Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on June 25, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H966--Department of Veterans Affairs VISN 4 Blood Lab Services

Closed
36C24424Q0781Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 325413
New
DIBBS
CULTURE MEDIUM, THAYER-
Solicitation # SPE2DS-27-T-1066
Solicitation SPE2DS-27-T-1066 is a request for quotations issued by the DLA Troop Support Medical Supply Chain for the procurement of one package of Thayer-Martin Modified (MTM II) Agar culture medium, identified by NSN 6550-01-711-1542. This dark brown, ready-to-use plated medium is specifically designed for the isolation of pathogenic Neisseria from specimens containing mixed flora of bacteria and fungi. The product is delivered in packages of 100 plates and requires strict refrigeration storage between 2 to 8 degrees Celsius (36 to 46 degrees Fahrenheit) and must not be frozen. The contract mandates a non-extendable shelf life of three months, with a requirement that no more than 14 days elapse between the date of manufacture and the date of delivery to the government. Delivery is set for JBER, Alaska, with a required delivery date of October 27, 2026, under FOB Destination terms. Packaging must be commercial and sealed to prevent damage, with marking adhering to Medical Marking Standard No. 1 and shelf-life labels following MMS1C. Administrative requirements include electronic invoicing via the Wide Area WorkFlow system and compliance with various FAR and DFARS clauses, including the Buy American Act, Berry Amendment, and safeguarding of covered defense information. Evaluation will consider technical data for any alternate products offered and may include HUBZone price evaluation preferences. Inspection and acceptance will occur at the destination.
MEDICAL SUPPLY CHAIN MD SURG FSF

POSTED

1 day ago

DEADLINE

in 5 days
NAICS: 325413
New
Federal
6550--Optilite analyzer reagents
Solicitation # 36C26227Q0052
The Department of Veterans Affairs, Southern Arizona Healthcare System, is soliciting a Firm-Fixed Price Blanket Purchase Agreement under solicitation 36C26227Q0052 for the procurement of FDA-approved reference testing reagents and consumables validated for use on the Optilite analyzer. The scope includes specific items such as Freelite Kappa, Freelite Lambda, and Ceruloplasmin reagents, as well as TENCELL cuvettes and sample cups. To ensure system performance and safety, all materials must be manufactured by Binding Site Laboratories, and substitutions are prohibited. The contract is issued as a full and open competition under NAICS code 325413, with a total estimated period of performance of sixty months, consisting of a base period from November 9, 2026, to November 8, 2027, followed by four one-year option periods. The award will be granted to the responsible offeror whose proposal is most advantageous to the government, based on a technical acceptability review of the Statement of Work and the lowest price. Deliveries are required to be made to various VA Medical Centers across Arizona, California, and New Mexico, with standard orders delivered within four working days of placement. All shipments must be destination-based, with the vendor assuming all shipping costs and adhering to strict packaging standards to prevent damage. Invoicing is handled electronically through the Department of Veterans Affairs Financial Services Center in accordance with the Prompt Payment Act. Quotes must be submitted via email to Contract Specialist Carlos Magana by November 4, 2026.
262-NETWORK Contract Office 22 (36C262)

POSTED

3 days ago

DEADLINE

in 6 days
NAICS: 325413
New
Federal
BPA - Consumable Supplies for Terumo Trima Accel Blood Collection systems
Solicitation # HT942627QE003
The Defense Health Agency is soliciting quotations to establish a Blanket Purchase Agreement (BPA) for the recurring resupply of consumable products for three Terumo Trima Accel Blood Collection Systems used by the USAISR Combat Casualty Care Research Team 1 in Texas. To maintain FDA approval and satisfy research protocols, the contractor must provide original manufacturer-supplied consumables, including Teruflex 500ml collection bags, Trima Platelet Kits, Isoplate Solution (PAS-F), TSCD Wafers, ACD-A Solution, and 150 mL couplers. This procurement is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 325413. The resulting BPA will have a 60-month ordering period with a total ceiling of 35 million dollars, though some documentation notes a lower limit of 350,000 dollars. Individual call orders are capped at 50,000 dollars, while Government Purchase Card orders are limited to 15,000 dollars. Awards will be made on a Lowest Price Technically Acceptable basis, with technical capability rated as pass or fail. All payment requests and receiving reports must be processed electronically through the Wide Area WorkFlow system. Quotations are due by November 6, 2026, and must be submitted in two separate volumes covering technical capability and pricing.
Army Medical Resources Acq Activity

POSTED

7 days ago

DEADLINE

in 8 days
NAICS: 325413
Federal
6550--VISN Cepheid GeneXpert Testing Supplies Base Plus 3 Op Yr RFQ
Solicitation # 36C24527Q0042
The Department of Veterans Affairs, specifically the VA North Atlantic Health Network (HSA 1.3), is soliciting a firm-fixed-price, Indefinite Delivery/Indefinite Quantity (IDIQ) contract for Cepheid GeneXpert testing supplies. This requirement covers the procurement of FDA-approved reagents, consumables, and service for PCR analyzers to detect various pathogens, including CoV-2, Influenza, RSV, MRSA, and Mycobacterium Tuberculosis. The contract is structured with a base period ending October 31, 2027, and three subsequent one-year option periods extending through October 31, 2030. Deliveries will be made to multiple VA Medical Centers across Maryland, West Virginia, and Washington DC. This acquisition is set aside for HUBZone small businesses. Award will be determined using the Lowest Price Technically Acceptable (LPTA) method, evaluating technical acceptability, delivery performance, past performance, and price, with additional credit given to certified SDVOSB or VOSB offerors. Key contractor requirements include being an authorized distributor, acknowledging orders within 24 hours, and guaranteeing a minimum four-month expiration date on reagents. Additionally, the vendor must provide an emergency plan to deliver replacement supplies within 24 hours if products are found to be defective. Invoices must be submitted electronically, and payments will be processed in accordance with the Prompt Payment Act.
245-NETWORK Contract Office 5 (36C245)

POSTED

8 days ago

DEADLINE

in 7 days

General Info

NAICS

325413 - In-Vitro Diagnostic Substance Manufacturing

Place of Performance

VISN 4, Erie, PA, 16504, USA

Set-Aside

NONE

Documents

3

Blood Gas SOW Attachments 2025

XLSX, High priority: read this first6 pages · sow
High

VA VHA and Radiometer America, Inc. Business Associate Agreement

PDF, Low prioritycontract-document
Low

VA VISN 4 Blood Lab Services Sources Sought

DOCX, Low priority15 pages · sources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseClosed
Posted

Sources Sought

Notice updated

Notice details unchanged. Attachments may have changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)
Contacts1 person available
OfficePITTSBURGH, PA, 15215, USA
Office AddressPITTSBURGH, PA, 15215, USA
Contacts
Christa StineContracting Specialist

Full Description

Show more
DISCLAIMER This Sources sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this sources sought. If you can provide the services as described in the below scope of work description please respond by Monday, July 22, 2024, at 3:00PM EST to contact@example.gov with the following information: Company Name Socio Economic Status: I.E. Small Business, Service Disabled Veteran Owned, Veteran owned, Women Owned, etc Email Address Phone Number Physical Address Capability statement pertaining to Scope of Work Limitations on Subcontracting will apply to the resulting solicitation. BPA Language: Intent: It is the intent of the Department of Veterans Affairs, (herein afterwards referred to as VISN 04) to establish a Blanket Purchase Agreement (BPA) for Blood Gas Testing. The Government will award a BPA to a single Contractor for Blood Gas Testing. Contractor agrees to the following terms of the BPA exclusively with the VISN facilities listed by Attachment and awarded in the final BPA. However, as requirements change, facilities within VISN 04 may be added or deleted by supplemental agreement of the Government and the Contractor. Additional tests/reagents/instrumentation may be added to the BPA as new technology becomes available. Prices and Terms: VISN 04 will provide an estimated volume by test for each individual medical center and outpatient clinic laboratory. Pricing is based in the AVERAGE daily test volume per instrument/analyzer for each facility. The Government estimates the volumes per facility but does not guarantee volumes as listed; they are estimates only. This will be a single award, firm-fixed price BPA with a 5-year period of performance and an optional 6-month extension. This BPA is not a contract. If the Contractor fails to perform in a manner satisfactory to the CO (Government Contracting Officer), this BPA may be canceled with thirty (30) days written notice to the Contractor by the CO. Period of Performance: VISN 4 intends to establish the base year of the agreement for the period of April 1, 2025, through March 31, 2030. Ordering Method: The participating facilities may order products via Electronic Data Exchange (EDI), telephone, facsimile or other written communication, identifying the products by number, quantity, purchase price, address for delivery, and any special instructions. Description/Specifications/Statement of Work Scope of Procurement: The desired instrumentation shall have the capability of performing or reporting the clinical parameters as defined in the statement of work. The instrument shall be able to simultaneously perform the testing as described below and meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). If Contractor offers a family of analyzers, the VISN 04 technical evaluation panel will determine if instrumentation proposed meets needs of using facility. Equipment shall be acquired for each of the clinical laboratories located at the listed VISN facilities. The Contractor is required to provide a continuously stocked inventory of reagents, standards, controls, supplies, disposables, and any other materials required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. Expiration date must be clearly marked on reagent, standards, and control containers. Unexpected changes in methodology/technology shall be at the expense of the Contractor. Alert/Notification of any delays in shipment as well as any or all technical advisory/recalls/alerts, prior to or simultaneously with field alerts should be forwarded to the designated individuals determined at contract award. Special handling for emergency orders of supplies: In the event that the supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery. The desired instrumentation shall have the capability of performing or reporting the clinical parameters as defined in the statement of work. The instrument shall have random access capability (if discrete testing is required) and be able to simultaneously perform the complete profile as described below and meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). Equipment must maintain, or preferably reduce the number of workstations or overall labor required to accomplish the required testing by each laboratory. If the Contractor offers a family of analyzers, VISN 4 technical panel will determine if instrumentation proposed meets the needs of the using facility. Equipment shall be acquired for each of the clinical laboratories at the VISN facilities listed in Attachment A. Definitions: Business Associate Agreement (BAA) A business associate is an entity, including an individual, company, or organization that, on behalf of VHA, performs or assists in the performance of functions or activities involving the use or disclosure of PHI, or that provides certain services involving the disclosure of protected health information (PHI). VHA is a covered entity under the HIPAA Privacy Rule (Privacy Rule). HIPAA regulations require VHA to execute HIPAA compliant BAAs with certain entities that receives, uses, or discloses VHA PHI, in order to perform some activity for VHA. These BAAs obligate VHA business associates to provide the same protections and safeguards to PHI that is required of VHA under the Privacy Rule. Parameter requirement: Blood Gas Analysis with Co-Oximetry Test Menu: Refer to Attachment A for desired test menu and estimated annual volumes. General Requirements: Primary analyzer(s) Base equipment offered that shall fully support the scope of operations (minimal requirements). Depending upon the technical functionality and the capabilities of the individual manufacturer s instrumentation, one analyzer or multiple analyzers may be required to meet the productivity specifications defined herein. In those instances, the additional analyzer(s) shall, likewise, be considered primary instrumentation and shall meet all the technical specifications of this solicitation. Those additional analyzer(s) offered meeting the definition of a primary analyzer shall be equivalent to a back up analyzer (see definition below) and shall replace the requirement for offering that category of equipment. Individual sites may choose to use a point of care instrument rather than a larger more complex analyzer. (Applies only if selected) Back up Analyzer(s) Equipment required in support of operations for the VA laboratories in the event the primary analyzer(s) becomes non operational/non functional. This category of equipment shall only be operated during periods of time when the primary instrumentation is not available for use. As such, the requirements for consumable supplies, i.e. reagents, quality control material, calibrators, etc., shall be minimal and corollary to the successful operation of the primary instrumentation. Specific tests that require back up performance are listed in Attachment A. Contractor shall provide quality control material at a minimum of two levels; normal and elevated/abnormal levels. Operational features - The instrument shall have the following: The capability of performing analysis on 100% of the tests listed. Tests include pH, blood gas, electrolyte, oximetry, and metabolite parameters. Sufficient capacity and throughput to meet the volume and service demands as defined in Attachment A. Safety features to avoid unnecessary exposure to biohazardous and chemical material. The exposure to and the volume of biohazardous and chemical material generated by the equipment must be minimal and require a minimum amount of handling. A bi-directional, barcoded computer interface compatible with the current VA laboratory information system. The fully operational interface (both hardware and software) shall be immediately available for implementation to the VA computerized hospital information system. The accuracy of the barcode reading must have less than a 1% failure rate. Equipment must be able to support multiple barcode formats (Code 39, Code 128) that may be enabled concurrently. Equipment must accept, at a minimum, BCBC characters in the specimen identifier that is alpha and/or numeric depending on site. Ability to prioritize STAT testing without compromising existing programmed testing. Minimal daily, weekly, monthly, and periodic maintenance. Ability to store and retransmit records (24 hours of maximal instrument throughput) in case of interface outage. Capability of analyzing small sample volumes (less than 3mL) Technical Features The instrumentation must be approved by the Food and Drug Administration (FDA) and shall have the following: On-board QC data management system with a minimum storage capacity of QC files including Levy-Jennings graphs. Analyzer must have the ability to capture, store, and electronically transfer QC data. Ability to monitor instrument performance. On-board reagent inventory system. Minimal carryover. Long calibration stability. Minimal reagent, calibrator, and control preparation. Ability to detect and alert operator to short samples. Ability to detect and alert operator to clotted samples. Ability to alert user and/or automatically discard empty/expired reagent containers. Minimal screen changes when manually programming samples for testing. Hardware Features The instrumentation shall have the following: A total equipment footprint that when installed in the laboratory shall not impact the functionality/operations of that laboratory. An on-board monitor/screen that is easily readable. A printer that has the capability of printing a patient report with patient demographic information that includes minimally the accession or unique identifier number (UID). An uninterruptible power supply with line conditioner for each instrument provided. Primary tube sampling. Specific Equipment Requirements The instrumentation shall have the following: Ability to comment on QC points to document troubleshooting and QC review. Ability to automatically program the performance of QC testing. Analyzer utilizes windows operating software. Equipment installation and possible reinstallation should the equipment need to be moved due to construction or laboratory redesign at no additional cost for one (1) location within each site. Primary and backup analyzers (for larger facilities) shall be from the same manufacturer and offer the same technology. Disk storage and/or submission of QC data for peer comparisons. Capability to detect out of range QC. Ability to view and print daily and monthly results and Levy-Jennings graphs. Ability to store QC values for second lot number during crossovers. Ability to retain QC data from second lot number when put into use. Consumables, Reagents, Calibrators, Supplies, and Disposables The contractor shall maintain on Government provided space a continuously stocked inventory of reagents, standards, controls, supplies, disposables and any other material or commonly stocked parts required to properly perform tests on the offered equipment. These items shall be of the highest quality ensuring sensitivity, specificity and tested to assure precision and accuracy. The quality of the products shall be high enough to satisfy proficiency testing standards of the College of American Pathologists (CAP) and The Joint Commission (TJC). In the event the consumables are found to be defective and unsuitable for use with the contractor's equipment, or the contractor has failed to comply with the requirements for routine supply delivery, the contractor shall deliver the consumable supplies within a period of twenty-four hours after receipt of the verbal order for priority delivery from the Government activity. If either circumstance has occurred, the contractor shall deliver to the site, in the most expeditious manner possible, without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the contractor's equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they will be honored by the contractor until the arrival at the Government site of the monthly standing order/routine supplies delivery. Failure to reserve adequate inventory may result in default. If assay is not available on manufacturer s equipment, third party reagents, controls, calibrators, and consumables must be included in the contract to accommodate the site s current test menu. Reagent Characteristics: Automatic calibration of most analytes. Liquid calibrators for most/all tests. Liquid reagents with very little or no reagent preparation for most/all tests. Reagents have prolonged shelf life and stability once opened/on-board. On-board reagent inventory. Instrument alerts operator to regents/consumables needed to complete testing. Vendor will characterize each method and provide exact vendor guaranteed minimum linearity/AMR, CRR limits. The vendor will supply enough reagents and supplies to analyze all patient tests, all quality control, proficiency testing, linearity, comparisons, and employee competencies per year. External quality control (must travel along the same route as patient samples including the sample inlet port) at least 3 levels per day Proficiency testing Linearity Method comparisons Competencies f. Contractor shall provide consumables in a manner that assures lab operations will not be interrupted should supplies not perform as expected. Laboratories shall be afforded one extra of each type of consumable such as quality control, membranes, reagents, calibrators, diluents, etc. to have on hand for these events. The Contractor will ensure a sound mechanism for reporting technical difficulties and timely distribution of identified replacements to keep testing downtime as brief as possible. Method Performance/Validation The instrumentation shall have the following: Method performance/comparison will be at the expense of the Contractor and will include linearity materials and reagents as required and based on manufacturer s specifications and be consistent with Clinical Laboratory Standards Institute (CLSI) guidelines and related documents, College of American Pathologists (CAP) standard, and Federal regulations. Correlations will be performed for each analyte using a minimum of 20 samples that span the reportable range. The Contractor will analyze results and provide statistical data to support acceptance of the new method. Statistics include at least the mean, bias, slope, y-intercept, correlation coefficient and meet current standards defined by CLSI. Precision study using abnormal material will be performed and shall consist of a within run precision study of 10 normal and 10 abnormal controls and a day-to-day precision study of normal and abnormal controls for 10 days for a total of 20 values per level. Can be run twice per day if necessary. Where applicable, intra-VISN facility variations should be kept at an absolute minimum. Sensitivity may be validated concurrently with correlation studies. Mathematical calculations to determine efficiency, sensitivity, false positive rates, and false negative rates are applied. Specificity studies will be done by review of product literature and assay inserts to determine adverse effects for increased bilirubin, hemolysis, lipemia, or other interrupting substances. Carryover Studies are required to ensure instrument properly flushes probes between specimens. Successful carryover studies shall be completed on all analyzers during installation. These studies shall be performed using either Contractor developed program(s) or program(s) developed by a third party (CAP/CLSI, formerly NCCLS). The program(s) shall be provided to each laboratory at no cost. Reference Range A reference range must be determined for each test following CLSI guidelines. Samples used for the reference range study must be representative of the patient population being tested. Reference range assessment must be performed for each lab. One of the following protocols shall be used: A verification of the manufacturer s suggested reference range may be performed as long as the suggested range is based on a comparable population of test subjects. The manufacturer shall provide specific information defining how the suggested range was determined. A minimum of 20 reference individuals shall be used to verify the manufacturer s range. Any apparent outliers should be discarded, and new specimens obtained to provide a statistically valid verification. If the suggested manufacturer s range is not appropriate for the patient population, a reference range shall be established. Establishing a reference must follow CLSI guidelines. This requires a minimum of 120 reference individuals to be used to establish a reference range. The reference interval should be determined using the nonparametric method. If a laboratory is currently using the proposed instrument/reagent system, the in-use reference range can be transferred to the new system if a method comparison study between the two systems proves to be acceptable. If comparison studies are not acceptable, one of the two above items must be performed. Reports The Contractor shall provide to the Contracting Officer (CO) and other individuals (designated post award) a copy of a quarterly report of sales, by ordering facility, within 30 calendar days after the close of each quarter s business. Reports are to reflect, at a minimum, total net sales amounts before discount, and discount amounts by ordering facility as well as the raw data used to develop these reports. These reports shall be used to monitor the commitment of each facility, reporting the savings realized and shall be shared with each participating facility, personnel associated with acquiring the products, and respective laboratory personnel. Additional invoice charges associated with reagent and/or supply wastage or repair parts included at no charge shall not be accepted. There will be no additional charges for any reports required as part of the BPA. Attachment C may be used as a template to provide these quarterly reports. Support Features Commercial marketing The equipment models being offered shall be current production as of the date this offer is submitted. For purposes of this solicitation, current production shall mean that the clinical laboratory analyzer model is being offered as new equipment. Discontinued models that are only being made available as remanufactured equipment are not acceptable. Start-Up Reagent The Contractor shall provide all reagents, calibrators, controls, consumable/disposable items, parts, accessories and any other item included on the list of supplies defined in the BPA and required to establish instruments for operation for performance of acceptable testing. The Contractor shall perform, to the satisfaction of the Government, all validation studies including precision, method comparison with current analyzer, accuracy (recovery), linearity (reportable range), calibration verification, verification of reference interval, and determination of sensitivity and specificity at no cost to the Government. The Contractor shall perform all the statistical analysis as stated in the Method Performance/Validation section above and report data in an organized, clearly comprehensible format. Training. The Contractor shall provide an instrument training program that is coordinated with and timely to the equipment installation, sufficient to the size and scope of the facility s services and minimally equivalent to the terms and conditions for training defined in the Contractor s Federal Supply Schedule FSC Group 66, Part III, Cost-Per-Test Clinical Laboratory Analyzers contract. This shall include training on the operation of the system, data manipulation, and basic trouble shooting and repair. Thereafter, the Contractor shall provide training for minimally one operator per facility per year at the discretion of the Government for each model of instrumentation placed. Utilization of the training slots shall be mutually agreed upon between the VA and the Contractor. A training program that involves off-site travel shall include the cost of airfare, room and board for each participant. Equipment Preventative Maintenance/Repair Service - The Contractor shall be able to provide emergency equipment repair and preventative maintenance on all primary and back-up instrumentation and any incremental support equipment, e.g., water system, offered according to the following terms: The Contractor will provide access to a technical assistance center that is available 24 hours per day, 7 days per week with a maximum call back response of two hours. Equipment repair service call shall be provided during routine business hours which are typically 8a.m. to 430 p.m. Certain circumstances may dictate the need for repair service to be conducted outside routine business hours. The Contractor is required to maintain analyzers in working order (able to perform patient testing). The Contractor must be prepared to provide services outside of normal routine hours. Equipment repair response time shall be no more than 3 hours. Preventive maintenance will be performed according to published manufacturer operator s manual and within two weeks of the scheduled date. Reports of service shall be furnished to the Laboratory upon completion of each repair call. The report shall include, as a minimum, the following: Date and time notified, Date and time of arrival, Serial number, type, and model number of analyzer, Time spent for repair and proof of repair that includes documentation of a sample run of quality control verifying acceptable performance. Each notification of an emergency repair service call is treated as a new separate service call if both the primary and back-up analyzers are not functioning properly. Contractor is required to provide emergency service after core business hours and on weekends. Upgrades - The Contractor shall provide upgrades to both the equipment hardware and software in order to maintain the integrity of the system and the state-of-the-art technology at no additional charge to the Government. These shall be provided as they become commercially available and at the same time as they are being provided to commercial customers. This requirement only applies to system upgrades that enhance the model of equipment being offered, i.e., new version of software, correction of hardware defect, upgrade offered to commercial customers at no additional charge, upgrade to replace model of equipment no longer Contractor supported, etc. This does not refer to replacing the original piece of equipment provided under the BPA; however, it does refer to significant changes in the hardware operational capability. Ancillary support equipment - The Contractor shall provide, install and maintain through the life of the BPA, as indicated, any and all ancillary support equipment to fully operate the analyzer as defined in these specifications, e.g., cabinetry to support/house the analyzer (if necessary), water systems (including consumable polishers, filters, etc.), and universal interface equipment, etc. In addition, the Contractor shall include all ancillary components that are customarily sold or provided with the model of equipment proposed, e.g., starter kits, tables/stands, etc. Interface requirements Contractor will provide all hardware required for the connection, implementation, and operation of the interface to the universal interface and any incremental fee that is required each time an analyzer is added to the existing universal interface system. Contractor will provide any, and all necessary software support for ensuring successful interfacing is established. Specific requirements for the communication of the data stream will be unique to the analyzers system involved and dictated by the manufacturer itself. The Contractor will supply the information necessary to make the determination for type and amount of interfacing analyzers to be supplied. When the Government site has a universal box, the Contractor will be responsible for everything leading up to the box including any incremental fees required to add additional analyzers (ie. licenses, port/cards, cable, software, etc.) to the universal interfacing system. When the Government site does not have a universal interface, and one is needed to optimally interface the analyzer, the Contractor will be responsible for the acquisition of the universal interface box and everything else needed to connect to the VA computerized hospital information system. If there are any software upgrades in the instrument during its life, the Contractor is responsible for ensuring the interface can accommodate any changes in the data stream going to the VA computerized hospital information system. Interface capability for back-up analyzer. Commercial Offerings The Contractor shall provide any additional support material that is routinely provided to equivalent commercial customers and assists in regulatory compliance, e.g., Computer disc containing their procedure manual in CLSI format or an on-line procedure manual in the instrument software. Characterization of Waste The Contractor shall provide documentation that it has characterized the hazardous nature of all wastes produced by all equipment, devices, reagents, and discharges in accordance with the requirements of the Code of Federal Regulations Title 40 Protection of the Environment Part 261 et seq. and applicable state and local requirements. Documentation shall include a description of the characteristics of the hazardous waste produced as a byproduct of the instrument operations, Safety Data Sheets (SDS) meeting the requirements of the Occupational Safety and Health Administration (OSHA) and Environmental Protection Agency (EPA), the analytical process used to determine the hazardous nature and characteristics of the waste, and the analytical test results. Testing of hazardous waste is to be done in accordance with testing protocol specified for each individual waste, as described in the Code of Federal Regulations Title 40, to make a determination if the waste is a hazardous waste or otherwise regulated. The determination and description shall address the following: Waste toxicity (Reference 40 CFR §261.11 and 40 CFR §261.24) Waste ignitability (Reference 40 CFR §261.21) Waste corrosivity (Reference 40 CFR §261.22) Waste reactivity (Reference 40 CFR §261.23) Hazardous waste from non-specific sources (F-listed) (Reference 40 CFR §261.31) Discarded commercial products (acutely toxic or P-listed and toxic or U-listed) (Reference 40 CFR §261.33) Solid Waste (Reference 40 CFR §261.2) Exclusions (Reference 40 CFR §261.4) The Contractor will provide written instructions and training material to ensure VHA laboratory staff are trained as needed to properly operate devices with special emphasis to managing and disposing of hazardous waste in accordance with EPA and state requirements. Additionally, the training provided by the Contractor must fulfill Resource Conservation and Recovery Act (RCRA) requirements for training as applicable to devices. Contractor shall provide a description of all wastes the process or equipment may discharge so that the facility can determine whether the discharge meets Local Publicly Owned Treatment Works (POTW), State and Federal discharge requirements. At a minimum the characteristics of ignitability, corrosivity, reactivity and toxicity as defined in 40 CFR §261 must be determined and documented. Any mercury containing reagents must be identified in any concentrations. All test results shall be provided. All listed chemicals (F, U, K and P) found in 40 CFR §261 shall be provided in product information and their concentrations documented. For those materials with a positive hazardous waste determination, a mechanism for the laboratory to meet local discharge requirements (i.e., mercury, thimerosal and formaldehyde) must be developed and SDS sheets must be provided in advance for review. At a minimum, documentation shall include, but not be limited to the concentration/measures of the elements and parameters listed below and must be included with Contractor response: Barium (Total) Cadmium (Total) Chromium (Total) Copper (Total) Cyanide (Total) Lead (Total) Mercury (Total) Nickel (Total) Silver (Total) Zinc (Total) Arsenic (Total) Selenium (Total) Tin (Total) pH Flash point (to higher than 200 F) BOD; biochemical oxygen demand The documentation the Contractor provides will be used to work with the VAMC and the public and/or private organization (e.g., POTW) to determine whether or not the waste from each device can legally be disposed of via the sewerage system Implementation/transition timeframe - The implementation of the services/requirements described in this solicitation shall be completed no later than 60 days after the award of the BPA. This timeline is based on a reasonable attempt of the Contractor to complete all of the necessary implementation requirements within the stated timeframe. Contractor shall not be penalized for implementation timelines that extend beyond the 60-day timeframe if the extension is through no fault of the Contractor and is a result of delays due to the Government. Upon award of a BPA, the transition period for the awarded BPA to have all equipment and peripherals installed and operational shall be from date of award through 120 days. During this same period all initial training of VA personnel in the operation and maintenance of said award shall also be completed. Contractor shall provide with its quotation an implementation plan for installation of new equipment. Contractor s submitted plan shall not exceed 120 days for the transition of all services under the awarded BPA including installation and training of personnel, transition of all testing materials, reagents, and supplies, etc., performance of all correlations and validations. Failure of the Contractor to conform to the transition period shall be considered as sufficient cause to terminate BPA for cause under the Termination for Cause clause of the BPA. At the end of 120 days from award of the BPA, the awarded Contractor shall have full and sole responsibility for services under the awarded BPA. Standard and Quality of Performance - This paragraph establishes a standard of quality perf...

More opportunities from Department Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)

Same awarding agency

NAICS: 325412
New
Federal
6505--INTENT TO SOLE SOURCE Radiopharm - Lutathera & Pluvicto - Lebanon VAMC
Solicitation # 36C24427Q0045
The Department of Veterans Affairs, Network Contracting Office 4, intends to establish a firm-fixed-price contract for the procurement and delivery of name-brand Lutathera and Pluvicto radiopharmaceuticals for the Lebanon VA Medical Center. The scope of work includes the distribution, transportation, and inventory management of 8 doses of Lutathera and 48 doses of Pluvicto, both at 200mCi intravenous injection. The proposed period of performance is from January 1, 2027, to December 31, 2027. The government intends to sole source this requirement to Novartis Pharmaceuticals Corporation under the Revolutionary FAR Overhaul (RFO) for FAR 8.4 and GSAM/R 538.71, in accordance with Executive Order 14275. The contractor must be licensed by the Nuclear Regulatory Commission and comply with FDA, OSHA, and DOT regulations, including the use of lead-shielded containers and specific labeling requirements such as bar-coding for dose tracking. Deliveries must be made F.O.B. Destination to the Lebanon VA Medical Center, with routine shipments arriving at least one hour before calibration time. Preference will be given to contractors utilizing non-High Enriched Uranium sources. This notice is for planning purposes, and interested vendors must submit a one-page capability statement, including their SAM UEI number and socioeconomic category, to the Contracting Specialist by November 3, 2026, at 14:00 PM EST. The procurement falls under NAICS code 325412 with an SBA size standard of 1,300 employees.
Pharmaceutical Preparation Manufacturing

POSTED

about 12 hours ago

DEADLINE

in 5 days
View Details
NAICS: 339112
New
Federal
6515--Full Body Phototherapy
Solicitation # 36C24427Q0046
The Department of Veterans Affairs is conducting market research through a Sources Sought Notice to identify qualified sources for the one-time acquisition of one full body clinical phototherapy cabinet for the Wilmington VA Medical Center in Delaware. The equipment is intended for treating dermatologic conditions such as psoriasis, vitiligo, and eczema. Key technical requirements include a minimum operational lifespan of five years, a minimum one-year manufacturer service warranty, and the ability to support narrowband UVB, UVA, and combination therapies. The unit must feature forty-eight high-intensity six-foot ultraviolet lamps, an integrated dosimetry system, a touchscreen interface, and a temperature-management system with patient-controlled cooling. Additionally, the cabinet must be wheelchair accessible, include ultraviolet-transmitting acrylic shields, and maintain treatment history locally without requiring connection to the VA network. Vendors must also offer yearly maintenance services as part of their commercial catalog. This notice is for market research purposes only and does not constitute a binding offer or a formal solicitation. Interested respondents must submit their company details, SAM UEI number, business size classification, and any existing government contract vehicles to the designated point of contact by 6:00 am ET on November 10, 2026. The acquisition falls under NAICS code 339112 with a size standard of 1,000 employees. Small businesses must demonstrate compliance with the nonmanufacturer rule and provide a letter of authorization from the original equipment manufacturer if acting as a distributor. Large businesses are required to disclose any designated distributors. Responses should include capability materials such as brochures or hyperlinks to help the government determine the technical capabilities of the proposed equipment.
Surgical and Medical Instrument Manufacturing

POSTED

about 12 hours ago

DEADLINE

in 11 days
View Details
NAICS: 561730
New
Federal
S218--Snow Removal Services Wilmington VAMC
Solicitation # 36C24427Q0O12
Solicitation 36C24427Q0012 is a combined synopsis and request for quote for snow removal and deicing services at the Wilmington VAMC in Delaware. This is a five-year Indefinite Delivery/Indefinite Quantity (IDIQ) contract with an anticipated period of performance from December 1, 2026, through November 30, 2031. The contract has a minimum guarantee of 5,000 dollars and an estimated maximum value of 500,000 dollars, with funds obligated via individual task orders. The procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 561730. The scope of work includes clearing all levels of a multi-level parking garage, stairwells, entrances, and exposed ramps, with a requirement that all areas be cleared by 6:00 AM EST following overnight snowfall. Specific chemical restrictions are in place, prohibiting rock salt in the garage and requiring the use of garage-friendly chemicals such as sodium acetate, potassium acetate, or calcium magnesium acetate. The contractor must provide an on-site supervisor for every operation and ensure personnel wear OSHA-required PPE and high-visibility vests. Performance will be evaluated based on a Quality Assurance Surveillance Plan, and the award will be based on a comparative evaluation of technical capability and past performance, as well as price. Offerors must be registered in the System for Award Management and submit their quotes via email to the designated contract specialist. Submissions must include a technical document not exceeding 20 pages, firm fixed pricing for all line items, and three examples of past performance for similarly scoped work. Invoices are to be submitted electronically in arrears upon job completion and are due within 30 days. Compliance with applicable wage and hour laws and limitations on subcontracting are mandatory for the prime contractor.
Landscaping Services

POSTED

3 days ago

DEADLINE

in 4 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS