Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

FSS REPAIRS TO FIRE WATER DISTRIBUTION SYSTEM, VARLOCS (QC1022 PHASE 4)

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac Far EastView Agency

NAICS

N/A

Place of Performance

USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Far East
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Far East
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Project will perform the following: 1]. Replace 9-ea fire hydrants (FH93, FH95, FH96, FH97, FH100, FH101, FH102, FH94 and FH92) complete with fittings and all required accessories, 2]. Install new underground pipelines approx. 308-lf, 6" dia. complete with valves, fittings, valve box cover and all required accessories of fire hydrants; (FH93, FH95, FH96, FH97, FH100, FH101, FH102, FH94 and FH92), 3]. Install underground fire protection pipelines approx. 97-lf, 6" dia. Complete with pipe fittings, and all supported accessories connected from main line near PIV to F-4081, 4]. Install new 1-ea gate valve, 6" dia. and 1-ea PIV (post indicator valve) complete with all required accessories from main line to F-4081 5]. Replace underground fire protection pipelines approx. 104-lf, 6" dia. Complete with pipe fittings, and all supported accessories connected from main line near PIV to F-4005, 6]. Install new 1-ea gate valve, 6" dia. and 1-ea PIV (post indicator valve) complete with all required accessories from main line to F-4005, 7]. Replace underground fire protection pipelines approx. 104-lf, 6" dia. Complete with pipe fittings, and all supported accessories connected from main line near PIV to F-4008, 8]. Install new 1-ea gate valve, 6" dia. and 1-ea PIV (post indicator valve) complete with all required accessories from main line to F-4008, 9]. Replace underground fire protection pipelines approx. 88-lf, 6" dia. Complete with pipe fittings, and all supported accessories connected from main line near PIV to F-4004, 10]. Install new 1-ea gate valve, 6" dia. and 1-ea PIV (post indicator valve) complete with all required accessories from main line to F-4004, 11]. Replace underground fire protection pipelines approx. 88-lf, 6" dia. Complete with pipe fittings, and all supported accessories connected from main line near PIV ... NOTE: description has been truncated, please see Project Note for full description.