Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, June 24 at 2:00 PM EDT

Register Free →

General Services Administration (GSA) Seeks to Lease the Following Space in Bozeman, MT

Active
4MT0170Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The General Services Administration (GSA) is seeking to lease office space within the city limits of Bozeman, Montana, with a size requirement between 2,350 and 2,468 ABOA square feet. The lease term extends up to 180 months, with a firm commitment of 120 months. The space must be contiguous, preferably located on the second floor or higher, and comply with stringent security criteria including forced entry protection, specialized window treatments, and secure perimeter construction aligned with Wall Type A7 specifications. Additional features include supporting floor loads for heavy file safes, 24/7 access with elevator override control, and strict limitations on proximity to hazardous materials or undesirable neighboring facilities. Parking provisions require a total of three spaces, with high standards to prevent access near the tenant perimeter for certain facility security levels. Interest submissions must include comprehensive building details such as ownership, available square footage, rental rates inclusive of tenant improvements, existing energy efficiency measures, and on-site parking arrangements. The offered space must meet federal fire safety, accessibility, seismic, and sustainability standards, and be located outside the 100-year floodplain. The Government currently occupies space in Bozeman under a lease that will expire, and seeks alternatives that offer economic advantages without significant relocation costs or operational downtime. Responses are due by June 29, 2026, with anticipated occupancy starting February 1, 2027. The leasing specialist for this opportunity is Amy Hascall, who can be contacted via email for further information.

General Info

GSA seeks 2,350-2,468 sq ft secure Bozeman office, 120-month lease, parking, due June 29, 2026.

Agency

General Services Administration → Pbs Office Of Leasing

NAICS

531120 - Lessors of Nonresidential Buildings (except Miniwarehouses) View NAICS

Place of Performance

Bozeman, MT, USA

Set-Aside

NONE

Documents

(1)

4MT0170+Delinated+Area+Map+Draft.png

PNG

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyGeneral Services Administration → Pbs Office Of Leasing
Contacts1 person available
OfficeWASHINGTON, DC, 20405, USA
Organization / Agency
General Services Administration → Pbs Office Of Leasing
Office AddressWASHINGTON, DC, 20405, USA
Contacts

Full Description

Show more

State: Montana


City: Bozeman


Delineated Area: City boundaries of Bozeman, MT *See DA map attached*


Minimum Sq. Ft. (ABOA): 2,350 SF


Maximum Sq. Ft. (ABOA): 2,468 SF


Space Type: Office


Parking Spaces (Total): 3


Full Term: 180 months


Firm Term: 120 months


Additional Requirements:


SPACE REQUIREMENTS


A. All space must be contiguous, and preferably on the 2nd floor or higher. Space on the first floor
will be considered only when no other space is available, or if deemed appropriate by Tenant.
First-floor spaces require additional security measures.
B. If the exterior skin of the building is not of substantial construction as determined by Tenant
Security (e.g., concrete, filled CMU) and does not meet Tenant’s forced entry protection
requirements, interior assembly of perimeter walls must be constructed in accordance with Wall
Type A7 specifications.
C. All exterior perimeter windows must have fragment retention film, except at SCIF Rooms, which
must have film rated for RF/IR shielding and blast film.
D. All perimeter windows less than 18’-0” from grade or accessible platform (e.g., air conditioners,
fire stairs, adjacent roofs, ledges, or windows) must have forced entry protection such as
manbars or security screening. Assessment of accessible platform(s) will be determined by
Tenant Security.
E. Design of workstation must ensure computer monitors do not face exterior windows.
F. Roofs less than 18’-0” from grade or accessible platform must meet the same forced entry
protection and sound attenuation requirements as the building’s perimeter walls. Metal roofs
less than 18’-0” from grade or accessible platform must be 18-gauge or greater to meet the
same forced entry protection and sound attenuation requirements as perimeter walls.
G. Metal structure buildings that will have an “Open Storage Secure” security posture must have
the secured perimeter constructed to meet forced entry protection requirements, Wall Type A7,
or approved equivalent by Tenant and CO.
H. If the space and/or building are of wood joist construction or in an historical building, additional
security measures will be required and must be approved by Tenant Security.I. Skylights must be removed or secured against forced entry, blast, and visual observation.
J. Where Tenant space adjoins another building, tenant, or public areas, perimeter walls of
Tenant space must be constructed slab-to-slab in accordance with the diagram for Wall Type
A7. All conduits, backboxes, and electrical devices on Tenant demising wall must be surface
mounted on the secure side. Surface mounting is not required if non-secured side of Wall Type
A7 is available for inspection by Tenant.
K. No telephone lines, data lines, electrical service, plumbing service, or ducts other than that
required for Tenant are permitted to pass through the space, except with specific approval from
Tenant and CO or when routed through building space (such as electrical or telephone closets
dedicated to that use). All wiring, conduits, and pipes running through the space and not
serving Tenant’s needs must be removed and/or rerouted. If wiring, conduits, and pipes must
not be removed and/or rerouted, they must be enclosed with a construction assembly compliant
to secure wall requirements.


L. Future ceiling, floor slab, or demising wall penetrations through Tenant’s secured perimeter will
not be permitted.
M. If floor slab does not extend to the skin of the building, additional security measures will be
required to meet forced entry protection, Tenant Security sound attenuation requirements, and
RF requirements.
N. The space will be provided with file safes weighing between 850 lbs and 1,000 lbs each.
Although safes will be dispersed throughout the office, floor load of the proposed site must be
capable of supporting this additional weight. The quantity and location of safes may change
over the course of the lease. The Lessor shall provide the Tenant with a floor plan showing
locations where the safes can be located.
O. Tenant’s regular business hours are 7:00 AM to 5:30 PM; however, 24-hour access to the
space and any provided elevator service must be available 365 days per year.
P. One (1) elevator must be provided with override control. If the office is located on the 6th floor
or above, elevator must be on emergency power.


SITE REQUIREMENTS


A. Proposed site must not be within 640’-0” of any facilities identified by ISC as “hazardous
materials transportation/storage facilities.”
     1. Hazardous locations include facilities with potential environmental threats (e.g., fuel storage
     areas, gas stations, chemical manufacturing facilities, and railroad lines transporting
     hazardous material).
    2. Special consideration should be given to exclude sites located near hazardous areas, such
    as bulk storage sites (e.g., hazardous materials storage sites, water purification centers,
    above-ground fuel storage, and rail yards).
3. It is preferred that the proposed facility not be located near “Low Risk Facilities” (e.g., day
care centers, senior centers, schools, hospitals, and religious/rehabilitation/social service
centers).
B. Proposed facility must not be located within 400’-0” of public defenders, ICE, probation offices,
IRS, universities, other businesses, or facilities, deemed unacceptable by Tenant Security for
safety purposes. This requirement may be waived by Tenant Security if no other facility is
deemed acceptable. In those cases, enhanced security requirements may be necessary.
C. Proposed Tenant spaces or facilities within 400’-0,” or adjacent to facilities associated with
foreign powers identified in Tenant's National Security Threat List, will not be considered.
D. For proposals of new construction of a standalone facility:
     1. Standoff distance may be required from defended perimeter to the façade of the building to
      house the Tenant office, if required by FSL rating.
      2. Defended perimeter must be measured as the distance from building to boundary
      protected by bollards, planters, or other barriers approved by Tenant.
E. For proposals of space in existing buildings, standoff distance must be provided from the curb
line or nearest point accessible by a vehicle to the façade of the building to house the Tenant
office.


F. Space shall have a minimum setback of at least 20 feet, where the setback will be measured from the interior perimeter wall of occupied Tenant space to any point where an unscreened or otherwise unauthorized vehicle can travel or park.  This requirement may be waived by Tenant Security.


PARKING


A. Uncontrolled underground or uncontrolled under-building parking is not permitted for facilities
with FSL III, IV, or V ratings. A standalone or mixed-tenant facility with uncontrolled
underground or under-building parking should not be considered for a facility with an FSL I or II.
B. A mixed-tenant facility with public parking withing 30 feet of the interior perimeter wall must not
be considered for a facility with an FSL III, IV, or V rating. A mixed-tenant facility with public
parking within 20 feet of the interior perimeter wall must not be considered for a facility with an
FSL I or II rating.
C. A stand-alone facility with public parking within 100 feet of the facility must not be considered
for a facility with an FSL III, IV, or V rating. This requirement may be waived by Tenant Security
if no other facility is deemed acceptable. In those cases, enhanced security requirements may
be necessary.


Expressions of interest must include the following information: 


Building name and address and location of the available space within the building


Rentable square feet available and expected rental rate per rentable square foot, fully serviced


ANSI/BOMA office area (ABOA) square feet to be offered and expected rental rate per ABOA square foot, fully serviced.


Indicate whether the quoted rental rate includes an amount for tenant improvements and state the amount (if any)


Date of space availability


Building ownership information


Amount of parking available on-site and its cost. Include whether expected rental rate includes the cost of the required Government parking (if any)


Energy efficiency and renewable energy features existing within the building


List of building services provided.


The U.S. Government currently occupies office and related space in a building under a lease in Bozeman, MT, that will be expiring. The Government will consider alternative space if economically advantageous. In making this determination, the Government will consider, among other things, the availability of alternative space that potentially can satisfy the Government’s requirements, as well as costs likely to be incurred through relocating, such as physical move costs, replication of tenant improvements and telecommunication infrastructure, and non-productive agency downtime.


Offered space must meet Government requirements for fire safety, accessibility, seismic, and sustainability standards per the terms of the Lease.  A fully serviced lease is required.  Offered space shall not be in the 100 year flood plain.


Entities are advised to familiarize themselves with the telecommunications prohibitions outlined under Section 889 of the FY19 National Defense Authorization Act (NDAA), as implemented by the Federal Acquisition Regulation (FAR).  ).  For more information, visit: https://acquisition.gov/FAR-Case-2019-009/889_Part_B.


Expressions of Interest Due: Monday, June 29, 2026; 5:00PM PST


Market Survey (Estimated): TBD


Occupancy (Estimated): February 1, 2027


Send Expressions of Interest to:


Amy Hascall, Leasing Specialist


Email Address: amy.hascall@gsa.gov


Government Contact Information


Lease Contracting Officer: Joel Wilson


Leasing Specialist: Amy Hascall

Similar Contracts

NAICS: 531120
New
SLED
WANTED TO LEASE BY THE STATE OF CALIFORNIA - Santa ClaritaThe State of California, through the Department of Consumer Affairs and the Department of General Services, is seeking to lease approximately 2,745 net usable square feet of office space in Santa Clarita, Los Angeles County, along with parking accommodations. The desired property must meet several specific criteria: it should be asbestos hazard-free at the time of occupancy, comply with state regulatory standards including seismic safety, ADA accessibility, California Building Code, and Title 24. Additionally, the site should be near public transportation and fulfill Disabled Veteran Business Enterprise requirements. Preference will be given to buildings demonstrating LEED or Energy Star certification where cost-effective, reflecting the State’s emphasis on sustainable building practices. The parking requirement includes sixteen non-exclusive spaces and three exclusive electric vehicle charging stalls. The proposed leasing area is bounded by Newhall Ranch Road to the north, Valencia Boulevard to the south, McBean Parkway to the east, and The Old Road to the west. Interested property owners or authorized agents must respond by July 3, 2026, providing property details including address, map, and project number to the Department of General Services contact person, Edem Kuevor. This solicitation seeks compliant commercial real estate offerings and does not constitute legal representation of the State in real estate transactions. All responses should be submitted via email or written correspondence as specified.
California Department of General Services

POSTED

1 day ago

DEADLINE

in 17 days