Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on April 29, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H335--Boiler Useful Life Studies Hershel “Woody? Williams VAMC 581-24-3-507-0377

Closed
36C24524Q0485Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

541380 - Testing Laboratories and Services

Place of Performance

Department of Veterans Affairs Hershel “Woody�? Williams VAMC 1540 Spring Valley Drive, Huntington, MD, 25704

Set-Aside

NONE

Documents

1

Boiler Useful Life Studies - Hershel Woody Williams VAMC (36C24524Q0485)

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Office AddressLINTHICUM, MD, 21090, USA
Contacts
Bill PrattContract Specialist

Full Description

Show more
SUMMARY: Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for information/sources sought notice in order to identify vendors that are interested in and capable of performing a Condition Assessment Studies (Boiler Useful Life Studies) on Boilers #1, #2 and #3. Located at the Hershel Woody Williams VAMC located at 1540 Spring Valley Drive, Huntington WV, 25704. DESCRIPTION OF WORK: BACKGROUND The Huntington VAMC needs a vendor to perform Condition Assessment Studies (Boiler Useful Life Studies) for 3 (three) onsite boilers, which are in Bldg. 3. These studies determine overall condition and safety of the equipment. SCOPE OF WORK Vendor will provide all parts, labor, equipment, and material for inspection, examination, condition evaluation and reporting of three (3) onsite boilers: Boiler #1, Manufacturer: Johnston, Date: 1989, Model: PFTA 509, Type Fire Tube -4 Pass, Size: 400HP, Normal OP: 90psi Boiler #2 Manufacturer: Kewanee, Date: 1998, Model: H35-350-G02-LE-200 Type: Fire Tube -3Pass, Size: 350HP, Normal OP: 90psi. Boiler #3 Manufacturer: Kewanee, Date: 1998, Model: H35-300-G02-LE-200 Type: Fire Tube -3 Pass, Size: 300HP, Normal OP: 90psi. Tasks to be accomplished: 1. Vendor will work with the Boiler Plant (Chris Lemon / +1 (555) 000-0000 x2360) to: Review plant safety regulations and lockout/tagout procedures Review equipment background information including safety relief valve data, manufacturers data sheets (if available), operating logs, maintenance and repair records, prior inspection data, and original or revised drawings. Comprehensive internal/external visual inspection of the boiler, boiler tubes, and casings/enclosure Ultrasonic measurements of the shell and tubesheet thicknesses for the determination of estimated rates of material depletion and working pressure projections Magnetic Particle Testing weldments on each tube sheet will be examined for surface discontinuities that may be indicative of cracking. Review the findings of the inspection team. Make specific recommendations concerning safety and/or maintenance concerns which should receive attention prior to object closure or operation. 2. The Vendor is responsible to leave the areas clean and organized daily. 3. Provie official Report within thirty [30] business days following site departure. This report will document the preliminary inspection report results plus: Observations and results of assessment activities Specific inspection results Probable causes and the significance of noted deficiencies. Recommendations based on inspection/evaluation results. Sketches and/or photographs documenting inspection findings. Evaluation of conditions relative to original design and current operating parameters All nondestructive test measurements and findings SUPPORTING INFORMATION Place of Performance The VAMC located at 1540 Spring Valley Drive, Huntington WV 25704. Period of Performance The Contractor shall perform all work during normal business hours, (unless other times are stipulated by the Contracting Officer s Representative (COR). Special Considerations Contractor Furnished Materials All labor, materials, equipment to perform the job. When furnish , provide , install , or similar term is used it shall mean a complete installation, ready for use. The vendor shall supply all parts, equipment, material, and labor to conduct work as listed in the Statement of Work above. The work will include all items as described in the Scope of Work listed above. Interested & Capable Responses: NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for the Hershel Woody Williams (VAMC). Please respond to this RFI/Sources Sought 36C24524Q0485 with your: Business name (including Unique Entity ID (SAM.gov) - Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and - Person of contact (including telephone number & email address). - Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities. - Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable NAICS) Brief Summary of categories of services that your company can/cannot provide. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable) Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response: - Do you intend to self-perform this effort? If you are located outside the immediate area, how will you self-perform? Or do you intend to subcontract work under this contract? If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting? - Response Instructions: Responses must be submitted by 13:00 PM (ET) May 2nd, 2024. Responses to the information requested above must be submitted via email to Bill Pratt at contact@example.gov. This request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred as a result of a vendor s attendance to the Site-Visit nor the preparation of responses submitted as a result of this notice. Bill Pratt Contract Specialist VHA, NCO 5 contact@example.gov

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 561210
New
Federal
J044--NOTICE OF INTENT TO SOLE SOURCE Baltimore VAMC Steam System Preventive Maintenance from Vicinity Energy Baltimore Corporation
Solicitation # 36C24527Q0048
The Department of Veterans Affairs is issuing a Notice of Intent to Sole Source for an open market award to Vicinity Energy Baltimore Corporation to provide annual steam system preventive maintenance at the Baltimore VA Medical Center. This requirement, classified under NAICS code 561210 and PSC J044, is driven by the fact that the facility's steam equipment is directly connected to the district steam distribution system owned and operated by Vicinity Energy. Due to this interconnected configuration and the proprietary operational data involved, the government identifies Vicinity Energy as the sole source capable of ensuring the reliable operation of the system without risking the broader distribution network. The scope of work requires a two-person crew to provide eight hours of service every two weeks, totaling 416 labor hours per year. Key responsibilities include steam trap surveys, cleaning pressure-reducing valves, inspecting heat exchangers, and ensuring proper water chemistry and meter operation. The contractor must supply all necessary parts meeting original manufacturer specifications and provide emergency call-back services with a technician on-site within five hours of notification. The anticipated period of performance is one year from the award date, with the possibility of option-year extensions. Interested vendors may submit capability statements to Contract Specialist Patricia Thai by 11:00 AM EST on November 10, 2026, referencing announcement number 36C24527Q0048. These submissions will be used solely to determine if the procurement will be conducted on a competitive basis. All work will be performed at the Baltimore VAMC, adhering to strict VA security, safety, and infection control requirements.
Facilities Support Services

POSTED

1 day ago

DEADLINE

in 12 days
View Details
NAICS: 423440
New
Federal
J072--JR/BP POTS AND PANS ROOM | WASHINGTON DC VAMC
Solicitation # 36C24527Q0043
The Department of Veterans Affairs is seeking a contractor for the emergency procurement, delivery, and factory assembly of commercial-grade kitchen equipment for the Nutrition and Food Services Pot and Pan Washing Room at the Washington DC VA Medical Center. This firm-fixed-price acquisition is driven by critical infection control and physical environment deficiencies identified during a June 2026 Joint Commission survey. The required equipment includes a custom Aerowerks two-compartment sink system with a drainboard, a Salvajor food waste disposer, and a Hobart TurboWash II pot scrubber. All equipment must be NSF listed, commercial grade, and compliant with Joint Commission, CMS Conditions of Participation, and FDA Food Code standards. The contractor is responsible for freight, uncrating, and delivery to the facility within 60 calendar days of award. A qualified Aerowerks technician must perform the on-site assembly within 14 days of delivery to preserve the manufacturer warranty. Strict safety and cleanliness protocols are in effect, including the requirement for hot work permits for welding and the immediate removal of all packaging and metal debris to prevent food service contamination. Payment will be issued via a single electronic invoice on a Net 30 basis following the COR's written acceptance of the installed and inspected equipment.
Other Commercial Equipment Merchant Wholesalers

POSTED

3 days ago

DEADLINE

in 6 days
View Details
NAICS: 238210
New
Federal
J061--INTENT TO SOLE SOURCE AWARD TO EATON CORP - BASE YEAR MAINTENANCE AND SERVICE CONTRACT FOR 8 UPS HERSHEL WOODY WILLIAMS VAMC
Solicitation # 36C24527Q0046
The Department of Veterans Affairs intends to award an open market sole source contract to Eaton Corporation (UEI: NP3NSFVMNUM3) for a one-year service and preventative maintenance agreement. The contract covers eight specific Eaton UPS systems located at the Hershel Woody Williams VA Medical Center in Huntington, West Virginia. The scope of work includes a Flex Plan consisting of two UPS and two battery preventive maintenance checks for all eight systems. This procurement is classified under NAICS code 238210 for Electrical Contractors and Other Wiring Installation Contractors and PSC J061 for the maintenance and repair of electric wire and power distribution equipment. The government is pursuing a sole source award because Eaton Corporation is the original equipment manufacturer and the only authorized provider of the proprietary service software, repair documentation, and materials required for 3-phase Eaton UPS products. As an ISO9001 certified supplier, Eaton does not certify or support third-party providers for these specific products. This notice is published in accordance with FAR 5.101(a) and FAR 12.102. Interested vendors may submit capability statements to Contracting Officer William Pratt by November 12, 2026, at 10:00 AM ET, referencing announcement number 36C24527Q0046 to determine if the requirement will be competed.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

3 days ago

DEADLINE

in 14 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS