Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on December 28, 2017. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Forced Air Cooled Adjustable Load Bank

Awarded
N64498-17-T-5167Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Department of Defense, through the NSWC Philadelphia Division, is soliciting bids for a Forced Air Cooled Adjustable Load Bank under solicitation number N64498-17-T-5167. The project requires a resistive load bank featuring factory-standard over-temperature cutouts for safety and a local control panel utilizing any standard commercial interface. While contractors must provide specifications for all equipment interfaces, they are not required to supply cables or male cable terminations. Technical requirements for outdoor ratings, monitoring capabilities, and remote software are detailed within the Statement of Work. The remote operation software must be compatible with Windows 10 and capable of continuous data recording based on the available hard drive capacity of the user's computer. The response deadline for this award notice was set for August 9, 2017, with delivery schedules specified in the request for quotation.

General Info

Contract Value

$63,135

NAICS

N/A

Place of Performance

PA, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Combined Synopsis

Notice updated

The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Nswc Philadelphia Division
Contacts1 person available
OfficePHILADELPHIA, PA, 19112-1403, USA
Office AddressPHILADELPHIA, PA, 19112-1403, USA

Full Description

Show more
The purpose of this post is to answer the following questions: Q: What is the timeline for needing the equipment? A: The delivery schedule can be found on page 5 of the RFQ. Q: How much cable is required? A: There is no requirement for cable. Q: What type of terminations on the cable are required? A: Contractors shall provide the specifications for all equipment interfaces but does not have to provide the cable or male cable terminations (plugs). Q: Is the load bank to be designed for operation and/or stored in the rain? A: Outdoor rating is delineated in Section 8 of the SOW on page 4. Q: Are volt and current meters to be provided on the load bank for local control? A: Monitoring requirements are delineated in Section 15 d of the SOW on page 4. Q: What type of equipment will the remote software run on? A: Software is delineated in Section 15 b of the SOW on page 4. Q: Does the local control panel use toggle switches, membrane switch or digital screen? A: It can be any commercial option. Q: How much data needs to be stored? A: The total amount of data stored is a function of the Windows 10 remote operation computer hard drive capacity. The software should be able to record data continuously as long as enough memory remains in the computer (not to be supplied in this RFQ). Q: Is an overtemperature sensor and shut down to be provided on the load bank with provisions for remote indication? A: It is the Government's understanding that over temperature cutouts are industry standard on resistive load banks. The Government would anticipate that from a safety perspective, this functionality would be built as factory standard. Q: Will the Government provide a bid extension to July 16, 2017? A: The due date remains unchanged as a result of these questions.

More opportunities from Department Of Defense → Nswc Philadelphia Division

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS