This Combined Synopsis/Solicitation opportunity from Department Of Homeland Security was posted on April 3, 2013. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Install Remote Monitoring Station CCTV

Closed
21-13-293PFP126Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency is soliciting proposals under RFP-VC-26-010 for professional transformer oil testing services to enhance the reliability, safety, and maintainability of its transformers. The scope of work is divided into three primary areas: conducting condition assessments through visual and infrared thermographic inspections, installing standardized external oil sampling devices to improve safety, and performing oil testing analysis. Additionally, the selected contractor will evaluate nitrogen blanket systems to ensure positive pressure and prevent oxidation, provide on-site training for up to 20 agency staff members, and develop comprehensive standard operating procedures. All work must adhere to NETA MTS, IEEE, NFPA 70E, and ASTM D923 standards, with infrared inspections performed by technicians certified to ASNT Level 1 or higher. This is a fixed-price contract with a not-to-exceed ceiling and an initial term that may be extended for several one-year periods at the agency's discretion. The agency intends to make a single award based on the offeror's past performance, staffing plan, methodology, and cost-effectiveness. Qualified bidders must have completed at least two similar projects within the last five years, including one for a utility or industrial facility. Proposals must be submitted electronically via PlanetBids by December 23, 2026, and must include a detailed company profile, project approach, and various required certifications, including a Non-Collusion Statement and Workers' Compensation Certificate. Payment will be processed electronically via ACH within 30 days of invoice approval.
Inland Empire Utilities Agency

POSTED

about 5 hours ago

DEADLINE

in about 2 months
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management and Training Corporation is soliciting bids for a fixed-price, single lump sum contract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project involves engaging a qualified electrical contractor to inspect, test, repair, and certify emergency lighting systems in accordance with NFPA 101 (2024 Edition), NFPA 70, and OSHA regulations. The estimated contract value ranges between $25,000 and $100,000, with a required performance period of 30 business days following the written Notice to Proceed. Award will be based on overall best value, and mandatory requirements for consideration include a physical site visit and a bid bond guarantee of 20% for bids equal to or exceeding $25,000. The contractor must adhere to strict labor and safety standards, including the Davis-Bacon Act, Construction Wage Rate Requirements, and FAR 52.222-4 regarding overtime compensation. Performance and payment bonds are required for awards of $25,000 or more from a surety company with at least an A- rating. Bidders must submit a signed lump sum bid form and a detailed cost breakout on company letterhead to Sandra Clore by December 1, 2026. Additionally, the awarded contractor must provide a 12-digit Unique Entity ID (UEI) and comply with various federal regulations, including FFATA reporting for contracts over $40,000 and debarment disclosures for first-tier subcontracts exceeding $45,000.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 5 hours ago

DEADLINE

in about 1 month

General Info

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Place of Performance

453 Admiral Craik Drive, GRAND ISLE, LA, 70358, USA

Set-Aside

NONE

Documents

1

SOW_Grand_Isle_-_Remote_Monitoring_Station.doc

DOC

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → Base New ORLEANS(00029)
Contacts2 people available
OfficeNEW ORLEANS, LA, 70117, USA
Office AddressNEW ORLEANS, LA, 70117, USA
Contacts
Adam C. PaulinMK1
James W. FergusonStorekeeper

Full Description

Show more
We are looking to install a Remote Monitoring Station in OOD Berthing as part of an existing CCTV system at United States Coast Guard Station Grand Isle, Louisiana. The remote monitoring station will be incorporated into an existing CCTV system as a standalone to view engaged areas. The monitoring station will include 360 view of the 26 acre base; this is to include, but not limited to, full coverage of all parking areas, entire fence line, entrance ways and pool in accordance with the attached scope of work. 2. Scope (This can be found in the attached scope of work pages 2 & 3) 2.1. Install Remote Monitoring Station in Night Watch Room as part an existing CCTV system at United States Coast Guard Station Grand Isle, Louisiana. The remote monitoring station will be incorporated into an existing CCTV system as a standalone to view engaged areas. The monitoring station will include 360 view of the 26 acre base; this is to include, but not limited to, full coverage of all parking areas, entire fence line, entrance ways and pool. The placement location of the monitoring station shall be determined by the COR or command leadership personnel. 2.2. Monitor must be PELCO brand equivalent or better with IR high resolution and include installation to wall by brackets with tilt for monitors. The installation will include a Hewlett Packard (HP) Desktop with 8 GB Memory and 1 TB Hard Drive brand equivalent or better with graphic card, mouse and keyboard. Additionally, the installation will include network switch, wire, conduit and mounting materials. Moreover, training on how to operate the system must be included. 2.3. Previously installed equipment and software shall be utilized whenever possible except when: outdated, unserviceable, incompatible, or do not meet the minimum specifications outlined below. 2.4. Contractor shall assume a 32 month maintenance agreement immediately upon starting work on all new CCTV equipment as well as all existing CCTV equipment and also to include at least a yearly site visit for system maintenance and a 24-hour casualty response for system repair. All labor and parts shall be provided under the agreement. 2.5. Contractor shall perform all programming requirements for a completely integrated system. 2.6. Option should be available to allow system to tie into a 24 hours monitoring (i.e. Sector) for units without live 24 hour watch standing. 2.7. Equipment requirements: Hardware: - Mounting hardware shall be marine grade 302 stainless steel or better. - Conduit shall meet NEC requirement for exterior and interior use. - Fitting shall be water tight. - Junction boxes shall meet NEMA type 4 standards. Monitor: - LCD Monitor (Pelco brand or equivalent or better) Computer: - Desktop (Hewlett Packard brand equivalent brand or better) 2.8. System Testing and Commissioning: The contractor is responsible for all system testing. The contractor shall test all installed equipment before any tests are scheduled with Coast Guard personnel. The contractor is also responsible for scheduling the performance verification test (PVT) with designated U.S. Coast Guard government security representative (DCMS 3411, U. S. Coast Guard Headquarters, Washington, DC). The PVT shall ensure that all installed equipment is working according to specifications and ready for operation. If you would like to make a site visit please contact MK1 Adam Paulin at (504) 382-4390. If MK1 Adam Paulin cannot be reached please contact SK1 James Ferguson at (504) 382-4595. Site Visit dates and times are as follows: Thursday April 4th 7:00AM to 3:00PM Friday April 5th 7:00AM to 11:00AM Monday April 8th 8:30AM to 3:00PM Tuesday April 9th 8:30AM to 3:00PM Wednesday April 10th 7:00AM to 3:00PM Thursday April 11th 8:30AM to 3:00PM Friday April 12th 7:00AM to 11:00AM *****Please send quotes to SK1 James W. Ferguson either by e-mail or fax. *****

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS