Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity was posted on September 4, 2019. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Instruments & Laboratory Equipment / Leica Confocal Microscope

Awarded
NIAID-NOI-19-1975972Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Agency

N/A

Contract Value

$513,045.98

NAICS

333314 - Optical Instrument and Lens Manufacturing

Place of Performance

National Institutes of Health, NIAID, BETHESDA, MD, 20892, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Presolicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Tonia L AlexanderContract Specialist

Full Description

Show more
The National Institute of Allergy and Infectious Diseases (NIAID), intends to negotiate with Leica Microsystems Inc., 1700 Leider Lane, Buffalo Grove, Illinois 60089 on an other than full and open competition basis to procure one (1) Leica TCS SP8 X White Light Laser Confocal Microscope and a DFC3000 G Kit Confocal Camera system including: DMi8 CS Bino, Closed Loop Focus with AFC, Turret cooling for DMi8, Spill protection for DMi8, Optical Outfit + motorized ICT, Sola-SMII 365nm, Transmitted Light Brightfield Detector, Manual 3-plate stage, Scan Optics module HIVIS with rotation, FOV scanner SP8, X1 Port Emission Access, Two HyDs SMD, Laser 405 nm AOTF Flexible, Laser Kit WLL2 with cw VIS lines, Falcon FILM with WLL+PQ, SMD Excitation: 440 pulsed, Confocal Super-Resolution LAS X LIGHTNING Expert, Expert CUDA Workstation, 115V. See the attached list of line item descriptions, part numbers, and quantity. There will be a trade-in of a 14-year-old Leica SP5 Confocal Microscope, serial #5100000844. This acquisition will be processed under FAR Part 12 - Acquisition for Commercial Items an award will be made pursuant to the authority in FAR Part 13.501(a)(1). Only one award will be made as a result of this solicitation. This will be awarded as a firm-fixed price type of contract. Delivery to Bethesda, Maryland 20892 approximately 120 days after receipt and acceptance of award. The Research Technologies Branch (RTB) has a requirement for a Leica TCS SP8 X White Light Laser Confocal Microscope and a DFC3000 G Kit Confocal Camera. The main objective is the replacement of a 14-year-old Leica SP5 Confocal Microscope. This new instrument has a range of compatibilities not present in the current SP5 Confocal Microscope. Among the capabilities is the collection of fluorescence lifetime imaging (FLIM), which is the standard for analyzing colocalization and interaction of proteins. With dual channel FLIM, one channel can serve as a reference, and the other to monitor real time changes in the lifetime of the donor molecule. The instrument is equipped with a temperature-controlled incubator around the microscope to facilitate live cell experiments. There are four (4) HyD detectors, which are an order of magnitude more sensitive than the existing photomultiplier tube (PMT) detectors. The system will have the LAS X software, which allows for automated collection of tiled images. Additionally, a new confocal digital high sensitivity monochrome camera with passive cooling architecture is included to assure optimum results with the new instrument. These new capabilities will allow investigators to undertake studies of protein interactions that cannot be done now. Leica Microsystems Inc., is the only vendor to provide the Leica TCS SP8 X White Light Laser Confocal Microscope that is compatible with the aging SP5. There will be a trade-in of the SP5 Confocal Microscope, with the components of White Light Laser, XY Scanning Stage, DIC Prisms C, D, E, K3, K6, K10, HyD Detector, PMT Detector, Computer Table, Air Table, and a Compressor, that will be configured to the SP8. The statutory authority for this sole source requirement is 41 U.S.C. 253 (c) (1) as implemented by FAR 6.302-1 only one source available, no substitutions possible. THIS IS NOT A SOLICITATION FOR COMPETITIVE QUOTATIONS. All responsible sources who can provide the same equipment may submit a capability statement that could be considered by email (subject line to reference NIAID-NOI-19-1975972) to Tonia Alexander at contact@example.gov, by 11:00 am eastern standard time Wednesday, September 11, 2019. All information furnished must be in writing and must contain sufficient detail to allow NIAID to determine if it can meet the above unique specifications described herein. All responses received by the closing date of this solicitation will be considered by the Government. A determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS