Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Homeland Security was posted on July 14, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

FIRE HYDRANT REPAIRS

Closed
70Z0241QPRW021Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont, North Carolina, with an estimated value of 16,690,000 dollars. The scope of work involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and comprehensive upgrades to the Morgans Branch Pumping Station. Key infrastructure improvements include the installation of a new wet well, valve vault, and associated appurtenances, as well as the demolition of existing pumps and piping. The contractor is responsible for delivering a fully operational facility, including the installation of pumps, a generator, odor control equipment, new gravity sewers, and manholes, while managing by-pass pumping, testing, and commissioning. The contract will be awarded to the responsible bidder submitting the lowest responsive bid, with a strong emphasis on MWBE compliance through the submission of Good Faith Efforts and Table A documentation. Bids are due by November 12, 2026, and must be submitted using the EJCDC C-410 Bid Form. The project is governed by EJCDC standard general and supplementary conditions, requiring performance and payment bonds and proof of insurance. Technical standards include AWWA Specification C-600 for pipelines, NEMA MG1 for motors, and AWS D1.2 for aluminum welding. Project administration is managed by the City of Belmont with Willis Engineers serving as the project engineer. Payment is processed via Applications for Payment, with terms set at 30 days after presentation to the owner.
Don Moorhead Construction, Inc.

POSTED

about 8 hours ago

DEADLINE

in 20 days

General Info

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

Buzzards Bay, MA, 02542, USA

Set-Aside

SBA

Documents

3

CONSTRUCTION+WAGES+FOR+NEW+HAVEN+CT.txt

TXT

Fire+Hydrant+SOW_.docx

DOCX

SF18+REQUEST+FOR+QUOTATION+-+FIRE+HYDRANT+REPAIR+-+SECTOR+LONG+ISLAND.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → Base Cape COD(00052)
Contacts2 people available
OfficeBUZZARDS BAY, MA, 02542, USA
Office AddressBUZZARDS BAY, MA, 02542, USA

Full Description

Show more
The scope of work for this project includes all personnel, equipment, tools, materials, supervision, and other items and services necessary to remove and replace a fire hydrant at USCG Sector Long Island Sound. The contractor must perform to the standards in this contract 1.2 Location of Site: U.S. Coast Guard Sector Long Island Sound is located at: 120 Woodward Avenue New Haven, CT 06512

More opportunities from Department Of Homeland Security → Base Cape COD(00052)

Same awarding agency

NAICS: 541990
Federal
FUEL TANK INTEGRITY TESTING
Solicitation # 31125PR260000720
The contract requires the contractor to perform comprehensive external and internal inspections of aboveground fuel tanks and potassium sodium tanks at USCG Base Cape Cod in Bourne, MA, over a four-year period with a base year and three option years. The scope includes external inspections of six aboveground fuel tanks—two 10,000-gallon gasoline tanks and three JP-8 aviation fuel tanks (one 30,000-gallon and two 15,000-gallon)—as well as two 5,000-gallon potassium sodium tanks located behind Building 124. Internal inspections and wall thickness measurements are required only on the 30,000-gallon and two 15,000-gallon JP-8 tanks adjacent to Taxiway Delta, and all work must comply with Steel Tank Institute SP001 and API 653 standards. The contractor must deliver detailed reports on tank conditions, including observed deterioration, test results, and estimated remaining service life, along with repair cost estimates. All work must adhere to Federal, State, and Local environmental regulations, with full compliance to OSHA standards and directives from the Base Safety Officer and Fire Department. The contractor is required to provide all personnel, equipment, materials, and supervision, with a licensed supervisor present onsite at all times who must be able to read, write, and speak English and have authority to approve minor modifications under $2,000. All personnel must be skilled and experienced. Prior to access, employees must undergo an NCIC background check, with personal information submitted seven days in advance, and all vehicles must meet Base entry requirements including valid insurance, registration, and driver’s license. The contractor must submit a Schedule of Work for approval before starting, complete daily logs submitted weekly, and submit a Safety Plan and Environmental Protection Plan—including a Storm Water Protection Plan—within 15 days of award, along with a Base Access Request Form within five days. Acceptance by the Contracting Officer’s Representative is mandatory and contingent upon site cleanup, punch list resolution, and all deliverables being submitted via approved forms. The contract mandates compliance with FAR 52.212-4, 52.222-90 (addressing DEI discrimination), and 52.246-21, and places full responsibility on the contractor for any damage to property, requiring repairs at their expense to original condition. Invoices must be submitted through IPP.gov, and
All Other Professional, Scientific, and Technical Services

POSTED

4 months ago

DEADLINE

N/A
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS