Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on August 19, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Expanision of Motorola Mach Fire Alerting System

Closed
F1D3226121AW04FireAlertFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency is soliciting proposals under RFP-VC-26-010 for transformer oil testing services to enhance the reliability, safety, and maintainability of its transformers. The scope of work is divided into three primary areas: conducting visual and infrared thermographic inspections to identify thermal anomalies, installing standardized external oil sampling devices for safer collection, and performing detailed oil testing analysis. Additionally, the contractor is required to evaluate nitrogen blanket systems to ensure positive pressure is maintained, provide on-site training for agency staff on inspection tools, and develop comprehensive standard operating procedures. All work must adhere to strict technical and safety standards, including ASNT Level 1 certification for thermography, ASTM D923 and D924 for oil sampling, and NFPA 70E safety protocols. The agency intends to make a single award to the most capable and cost-effective offeror, evaluating candidates based on their staffing plan, personnel availability, fee structure, and a proven track record of performing similar projects for utilities or industrial facilities. Proposals must be submitted electronically via PlanetBids by December 23, 2026, and must include a detailed project approach, company profile, and required certifications such as non-collusion and workers compensation. The resulting contract will feature fixed pricing for an initial term with potential one-year extensions. Awardees must comply with California Labor Code prevailing wage requirements and maintain strict confidentiality regarding all agency reports and data.
Inland Empire Utilities Agency

POSTED

about 7 hours ago

DEADLINE

in 2 months
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management and Training Corporation is soliciting bids for a fixed-price, single lump sum contract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project involves a qualified electrical contractor inspecting, testing, repairing, and certifying emergency lighting systems across the facility, including the cafeteria, recreation building, and dormitories. Key tasks include performing functional tests by simulating utility outages, replacing failed ballasts with LED-compatible versions, and applying durable labels to fixtures for future tracking. The contractor must ensure full compliance with NFPA 101 (2024 Edition) and NFPA 70 standards, integrate recurring maintenance into the center's Computerized Maintenance Management System, and provide certificates of disposal for hazardous materials. The estimated contract value ranges from $25,000 to $100,000, with a performance period of 30 business days following the Notice to Proceed. Bids are due by December 1, 2026, and must include a detailed cost breakout and a mandatory physical site visit. For bids of $25,000 or more, a bid bond of 20% is required, and the awarded contractor must provide performance and payment bonds from a surety with at least an A- rating. This solicitation is set aside for small businesses and various SBA-certified categories. Award decisions will be based on overall best value. Compliance requirements include adherence to the Davis-Bacon Act, Federal Contractor Minimum Wage, and FAR regulations regarding work hours, safety standards, and the Buy American Act.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 7 hours ago

DEADLINE

in about 1 month

General Info

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Place of Performance

Joint Base Andrews, MD, 20762, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA2860 316 Cons Pk
Contacts1 person available
OfficeJB ANDREWS, MD, 20762-7001, USA
Office AddressJB ANDREWS, MD, 20762-7001, USA
Contacts

Full Description

Show more
This is a sources sought synopsis in support of a market survey being conducted by the 11th Contracting Squadron, Joint Base Andrews, MD 20762 in accordance with Federal Acquisition Regulation Part 10, Market Research, to determine interest and capabilities of potential sources for expanding upon the Mach Alert Fire Station Alerting (FSA) System currently being implemented at Joint Base Andrews (JBA). The extension will be for adding alerting capabilities to the Amubulatory Care Center (ACC) on JBA. The system currently implemented at other locations was designed with the ability to expand as necessary to assist in first responder alerting across the base. The proposed expansion will leverage both LMR and IP-based connectivity to ensure that communications will always be established between the two JBA Fire Stations and the ACC. This synopsis is for informational and planning purposes only and does not constitute a solicitation, a synopsis of a solicitation, a commitment on the part of the Government to later publish a solicitation, or ultimately award a contract. The Government will not reimburse the costs of preparing or submitting a response to this synopsis. The intent of this notice is to identify potential offerors to provide for the above listed items. Interested sources capable of providing this requirement must respond by e-mail to justin.g.parrish.mil@mail.mil, referencing "Fire Alert System", no later than 29 August 2016 at 12:00PM EST. Interested sources shall indicate whether they are capable of providing for the subject requirement, and furthermore indicate their size and status (i.e., small business, 8(a), HUBZone, WOSB, SDVOSB, etc.). No other information is required at this time. Based upon the responses received, the Government will determine the set-aside method for the procurement. An award will not be made on offers received in response to this notice. This sources sought synopsis is not a Request for Quote (RFQ); it is a market research tool being utilized to determine the availability of sources.

More opportunities from Department Of Defense → FA2860 316 Cons Pk

Same awarding agency

NAICS: 811310
New
Federal
Overhead Hoist Maintenance Joint Base Andrews
Solicitation # SSNFA2860
The Department of Defense, through the 316 Cons Pk office, is issuing a sources sought notice for a small business set-aside contract to provide comprehensive maintenance, testing, and certification for overhead hoists and associated equipment at Joint Base Andrews and Davidsonville, Maryland. The scope of work requires the contractor to furnish all labor, transportation, equipment, and supervision for annual certified inspections and both routine and emergency service call repairs. All work must be performed by qualified technicians with formal training and must adhere to OSHA, ASME, ANSI, and DAFMAN 91-203 standards, as well as original equipment manufacturer specifications. Key deliverables include the submission of a Quality Control Plan within 15 calendar days of award and the provision of certification inspection certificates to the Contracting Officer's Representative within five business days of completion. For payment, the contractor must provide service tickets annotated by the COR and follow specific reimbursement protocols for parts, requiring a single invoice for items under 3,000 dollars and three competitive quotes for items exceeding that amount. Access to Joint Base Andrews requires the submission of detailed personnel and vehicle information, and strict adherence to installation security policies regarding prohibited weapons and controlled substances is mandatory.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

6 days ago

DEADLINE

in 10 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS