Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

Install Electric

Active
WO17835372Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Department of Defense, specifically the 42 Cons Cc agency, is seeking a contractor for solicitation WO17835372 to install electrical systems in a storage area located in Building 1455. The selected contractor must provide all required equipment, labor, supervision, and materials to complete the project in Montgomery, Alabama. This opportunity is designated as a total small business set aside under NAICS code 238210. The solicitation was posted on September 1, 2026, with a response deadline of September 15, 2026. Primary coordination for this project is managed by Jordan Johnson at Maxwell AFB.

General Info

DoD seeks small business contractor for electrical installation at Building 1455, Montgomery, Alabama.

Agency

Department Of Defense → FA3300 42 Cons CcView Agency

NAICS

238210 - Electrical Contractors and Other Wiring Installation ContractorsView NAICS

Place of Performance

Montgomery, AL, 36112, USA

Set-Aside

SBA

Documents

(3)

WO17835372 Combined Synopsis/Solicitation for Install Electric

PDFrfq

WO17835372 Provisions and Clauses Incorporated by Reference

PDFcontract-document

SOW 17835372 – Installation of Electrical Outlets and Circuits, Building 1455A

PDFsow

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseCombined Synopsis
Posted

Combined Synopsis

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA3300 42 Cons Cc
Contacts2 people available
OfficeMAXWELL AFB, AL, 36112-6334, USA
Organization / Agency
Department Of Defense → FA3300 42 Cons Cc
View Agency Profile
Office AddressMAXWELL AFB, AL, 36112-6334, USA

Full Description

Show more

The Contractor shall furnish all necessary equipment, labor, supervision and materials to install electric in a storage area in Building 1455.  

Similar Contracts

Same NAICS industry code

NAICS: 238210
New
MAIN GROUNDING ELECTRODE
Solicitation # WL-26-006
Adams and Associates, operating the Woodland Job Corps Center for the U.S. Department of Labor, is soliciting proposals from licensed electrical contractors to inspect and repair main grounding electrode systems in Laurel, Maryland. The scope of work involves correcting improperly sized grounding electrode conductors in the Aspen Dorm, Vocational Building, Willow Hall, Holly Dorm, Maple Dorm, and Oak Dorm, as well as installing a new main grounding electrode in the Administration Building. All work must comply with NEC 2023, 250 standards, EPA, and OSHA regulations. Key technical requirements include the installation of #2/0 AWG conductors, 16x2 inch ground bars, and 8-foot ground rods with specific separation and conduit routing. The solicitation is a set-aside for various small business categories, including SDB, WOSB, HUBZone, and SDVOSB. Proposals must be submitted by September 3, 2026, and include a lump sum cost with a detailed breakdown, a timeline for substantial completion, and proof of a valid Maryland contractor's license. Award will be based on best value, evaluated across price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Selected contractors must provide a sequenced construction schedule within 10 days of the Notice to Proceed and start work within 14 days. The contract includes a one-year workmanship guarantee and net 30 payment terms. Required documentation for final acceptance includes a completed SF 1413, release of liens, and certified payroll records.
Adams & Associates\ Woodland Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in 1 day
View Details
NAICS: 238210
New
PANELBOARDS
Solicitation # WL – 26 -0004
Adams and Associates is soliciting a single lump sum subcontract for electrical panelboard repairs and labeling at the Woodland Job Corps Center in Laurel, Maryland. The primary objective is to correct electrical deficiencies by providing complete, non-handwritten circuit directories for panelboards in the basement mechanical room, first floor food preparation area, dishwasher room, and electrical room. Specific technical requirements include labeling the fire alarm control panel power supply breaker with a UL listed red mark and replacing missing panelboard covers, all in strict accordance with NEC 2023 standards. The project requires a one-year guarantee on workmanship and manufacturer products, with payment terms set at Net 30. Eligible offerors must be small businesses and provide proof of a valid Maryland contractor's license, a W9, and a completed vendor questionnaire. Proposals must include a detailed cost breakdown for labor, materials, and equipment, a timeline for substantial completion, and a 90-day bid guarantee. A mandatory site visit and pre-bid conference are required for eligibility. Award will be based on best value rather than the lowest price. The selected contractor must adhere to EPA and OSHA regulations, comply with Service Contract Labor Standards wage determinations, and maintain specific automobile and workers compensation insurance naming Adams and Associates, Inc. as an additional insured. Work must commence within 14 days of the Notice to Proceed.
Adams & Associates\ Woodland Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in 1 day
View Details
NAICS: 238210
New
Wind River Job Corps: LAWN EQUIPMENT STORAGE ROOM VENTILATION
Solicitation # wind-river-job-corps-lawn-equipment-storage-room-ventilation
Arbor E & T, LLC dba Equus Workforce Solutions is seeking bids for a subcontracting opportunity to remediate a life safety deficiency at the Wind River Job Corps Center in Riverton, Wyoming. The project involves installing mechanical ventilation in a lawn equipment storage room to mitigate dangerous fuel vapor accumulation. The scope of work includes creating an 18-inch by 18-inch rough opening in an exterior concrete block wall, installing one wall-mounted explosion-proof exhaust fan capable of approximately 600 CFM mounted 15 feet above the floor, and installing two 18-inch by 24-inch door-mounted ventilation louvers. The contractor must also provide approximately 90 linear feet of conduit and wiring for a 208 volt, 1 phase, 1/3 HP motor designed for continuous operation. All electrical work must adhere to the National Electrical Code, and contractors must follow Lockout/Tagout procedures and use standard commercial PPE. This is a fee-for-service solicitation under NAICS code 238210, with a size standard of 19 million. The award will be based on best value as determined by Equus. Bidders must submit a price quote on the provided bid sheet, a vendor self-certification form, and signed terms and conditions by 2:00 PM MST on September 2, 2026. The contract is subject to the Service Contract Act, requiring compliance with Wage Determination No. 2015-5407 for Wyoming. Key federal regulations are incorporated, including FAR clauses regarding the Combating Trafficking in Persons, Small Business Program representations, and insurance for work on government installations. Final acceptance requires the storage room to be swept clean and surfaces wiped down to return the space to a fully operational state.
EQUUS Workforce Solutions operator of the Wind River Job Corps

POSTED

about 4 hours ago

DEADLINE

in about 1 hour
View Details

More opportunities from Department Of Defense → FA3300 42 Cons Cc

Same awarding agency

NAICS: 238910
New
Federal
Amendment - 003 - FY26 OTS Rappel Tower Demolition Service
Solicitation # FA3300FY26OTS091462
The Department of Defense, through the 42nd Contracting Squadron at Maxwell AFB, is soliciting firm-fixed price quotations for the professional demolition and removal of the 60-foot wooden Blue Thunder Rappel Tower. The scope of work includes the systematic demolition of the structure, removal of all guy wires and ground anchors, and the excavation of sub-surface supports and footings to a minimum of 4 inches below final grade. The contractor is responsible for the legal off-base disposal of all debris at an approved construction and demolition landfill and must restore the site by backfilling excavated areas with compacted fill dirt and replenishing the central sand pit with clean sand. This procurement is a total small business set-aside with a performance period of 30 days. Award will be granted to the lowest-priced contractor that meets the minimum technical and security requirements, including the ability to perform unclassified demolition services. Contractors must comply with strict installation access protocols, requiring a REAL ID or valid US Passport for personnel and vehicle insurance for drivers. Safety requirements include the establishment of daily exclusion zones and foreign object debris sweeps. Payment shall be processed electronically via the Wide Area WorkFlow system. The final response deadline for quotes is September 10, 2026, at 5:00 PM EDT.
Site Preparation Contractors

POSTED

2 days ago

DEADLINE

in 8 days
View Details
NAICS: 238350
New
Federal
Amendment 0001- Conex Refurbishment, Officer Training School (OTS), Maxwell AFB
Solicitation # FA330026P0819
This contract is a small business set-aside solicitation for the comprehensive restoration and repair of 27 Conex containers at the Vigilant Warrior training site in Titus, Alabama. The primary objective is to eliminate safety hazards caused by severe wood deterioration and restore the environmental integrity of the units to support the annual training of over 5,000 cadets. The scope of work includes replacing deteriorated wood framing and flooring in compliance with military construction standard UFC 1-200-01, restoring window and door frames for weatherproof sealing, and ensuring all units are sealed against water, wind, and pests. All structural modifications must be certified by a licensed structural engineer, and all replacement materials must be brand new. The project requires a detailed construction phasing plan to ensure at least 70 percent of the containers remain operational, with no more than 12 units out of service at any given time. The contractor must implement a Quality Control Program with inspection hold points at 25, 50, and 75 percent completion for each container and provide monthly progress reports. Warranty requirements include a minimum 15-year service life for materials and a 10-year manufacturer warranty on primary structural components, with a 48-hour response time for issues affecting training operations. Award will be granted to the lowest price offeror that achieves acceptable ratings for both technical capability and past performance.
Finish Carpentry Contractors

POSTED

2 days ago

DEADLINE

in 6 days