket.


  1. Maintenance schedule and work log


The Contractor shall post a preventive maintenance schedule and a work log in the elevator machine room located on the 1st floor of the building. The log shall include all entries for routine maintenance and repairs, including supervisor’s surveys. Entries shall include but not exclusively date work is completed, mechanic’s or supervisor’s name, description of work completed, and the approximate time required for the work. The log and maintenance schedule shall be maintained and shall be presented quarterly to the Government for review. The Government may  inspect and copy log and maintenance schedule at any time.



  1. Trouble Log

A trouble log shall be maintained by the Contractor in the elevator machine room of the building. The Contractor shall record in the log as a minimum, the date of each callback, the time reported, the time left, the reported trouble, the problem found and the corrective action taken. In addition, the Contractor shall report this information semi-annually in writing and in a mutually agreed upon format and tender same to the Government's representative so as to also review the operational status of the Elevator trouble call control log.


  1. Inspection fees

Inspection fees charged by Regulatory Authorities shall be paid by the Contractor. Fees for re-inspection due to failure to eliminate deficiencies covered by this maintenance agreement will be paid by the Contractor. The Elevator is not regulated by the State of New Jersey, or the City of Jersey City. The Annual Inspection will need to be done by a Bureau Veritas Inspector to certify their National Elevator Inspection Service.



  1. Signs and/or Barriers

When elevator equipment is taken out of service for whatever reason by the Contractor, signs and/or barriers shall be placed at all floor entrances to the elevator indicating that the elevator is out of service.


Equipment Data


Manufacturer: Schindler


Model: 330A Hydraulic Elevator


Drive Mechanism: Hydraulic Single Jack Holeless Power: Three Phase, 35kVA


Pump and Motor: Type E: Submersible



Technical Tasks


The contractor will be responsible to provide all supervision, labor, equipment and materials to accomplish the following maintenance tasks in accordance with the manufacturer’s recommendations and all applicable regulations.


Annual Maintenance


  1. Annual Bureau Veritas, National Elevator Inspection Service.
  2. Maintain and clean pressure tanks
  3. Test pressure/relief valve


Semi-annual Maintenance


  1. Maintain controllers, wiring, wiring diagrams, code data plate, controller operation, components, motor starter
    1. Maintain and clean components of controller
    2. Confirm up to date wiring diagrams are available
    3. Ensure no temporary devices or jumpers in place
    4. Maintain code data plate and periodic test tag
    5. Test and if necessary replace control battery
  2. Confirm signs and data plates
    1. Replace any missing or damaged signs or data plates
  3. Lube guide rails
    1. Maintain, lubricate and clean guide rails
    2. Maintain/empty excess lubrication container in pit
    3. Ensure rust preventative compounds only used if specified by manufacturer
  4. Maintain oil buffers
    1. Maintain oil level in buffer as specified by manufacturer
    2. Maintain plunger, clean, ensure not coated or painted with substance that will interfere with operation
    3. No buffer oil in pit, hoistway or top of car
  5. Clean hoistway and pit
    1. Ensure hoistway and pits free of rubbish/debris, water, oil and that they are not used for storage
    2. Landing blocks and pipes may be kept in the pit as long as they do not interfere with the operation of elevator
    3. If provided, verify pit access doors can close and lock
  6. Maintain overall machine room space/ controller room space
    1. Maintain machine/ control rooms/ spaces so they are free from dirt, rubbish, oil water, grease, materials not necessary for maintenance and flammable liquids
    2. Verify access doors are closed and locked
  7. Clean car top
    1. Maintain top of car – free of oil, water, dirt and rubbish
    2. No tools, spare parts or lubricants shall be stored on car top
  8. Maintain door system
    1. Maintain landing and car-door or gate mechanical and electrical components to ensure safe and proper operation
      1. Maintain hoistway door interlocks or mechanical locks and electrical contacts, car door electrical contacts or car door interlocks, door reopening devices, vision panels and grilles, hoistway door unlocking devices and escutcheons, door hangers, tracks, rollers, upthrusts and safety retainers, astragals and resilient members, door space guards and sight guards, sills and bottom guides, fastenings, condition and engagement, clutches engaging vanes, retiring , cams and engaging rollers, interconnecting means, door closer, door restrictors, closing kinetic energy and closing force, etc.
  9. Maintain hoistway access switches and examine car top equipment
    1. Maintain the operation of the hoistway access switch
    2. Inspect cat top equipment
  10. Maintain car emergency system and examine cab interior components and fixtures
    1. Maintain and ensure that the car emergency signals are operating properly
    2. Maintain and ensure that lighting, communication and ventilation are operating properly
  11. Maintain stopping accuracy and ride unit
  12. Maintain liquid level in pressure tanks
  13. Maintain and clean water hydraulic plunger
  14. Maintain tank oil level
  15. Maintain gland packings, seals, collection of oil leakage
    1. Maintain packing and seals to prevent excessive fluid loss
    2. If any packing or seal is replaced a relief valve test must be performed for 15 seconds
    3. Oil leakage must not exceed 5 gallons from the cylinder head
    4. Ensure the collection container is covered and is not overflowing
  16. Maintain flexible hose and fittings
    1. Maintain flexible hoses and fittings, observe for evidence of leaking, damage or bulging
    2. Hoses shall be replaced every 6 years post installation
  17. Record oil usage
    1. Hydraulic systems with unexposed cylinders or piping, where visual examination is not possible, main a record of usage.
    2. Record all hydraulic fluid added and emptied from leakage containers and pans. If fluid loss cannot be accounted for a relief valve and pressure test shall be performed.
  18. Maintain safety bulkhead
    1. Single bottom jacks, installed prior to 1971, require car safeties or a plunger gripper
  19. Maintain relief value setting and examine pump unit operation and components
    1. Maintain relief valve – ensure the relief valve seal is intact
    2. If the seal is not intact, test the adjustment and reseal


Monthly Maintenance


  1. Inspect Elevator is in proper working order
  2. Ensure Elevator is in compliance of all applicable regulations.


INSTRUCTIONS TO QUOTERS: Quotes shall be submitted by email, as a PDF document to matthew.e.lubiak@usace.army. mil and orlando.nieves@usace.army.mil. Quotes must be signed and dated, and completed with prices for all items. Quoters are reminded to ensure that online Representations and Certifications in SAM are up to date, or may provide completed Representations and certifications with their quote. Quotes must conform to the solicitation requirements to be eligible for award. The evaluated price will be the total price of all items (Total Base + Options). The lowest price quote that conforms to the solicitation requirements, including any required certifications, licenses, etc. will be considered the best value to the Government and will be selected for award of a firm fixed price contract.

More opportunities from Department Of Defense → W2SD Endist New York

Same awarding agency

NAICS: 237990
New
Federal
Two Phase Design and Construction of the Port Monmouth Phase II, Contract 1 Mitigation Project
Solicitation # W912DS26RA032
Solicitation W912DS26RA032 is a competitive two-phase design-build procurement issued by the US Army Corps of Engineers, New York District, for the Port Monmouth Phase II Contract 1 Mitigation project in Middletown, New Jersey. With an estimated project magnitude between $15 million and $30 million, the scope involves the design and construction of wetland and upland restoration at the Pews Creek and Compton Creek mitigation sites. The project aims to reduce storm damages from coastal erosion and flooding in Raritan Bay, specifically focusing on restoring approximately 24.83 acres of wetlands and channels and 8.76 acres of uplands. The State of New Jersey Department of Environmental Protection serves as the non-Federal sponsor. The procurement follows a best-value tradeoff process in accordance with FAR 36.3, where non-price evaluation factors are approximately equal in importance to price. Phase One focuses on qualifying offerors based on specialized experience and past performance to shortlist up to five firms for Phase Two. Final award will be a firm fixed-price contract. Key requirements include strict adherence to New Jersey environmental standards, the provision of performance and payment bonds, and compliance with the Davis-Bacon Act. Following multiple amendments, the final response deadline for proposals was extended to October 21, 2026.
Other Heavy and Civil Engineering Construction

POSTED

about 14 hours ago

DEADLINE

in about 16 hours
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS