This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on September 20, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Environmental Temperature Monitoring System

Closed
FA3016-16-N-0182Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334512
New
DIBBS
THERMOSTAT, FLOW CONTRO
Solicitation # SPE4A5-27-T-1389
Solicitation SPE4A5-27-T-1389 is a federal procurement issued by the DLA Weapons Support ASC Supplier Oper OEM Division for the acquisition of 63 flow control thermostats, identified by NSN 6685-12-360-1961. The requirement specifies several compatible part numbers from manufacturers including IML Motori SRL, Deutz AG, and Augusta Engine Parts, Inc. The items are designated as critical application items and must be delivered FOB Origin to DLA Distribution Cherry Point in North Carolina. The need ship date is April 13, 2027, with an original required delivery date of April 25, 2027. The contract mandates strict quality and packaging standards, requiring compliance with MIL-STD-2073-1E for packaging and MIL-STD-129 for marking, specifically utilizing special marking code 05 for delicate instruments. Inspection and acceptance will occur at the destination, with sampling conducted according to MIL-STD-1916 or ASQ H1331. Administrative requirements include electronic invoicing via the Wide Area WorkFlow system and adherence to the Hazard Communication Standard for any hazardous materials. The procurement is governed by the DLA Master Solicitation for Automated Simplified Acquisitions Revision 105 and prohibits the use of additive manufacturing unless specifically authorized. Evaluation may include a HUBZone price preference, and the buy is identified as a candidate for automated award.
DLA WEAPONS SUPPORT ASC SUPPLIER OPER OEM DIVISION

POSTED

2 days ago

DEADLINE

in 6 days

General Info

Contract Value

$24,362.8

NAICS

334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use

Place of Performance

JBSA-Lackland Blood Bank, JBSA-Lackland, TX, USA

Set-Aside

SBA

Award Issued Date

Documents

3

Bid_Specifications.pdf

PDF

Essential_Characteristics_for_Temperature_Monitoring_Device.pdf

PDF

RFQ_-_Blood_Donor_Center.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

5 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Sep 8, 2016 to Sep 22, 2016. The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA3016 502 Cons Cl
Contacts1 person available
OfficeJBSA LACKLAND, TX, 78236-5286, USA
Office AddressJBSA LACKLAND, TX, 78236-5286, USA
Contacts

Full Description

Show more
This system will be self-contained and not connected to a network with internet access. The device that receives all of the data will be hard-wired to a stand-alone computer. Anything requiring a server will not meet the government's need. The computer will run the software relating to the temperature data; therefore, it is a requirement that the software run without internet access. This system will also be connected to an analog phone line that notifies users of excursions; therefore, it is a requirement that the software be able to place phone calls over an analog phone line. Although the phone line in place now is analog, it is possible that in the future the government may switch to a digital phone line. For that reason, the system must also have the capability to place phone calls over a digital/VoIP phone line. The communication between the temperature probes and the device(s) that receive(s) this information must be self-contained and not require connection to the government wifi network. For example, a wired network, or a secured 418MHz or 900 MHz wireless network would be sufficient. 19 temperature probes are currently required, however the system must be able to be expanded to at least 50 probes if necessary. The new close date for this solicitation is 22 September 2016 at 9 a.m. local San Antonio, TX time.

More opportunities from Department Of Defense → FA3016 502 Cons Cl

Same awarding agency

NAICS: 238210
New
Federal
DCF3 PROJECTION SYSTEM
Solicitation # A070977
The Department of Defense, specifically the 502 Cons Cl under the Office of the Air Force, is issuing a sources-sought Request for Information (RFI) for the DCF3 Projection System, solicitation number A070977. The objective is to identify capable providers for the installation of standalone audio-visual (AV) classroom equipment in sixteen classrooms at the BMT DCF3 (Building 9270) located at JBSA-Lackland, Texas. The scope of work includes providing all personnel, equipment, and materials to install laser projectors, zoom lenses, lecterns, scaling switchers, and associated cabling. The system must operate as a standalone solution and is strictly prohibited from interfacing with the Air Force network. Key deliverables include the integration of Apple Government-Furnished Equipment, the provision of technical documentation, and the delivery of user training for staff. Technical requirements specify that projectors and extension columns must be Trade Agreement Act (TAA) compliant, and touch panels must be FCC Class A certified. The contractor is responsible for ensuring high video resolution and sound quality, with final acceptance based on a post-installation walkthrough and inspection at the project site. Security requirements are stringent, requiring criminal history checks and background investigations for all personnel accessing the base, as well as strict adherence to Force Protection Condition procedures and a total prohibition of weapons on site. This RFI is strictly voluntary and is not a formal solicitation for quotes; interested parties must submit their capabilities and open-market pricing via email to Tommie Low by October 27, 2026, at 10 a.m. CST.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in 7 days
View Details
NAICS: 238220
New
Federal
Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement
Solicitation # A070764SS
The 502d Contracting Squadron is conducting market research via a Sources Sought Synopsis to identify capable industry sources for the turnkey removal and replacement of 48 ceiling-suspended Dedicated Outside Air System Water-Source Heat Pumps at the JBSA Ft Sam Houston San Antonio Military Medical Center Dormitory Annex, specifically in buildings B3631 and B3635. The project is projected as a Firm-Fixed Priced Purchase Order under NAICS code 238220. The contractor must provide all personnel, equipment, and supervision to install units that meet strict technical specifications, including a 1.25-ton capacity, horizontal ceiling-plenum configuration, and the use of low-GWP refrigerants such as R-454B or R-32, as R-410A is strictly prohibited. A critical requirement is that replacement units must fit through existing access openings measuring approximately 3 feet 11.5 inches by 2 feet to avoid structural demolition. The scope of work includes the integration of the units into the central Building Automation System via BACnet IP/MSTP and the use of AHR/ISO 13256-1 certified water-to-refrigerant coaxial heat exchangers. Performance must be completed within 275 days of award. Interested respondents must provide company identification, SAM.gov certifications, and confirmation that technicians hold EPA Section 608 Universal Certifications. Small business prime contractors must also verify they can cover at least 51 percent of the contract cost with their own personnel. Responses are due by October 26, 2026, and must be submitted in PDF format with a maximum length of ten pages, excluding equipment cut sheets.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

6 days ago

DEADLINE

in 6 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS