Gordon Bernell Charter School is soliciting bids for the procurement and installation of network equipment and cabling across two locations, MDC and 4th Street. The project requires a comprehensive solution including Cat 5 and Cat 6 cabling, Ruckus Wireless Access Points, outdoor brackets, and a wireless bridge with a minimum capacity of 500Mbps to connect two buildings approximately 300 feet apart. The scope of work encompasses power protection, internet security with CIPA filtering, and the installation of a secure data cabinet, with all new wiring to be installed in ceilings or outdoors rather than existing conduits. Bidders must submit their responses to frank@erateallstars.com using the specific school name and Form 470 number in the subject line to avoid disqualification. Proposals should clearly identify any ineligible charges, taxes, or surcharges, and providers are encouraged to indicate if they can invoice USAC directly. The project involves various Category 2 internal connections and basic maintenance services, with installation schedules to be coordinated with site contacts to ensure safety and minimal disruption to school operations.
General Info
Place of Performance
Albuquerque, NM, 87107, USASet-Aside
Documents
0AI Contract Breakdown
Uniform Contract FormatNo documents to break down
The breakdown needs solicitation documents. None were found from this contract's source.
Timeline
Submission Closed
Organization & Contact Information
Full Description
Cabling - Cat 5 Qty 1 100ft or equivalent - Cat 6 Qty 1 25ft or equivalent - Computer/Wireless Network Qty 8 1600ft or equivalent
Racks - Outdoor Bracket - Street and Power mount or equivalent
WAPs - Ruckus WAPS Qty 8 or equivalent
Wireless Bridges - 2 devices for 1 bridge
Please note that this is all new wiring and not in existing conduits. For MDC it is in Ceiling. For 4th street its going from one building to another for the wireless bridge and will be outdoor for the new area, and a bit outdoors for the main building. The area should be accessible during normal hours for the new building. We will have to verify the main building if during school hours.
The Outdoor bridge for 4th street P300 and for MDC Ruckus R670. The capacity of the bridge should be at least 500Mbps and the distance is about 300ft.
All bid responses or questions should be sent to frank@erateallstars.com. Although not a mandatory requirement, service providers should indicate if they are willing to invoice USAC directly, providing the school with the applicable discounts on their monthly billing. The email subject of your response should be titled with the [school/library/district] name and Form 470 # for which you are bidding. The school, at their discretion, may reject responses sent to the incorrect email address and/or with the incorrect email subject . All ineligible charges must be clearly identified and cost-allocated. If applicable, also list any taxes, fees, or surcharges. Any bids that do not address the actual services or equipment requested on this form will be automatically disqualified.
Requested services (27 line items): - Category 2 — Basic Maintenance Of Internal Connections — Cabling - Category 2 — Basic Maintenance Of Internal Connections — Wireless Access Points - Category 2 — Internal Connections — Racks - Category 2 — Managed Internal Broadband Services — Existing Equipment - Category 2 — Internal Connections — Wireless Access Points And Necessary Software And Licenses - Category 2 — Basic Maintenance Of Internal Connections — Antennas, Connectors, And Related Components - Category 2 — Internal Connections — Cabling - Category 2 — Internal Connections — Antennas, Connectors, And Related Components - Category 2 — Basic Maintenance Of Internal Connections — Racks
Reference documents (Form 470 / RFP): https://publicdata.usac.org/EPC/Prd/Form470/260020119/16056582/21297308-USAC_FCC_FORM_470_APPLICATION_260020119_CERTIFIED.pdf, https://publicdata.usac.org/EPC/Prd/Form470/260020119/16056582/21297184-Cat2SOWGordonBernellErate3326.docx, https://publicdata.usac.org/EPC/Prd/Form470/260020119/16056582/21297157-Cat2CostSheetGordonBernell.xlsx, https://publicdata.usac.org/EPC/Prd/Form470/260020119/16056582/21296921-Cat2_Cost_Sheet_GordonBernell_3326.xlsx
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS