Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on April 10, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

High Temperature Heaters

Closed
W15QKN-24-X-0ZT2Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

333912 - Air and Gas Compressor Manufacturing

Place of Performance

NJ

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W4MK Ccdc Armaments Center
Contacts1 person available
OfficePICATINNY ARSENAL, NJ, 07806-5000, USA
Office AddressPICATINNY ARSENAL, NJ, 07806-5000, USA

Full Description

Show more
This is a Sources Sought (SS) issued by the Army Combat Capabilities Development Command (DEVCOM), Armaments Center (AC), Munitions Engineering & Technology Center (METC) and Aeroballistics Division. This effort is for information to pan a potential acquisition strategy and contract for a wind tunnel heater. The effort supports a wind tunnel facility in building 266. Responders to this SS notice are asked to provide statements with the following information related to meeting requirements: A narrative explaining the company's background, and past/current experience relevant to furnishing and installing wind tunnel heaters. The target temperature range required would be between 500'F for a Mach 5.0 condition to 800'F for a Mach 6.5 condition. If temperatures can exceed 800F, that would provide margin for the system to accommodate future higher velocity testing. For the inlet into the heater, this system is not expected to run in less-than-ideal weather conditions. The minimum temperature of air into the heater is about 0'C or 32'F. The pipe diameter for the current heater is 10 inches, and up to 100ft of piping will separate the heater from conditions in the wind tunnel (point of usage). The available voltage for this system is 480V3-Phase. Once the details are confirmed on the process conditions above, we can give you the rough KW requirement which will determine the overall amperage requirement. Your firm will then be able to verify that amount of amperage is available on site. This is a SS for market research purposes. Any response to this SS is at the sole-discretion of the contractor. No remittance payment will be made for any information sent in response to this SS. Information submitted in response to this SS may be used for procurement planning purposes. The information received by the Government will not be released to third parties. Interested parties should be cognizant of the - beta.sam.gov portal, and of the acquisition process to ensure responsiveness to any opportunities related to issuance of a formal solicitation. The website for Beta. Sam is as follows - https://sam.gov/. Currently, a formal solicitation is not definitive. All responses to this SS shall be unclassified. Request that all responses included the following information: Filly Company Name (Legal Entity): Cage Code: Website (if applicable): Contact Information: Business Size Status.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS