Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity was posted on June 2, 2017. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Exactech Equinoxe System-Shoulder

Closed
W91YTZ-17-T-7135Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

Solicitation W91YTZ-17-T-7135 concerns the procurement of the Exactech Equinoxe Shoulder System for use at Fort Gordon, Georgia. This specialized system is designed for the reconstruction of proximal humerus pathology and is distinguished by its modularity, which allows for the intra-operative or post-operative conversion between hemi arthroplasty, total shoulder arthroplasty, and reverse arthroplasty. Key technical features include a glenoid baseplate with a built-in offset to prevent humeral liner impingement and a humeral stem capable of anatomic tuberosity reconstruction, even in cases of chronic mal-union or non-union. The specific requirements include various expanded glenospheres with lateral offsets and a range of glenoid plates, including standard, superior augment, posterior augment, and expanded cage options. Vendors proposing substitute items must provide detailed brand names, catalog numbers, and equivalence documentation for evaluation; failure to do so will result in disqualification. The contract will be awarded to the lowest evaluated price proposal that meets or exceeds all non-cost acceptability standards.

General Info

Procurement of Exactech Equinoxe Shoulder Systems for proximal humerus reconstruction at Fort Gordon.

Agency

N/A

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Dwight David Eisenhower Army Medical Center 300 East Hospital Road Fort Gordon, Georgia 30905 United States Fort Gordon, Georgi, FORT GORDON, GA, 30905, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts2 people available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A

Full Description

Show more
Description: This system is unique its multiple options for reconstruction of proximal humerus pathology . The system offers a wide range of glenoid solutions, including cages. The glenoid baseplate design has a built-in offset which distally shifts the glenosphere to a position that prevents humeral liner impingement on the inferior glenoid Unlike any other system, it modularity of implants allows for easy intra-operative or even long-term post-operative exchange of implants from a hemi arthroplasty to a total shoulder arthroplasty or a reverse arthroplasty. The arthroplasty systems allow the most options for glenoid baseplate fixation on the market and their humeral stem is unique in its ability to allow anatomic reconstruction of the tuberosities even in the setting of a chronic mal-union or non-union. Optimal results are best obtained when this implant is used for shoulder arthroplasty compared to other available system from other vendors. Exactech System 320-02-38 38mm Expanded Glenosphere +4mm Lateral Offset 320-02-42 42mm Expanded Glenosphere +4mm Lateral Offset 320-15-01 Standard Glenoid Plate 320-15-02 Superior Augment Glenoid Plate, 10 degrees 320-15-03 Superior Augment Glenoid Plate, 8 degrees left 320-15-04 Posterior Augment Glenoid Plate, Eight Degree, Right 320-15-06 Expanded Cage Glenoid Plate +10 mm 320-15-07 Superior/Posterior Augment Reverse Glenoid Plate, Left 320-15-08 Superior/Posterior Augment Reverse Glenoid Plate, Right 1 each SUBSTITUTE ITEMS: If you plan to provide other than the brand name cited in the purchase description, provide in your response the brand name and the catalog or part number you intend to furnish and the characteristics of the substitute item that are equivalent to the brand name. Also provide all documents which clearly describe the item(s) so that it/they can be evaluated by the end user. Failure to submit the requested substitute item information before the closing date listed above will eliminate the vendor from all further consideration. Items otherwise equal may not satisfy the requirement due to differences in material composition, size, environmental application, etc. If an item is furnished which does not meet the requirement the item will be returned at the vendor's expense for a full refund. Award will be made on the basis of the lowest evaluated price of proposals meeting or exceeding the acceptability standards for non-cost factors

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS