INSTALL NCC HVAC B602

Closed
W50S7526QA019Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The California Air National Guard’s 146th Airlift Wing at Channel Islands ANG Station in Port Hueneme, California, is seeking qualified small businesses to install a new NCC HVAC/CRAC system in Building 602, with a planned contract award under a firm-fixed price structure and a completion deadline of March 31, 2027. This requirement is set to be 100% reserved for small businesses as defined by the NAICS code 333415, with a size standard of 1,200 employees, and will follow simplified acquisition procedures under FAR 12.201-1. The contractor must provide all labor, equipment, materials, supervision, and quality control necessary to remove the existing rooftop condensing unit and indoor CRAC system, properly dispose of refrigerants and equipment, and install a new Leibert VS070AZA1E0NQVO split system CRAC unit with up to 30-ton variable capacity cooling, upflow configuration, glycol economizer support, component redundancy, and UL-listed components. The associated outdoor condensing unit, model MCM080E5AD2DT5, must include microchannel coils, EC fans, coastal corrosion resistance, and Quietline Mode operation. All work must comply with manufacturer specifications, TIA-942 and ASHRAE TC 9.9 standards, and include new refrigerant lines, drain piping, duct plenums, electrical reconnections, and integrated leak detection and fault alert systems. The contractor is responsible for all waste removal, environmental compliance, hazardous material documentation, and restoration of any damaged government property. Installation must be performed by licensed professionals after a mandatory site visit, with all equipment new, defect-free, and properly labeled. Interest in this pre-solicitation notice must be expressed by submitting firm contact details and SAM UEI number via email to Ricardo Macias and William Tucker no later than 4:30 PM PDT on June 16, 2026. The official solicitation, numbered W50S7526QA019, will be issued via SAM.gov and will include the definitive due date for quotes, which must be submitted no fewer than ten days after publication. This announcement serves only as a planning tool and is not a binding procurement action; no formal bid documents are available at this time. All vendors must have an active SAM registration to be eligible for

General Info

California ANG seeks small business for HVAC/CRAC installation, completion by March 2027, firm-fixed-price.

Agency

Department Of Defense → W7MX Uspfo Activity Caang 146View Agency

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment ManufacturingView NAICS

Place of Performance

Port Hueneme, CA, 93041, USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W7MX Uspfo Activity Caang 146
Contacts2 people available
OfficePORT HUENEME, CA, 93041-4011, USA
Organization / Agency
Department Of Defense → W7MX Uspfo Activity Caang 146
View Agency Profile
Office AddressPORT HUENEME, CA, 93041-4011, USA
Contacts
Ricardo Macias
William Tucker

Full Description

Show more

This announcement is for information and planning purposes.  It is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. 


The California Air National Guard, 146th Airlift Wing (146th AW) Channel Islands ANG Station, Port Hueneme has a requirement entitled: INSTALL NCC HVAC B602


The 146th AW intends to solicit quotes from at least three (3) interested sources in accordance with RFO FAR 12.201-1 Simplified procedures.  This is expected to be 100% set aside for a Small Business competition after approvals are completed and is intended to result in award of one (1) firm-fixed price contract with an expected contract delivery/contract completion date of 31 March 2027.


The general salient characteristics of the requirement include but are not limited to: The Contractor shall provide all personnel, equipment, tools, materials, supervision, and quality control necessary to install a new NCC HVAC/CRAC unit in Building 602 on Channel Islands Air National Guard Station, Port Hueneme, CA 93041.


Attend a Site-Visit to assess scope of work prior to quoting on this requirement. All work under this division shall be executed in a thorough professional manner by competent and experienced workmen licensed to perform the work specified. All work shall be installed in strict conformance with manufacturer’s requirements and recommendations. Equipment and materials shall be installed in a neat and professional manner and shall be aligned, leveled, and adjusted for satisfactory operation. Material and equipment shall be new, shall be of the best quality and design, shall be current model of the manufacturer, shall be free from defects and imperfections and shall have markings or a nameplate identifying the manufacturer and providing sufficient reference to establish quality, size, and capacity. Material and equipment of the same type shall be made by the same manufacturer and be Underwriters Laboratory (UL) Listed. 


 Provide the following supply with install:


5.2.1    Secure electrical power at source by lock-out/tag-out for the rooftop condensing unit and the indoor CRAC unit in the computer room.


5.2.2    Recover all refrigerant from the existing system and properly dispose of at exchange facility.


5.2.3    Disconnect, demo and remove all copper refrigerant lines, rooftop condensing unit and indoor CRAC unit from site and properly dispose of.


5.2.4    Furnish and install (1) new Split System DX CRAC Unit (Leibert Model#VS070AZA1E0NQVO or equivalent) that includes Microprocessor with Touchscreen Controller, Factory Disconnect, Dual Scroll Compressors, Steel Frame, R454B Refrigerant, Zone Leak Detection, 460V 3PH.


5.2.4.1 Up to 30-ton cooling with variable capacity control


5.2.4.2 Upflow configuration


5.2.4.3 Supports glycol economizer coils


5.2.4.4 Component redundancy


5.2.4.5 AHRI certified


5.2.5    Install new roof-mounted Condensing Unit (Leibert M#MCM080E5AD2DT5 or equivalent) with Factory Disconnect, Coastal Coating on the condenser coils, and Microchannel Coils, and set on the roof on the existing steel framing at the existing location.


5.2.5.1 Type & Design: Air cooled, microchannel coil condenser with Premium Efficiency Control / EC Fan for reduced energy use


5.2.5.2 Sound Level: Operates at 2.5–5.5 dBA lower than alternative condensers


5.2.5.3 Fan Technology: Electrically commutated (EC) fans


5.2.5.4 Compatibility: Works with R 410A and R 407C refrigerants


5.2.5.5 Quietline Mode: Automatically adjusts fan speeds


5.2.5.6 Corrosion Resistance: Constructed for long service life in demanding environments


5.2.6    Make all necessary frame modification to fit to new unit configuration.


5.2.7    Furnish and install all new properly sized copper refrigerant lines and connect to both indoor and outdoor units with all required accessories, insulate with rubber pipe insulation and aluminum cladding for exterior as needed.


5.2.8    Reconnect existing line voltage electrical supply, required fuses, required 1-1/2” conduit and fittings to connect existing power to both indoor CRAC unit and rooftop Condenser.


5.2.9 Install all new ¾” Type L copper condensate drain lines from the new unit, add ¾”copper pipe and any required fittings as needed to run to existing drain and reconnect to existing copper drain.


5.2.10 Install new Factory Provided Metal Supply Duct Plenum box with supply grills to fit the new indoor unit.


5.2.11 New CRAC unit is provided with new smoke duct detector on new unit. (Connecting to existing fire alarm panel or interface is excluded)


5.2.12 Start, check, test and program all newly installed equipment, PVT testing, in-house commissioning, training and verify operation.


5.3        The new equipment shall adhere to TIA 942’s temperature and humidity standard and ASHRAE’s TC 9.9 critical data center thermal guide.


5.4        Incorporate an alerting system that can communicate faults, outages, extreme temperatures, and other critical information to prevent catastrophic failure.


5.5 Remove any waste or excess material resulting from the performance of work. The Contractor shall remove and dispose waste or material at a proper disposal site outside of Channel Islands Air National Guard Station. Any disposal, discharge, deposit, dumping, spilling, leaking, or placing of any materials, wastes, affluents, trash, garbage, oil, grease, paint, chemicals, etc. shall be notified and coordinated with the Installation Environmental Office and/or COR. Dumping of any waste or material in an unauthorized location is prohibited and the Contractor shall be responsible for the removal and/or restoration of the area to the condition of the adjacent undisturbed site.


5.6 Maintain a copy of the Environmental Protection Agency or State Registered Labels, plus Material Data Sheets for all paints, primers, solvents, inhibitors, or solutions used in connection with this contract; Material Data Sheets are also required for all hazardous materials defined in Federal Standard 313c.  Copies of these documents shall be provided to the COR prior to the start of any work.


5.7 Any damage to existing Government property as a result of the work accomplished in this Contract shall be repaired and/or replaced to match pre-existing conditions at the Contractor’s expense.


The North American Industry Classification System (NAICS) code for this project is 333415 Air Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing with a small business size standard of 1,200 employees.


This Sources Sought/Pre-solicitation Notice is not a Request for Quote (RFQ), Request for Proposal (RFP), or an Invitation for Bid (IFB).


This Notice is published for this proposed action in accordance with RFO FAR 5.101(a). The 146 Wing will provide more information in the official solicitation.  Quotes will be due no less than 10 days from the date the solicitation is issued.  The definitive due date and time will be stated in the solicitation and any associated amendments that may be issued.


No CDs or hard copies of the solicitation will be available.  Interested vendors are responsible for checking https://SAM.gov for any update(s) to this Notice.  The Government is not responsible for any loss of Internet connectivity or for any vendor’s inability to access any documents posted on the above-mentioned website.


To conduct business with the Department of War, a Contractor must provide registration information to the System for Award Management (SAM).  All offerors must be actively registered at SAM prior to receiving an award.  Registration instructions may be obtained, and online registration may be accomplished at https://SAM.gov.


This announcement is for information and planning purposes.  If your firm is interested in this requirement and would like to receive the RFQ when distributed, email your interest and firm’s contact information with SAM UEI# to ricardo.macias.3@us.af.mil and william.tucker.32@us.af.mil on or before 4:30 PM PDT on 16 June 2026.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS