Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, July 22 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Government of Canada was posted on January 24, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Emergency Backup Generator Replacement Canadian Coast Guard Base Parry Sound, ON

Closed
30003862Canada

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Government of Canada → Fisheries and Oceans Canada

NAICS

N/A

Place of Performance

*Ontario (except NCR), CAN

Set-Aside

NONE

Documents

(1)

30003862_-_rfq_en.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → Fisheries and Oceans Canada
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → Fisheries and Oceans Canada
Office AddressN/A
Contacts
Dorgbetor FortunaPoint of Contact

Full Description

Show more
NOTICE OF PROPOSED PROCUREMENT (NPP)This requirement is for Fisheries and Oceans Canada, Canadian Coast GuardObjective:DFO wishes to engage a Contractor to remove the existing backup generator and install the new emergency backup generator which encompasses mechanical, electrical and civil/structural coordination.Scope of Work:At the CCG Parry Sound Base we have a requirement to replace the existing 250 kW diesel backup generator that was installed in the mid 1980’s which is beyond its service life with a new generator (diesel) appropriately sized to provide backup power to the base.Contractor must remove and replace the existing generator with a new generator (purchased and on-site). The existing generator is comprised of a diesel fueled generator while the new generator is to a natural gas powered 200 kW Cummins generator which has been purchased and is on-site at the Parry Sound CCG Base.The project has been generalized to the following components:The Contractor must disconnect and remove existing generator (to be left on-site);Structural modification of existing generator pad;Mechanical exhaust and piping work;Electrical connections; andAll temporary work to support above requirementsSecurity Requirement:There is no security associated with this requirement.Period of Contract:The period of contract shall be 6 weeks from date of award.Contract Authority:Name: Fortuna Sophia DorgbetorPhone Number: 450-521-9004Email Address: DFOtenders-soumissionsMPO@dfo-mpo.gc.ca & C.c: Fortuna.Dorgbetor@dfo-mpo.gc.caInquiries:Inquiries regarding this RFP requirement must be submitted to the Contracting Authority named above. BIDDERS ARE ADVISED THAT “BUYANDSELL.GC.CA” IS NOT RESPONSIBLE FOR THE DISTRIBUTION OF SOLICITATION DOCUMENTS. The Crown retains the right to negotiate with any supplier on any procurement. Documents may be submitted in either official language.