Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from California was posted on October 9, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Fire Alarm System

Closed
BID NO. 02-24/25.R1State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 922160
SLED
2026 Volunteer Fire Capacity Grant
Solicitation # 2139681
The New York State Department of Environmental Conservation is administering the 2026 Volunteer Fire Capacity Grant Program, funded by a federal appropriation of 857,629 dollars. This program provides matching grants to eligible rural fire departments for the purchase of wildland firefighting suppression supplies. To be eligible, departments must be comprised of at least 80 percent volunteer personnel and serve a rural area, defined as a town or village with a population of 10,000 or less based on the 2020 Census. Selected departments can receive a maximum award of 3,500 dollars, which must be matched 50/50 by the recipient. Grant funds must be used for items directly related to wildland firefighting that benefit the local rural community, with a restriction that no individual item exceeds 9,999 dollars. Selection is based on the department's funding history over the previous five years, whether it is a newly formed establishment, and the presence of a Native American community within its jurisdiction. The program operates under federal guidelines from the US Forest Service and the Cooperative Forestry Assistance Act of 1978. Applications are accepted through December 30, 2026. This solicitation does not have specific goals for Service-Disabled Veteran-Owned, Minority, Women, or Disadvantaged Business Enterprises. All inquiries and applications are managed by the Volunteer Fire Capacity Grant Coordinator within the Division of Forest Protection.
NYS Department of Environmental Conservation

POSTED

7 days ago

DEADLINE

in 2 months

AI Contract Overview

Show more

The Pasadena Unified School District (PUSD) is seeking bids for Fire Alarm Testing and Maintenance Services across its 28 schools and associated programs within Pasadena, Altadena, Sierra Madre, and parts of Los Angeles County. The contract will be effective for up to five years, including four optional one-year renewals, with a total project value estimated between $500,000 and $2,000,000. Qualified contractors with experience in NOTIFIER-HONEYWELL systems and holding a California C-16 Fire Protection Contractor License are required to submit proposals. The scope includes performing routine and annual fire alarm testing in compliance with NFPA 72 standards and the 2019 California Fire Code, primarily after hours or on weekends, with detailed testing methodologies and estimated timelines to be included in proposals. Contractors must also provide certification documentation upon completion and submit a schedule for testing at 34 specified sites within 30 days of contract award. Additionally, the selected contractor will handle on-call maintenance requests, including repairs and updates to fire alarm control panels, sensors, power supplies, and related equipment. They will be responsible for initial programming of alarm panels to ensure proper communication with central stations, with the district covering costs for one programming visit per site. The bid deadline is November 5, 2024, and interested parties can access further details through the provided contact and online portal. The contract emphasizes compliance with local codes, proper certification, and experience with specific fire alarm systems to ensure safety and regulatory adherence across all district sites.

General Info

Agency

California → Pasadena Unified School District

Place of Performance

CA, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyCalifornia → Pasadena Unified School District
Contacts1 person available
OfficeN/A
Organization / Agency
California → Pasadena Unified School District
Office AddressN/A

Full Description

Show more
A contract awarded through this Bid (“Contract”) will be effective for a period not to exceed five years, which includes four, one- year options to renew.Pasadena Unified School District (PUSD) enrollment of more than fourteen thousand (14,000) students in grades TK-12th grade in a 76-square mile area that includes Altadena, Pasadena, Sierra Madre, and unincorporated areas of Los Angeles County. PUSD currently operates twenty-eight (28) schools and programs. Thirteen (13) elementary schools (grades K-5), one (1) K-8, three (3) middle schools (grade 6-8), two (2) 6-12th grade schools, two (2) high schools (grades 9-12), one (1) continuation high school, one (1) alternative education program, five (5) children centers. The Pasadena Unified School District (PUSD) is inviting Bids from qualified individuals, firms, partnerships, corporations, associations, or professional organizations for Proposals and quotes to provide Fire Alarm Testing and Maintenance Services to Pasadena Unified Schools within cities of Pasadena, Altadena and Sierra Madre.a) Testing and Maintenance: Perform routine and annual fire alarm testing for all school sites referenced below per LBFD NFPA72 Requirements. To ensure jurisdictional compliance with inspection, testing and maintenance laws to meet the needs of local code officials. Annual testing and routine maintenance costs shall be included in the proposal. The annual required testing of the fire alarm panels, and related equipment shall be in accordance with NFPA 72 test methods and the 2019 California Fire Code. Contractors must include in their proposals a brief description of their testing methodology and the estimated time frame to perform the testing. All alarm testing shall be performed after business hours or on weekends. Contractors shall include the appropriate labor rates in their proposals.The proposed cost for service shall be the basis for the fixed cost on the individual bid items for Bid No. 02-24/25.R1 Fire Alarm System (Current/Future) Districtwide (see Bid Line Items - Mandatory Bid Forms - Bid Form Document). b) NFPA72 Certification: Shall be emailed upon completion to Pasadena Unified School District Maintenance & Operations Department, attention Director, Facilities, M&O, and Transportation. Preferably, all site inspections and testing will be performed after school hours and Saturdays while following site noise ordinance set by the school district. c) The selected Contractor shall provide to the Electrical Department M&O Designee within 30 days after contract execution with a schedule for the annual testing and maintenance services for multiple school and administration sites listed in the specifications. The Schedule shall include the estimated dates for performing testing at each site, Thirty Four (34) sites, for the duration of the contract see exhibit A. d) In accordance with the California Labor Code, only contractors with experience with NOTIFIER - HONEYWELL systems will be considered. A California C-16 Fire Protection Contractor License is required. e) On-Call Maintenance: The selected Contractor shall respond to all on-call maintenance requests for the listed alarms. Requests may include but are not limited to repairs/updating of the existing fire alarm control panels, communicators and associated control equipment, power supplies, standby batteries and chargers, annunciator stations, equipment sensors, heat detectors, duct detectors, smoke detectors, fire dampers and related sensors, tamper sensors and other pertinent equipment. f) Alarm Notification: The selected Contractor will be responsible for the initial programming/reprogramming of all alarm panels to dial to the appropriate central station. The District will only compensate the selected vendor for one (1) programming visit per site. Any needed coordination with third party alarm vendors shall be accounted for in the vendor’s proposal and planned for in advance. Please note that there

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS