High-Pressure Desuperheater Spray Liner Replacement

Closed
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract involves the fabrication, removal, and installation of high-pressure desuperheater spray liners fabricated from P91 and P22 steel, requiring strict adherence to ASME standards for welding, non-destructive examination, and post-weld heat treatment. The work is critical to maintaining the integrity and operational safety of high-pressure steam systems, and all materials and processes must meet the rigorous metallurgical and mechanical specifications associated with P91 and P22 alloys. Skilled personnel with proven experience in high-temperature, high-pressure environments are necessary to ensure compliance with code requirements and to guarantee long-term performance under extreme operating conditions. The solicitation was posted on January 8, 2025, with a response deadline of January 29, 2025, and is classified as a subcontract under NAICS code 332999 for other fabricated metal product manufacturing. The contracting entity is Lakeland Production based in Florida, though specific location details for performance or contact information are not provided. The work is expected to occur at an undisclosed facility under the agency’s operational jurisdiction, and interested parties must submit proposals prior to the deadline without details regarding set-aside status or eligibility requirements. The project emphasizes technical precision and regulatory compliance over broad procurement flexibility, targeting specialized subcontractors with documented expertise in power plant component fabrication and repair.

General Info

Fabricate, remove, install P91/P22 desuperheater liners per ASME standards for high-pressure steam systems.

Documents

This scope was carved out of 2025-RFP-002.

The full solicitation package (15 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Unit 5 Spring 2025 Outage Contractor Services

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyFlorida → Lakeland Production
ContactsNo contacts available
OfficeN/A
Organization / AgencyFlorida → Lakeland Production
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Fabrication, removal, and installation of high-pressure desuperheater spray liners using P91/P22 steel, including ASME-compliant welding, NDE, and post-weld heat treatment.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS