J -- Solar Gas Turbine Maintenance

Active
Reference-Number-F2MTW57269AQ01Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The contract involves a sole source requirement agreement with Solar Turbines Incorporated for maintenance services on two Solar Gas Turbine units located at Wilford Hall Medical Center, Lackland Air Force Base, Texas. The scope includes providing all necessary personnel, equipment, materials, and supervision to conduct four non-scheduled visits for troubleshooting and component replacement, as well as two scheduled maintenance inspections per turbine unit annually, following the manufacturer’s maintenance schedule. The contractor is also responsible for supplying all consumable parts, cleaning the work area after service, and submitting written inspection and maintenance reports. Restrictions include no welding or open flame without a permit, and all personnel must sign in and out when entering or leaving the compound. This firm fixed price contract is set to cover the period from October 5, 2007, through September 30, 2008, with delivery terms FOB Destination. The procurement falls under NAICS code 333611 and is open to all responsible bidders registered in the Central Contractor Registration system with updated online certifications. The contract is managed by the Department of Defense office at JBSA Lackland, TX, with designated points of contact including a Contract Specialist and Contracting Officer, who provide oversight and communication for proposal submissions and administration.

General Info

Sole source contract with Solar Turbines for maintenance of two gas turbines at Lackland AFB.

NAICS

333611 - Turbine and Turbine Generator Set Units Manufacturing

Place of Performance

TX

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA3016 502 Cons Cl
Contacts2 people available
OfficeJBSA LACKLAND, TX, 78236-5286, USA
Office AddressJBSA LACKLAND, TX, 78236-5286, USA
Contacts
Cami L MercadoContract Specialist
David A RamosContracting Officer

Full Description

Show more
Non-Personal Services: The Government intends to solicit and award on a sole source basis a requirement contract to Solar Turbines Incorporated, 22 Pacific Highway, San Diego CA 92186-5376 for the maintenance of the two (2) each Solar Gas Turbines, Package Serial Number: TG97064 and TG97062, Engine Serial Number 0546T and 0303T.for Wilford Hall Medical Center located at Lackland AFB TX, under the authority of FAR 6.302-1. The contractor shall provide all personnel, equipment, tools, materials, supervision and all other items or services necessary to perform four (4) non-schedule visites for maintenance trobule-shooting and component replacement. Contractor shall perform two(2) each scheduled basic maintenance inspections per unit, (semiannual at 4,000 hours and annual at 8,000 hours) in accordance with manufacturers maintenance schedule. Contractor shall provide all consumable parts, provide written reports documenting inspections/maintenance. Contractor shall clean area of all soil, debris and fluids generated. No welding or open flame is permitted without a welding permit from the Lackland Fire Department. All personnel shall sign in and out upon arriving and departing the compond. A firm fixed price contract is contemplated with a Period of Performance of 5 Oct 2007 through 30 Sep 2008. FOB: Destination. The North American Industry Classification System code (NAICS) is 333611. The small business size standard is 1000 employees . All responsible sources may submit a bid, proposal, or quotation which will be considered by this agency. Interested parties must be registered with the Central Contractor Registration (CCR) at http://www.ccr.gov as prescribed in DFAS 252.204-7004 and have their Online Representation and Certifications Application (ORCA) on record at https://orca.bpn.gov . Points of Contact: Cami L. Mercado, Contract Specialist, Phone: 210-671-1718, Fax: 210-671-3360, E-mail: cami.mercado@lackland.af.mil Anastacio D. Ramos, Contracting Officer, Phone: 210-671-1717, Fax: 210-671-3360, E-mail: david.ramos@lackland.af.mil

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Defense → FA3016 502 Cons Cl

Same awarding agency

NAICS: 238210
New
Federal
DCF3 PROJECTION SYSTEM
Solicitation # A070977
The Department of Defense, specifically the 502 Cons Cl under the Office of the Air Force, is issuing a sources-sought Request for Information (RFI) for the DCF3 Projection System, solicitation number A070977. The objective is to identify capable providers for the installation of standalone audio-visual (AV) classroom equipment in sixteen classrooms at the BMT DCF3 (Building 9270) located at JBSA-Lackland, Texas. The scope of work includes providing all personnel, equipment, and materials to install laser projectors, zoom lenses, lecterns, scaling switchers, and associated cabling. The system must operate as a standalone solution and is strictly prohibited from interfacing with the Air Force network. Key deliverables include the integration of Apple Government-Furnished Equipment, the provision of technical documentation, and the delivery of user training for staff. Technical requirements specify that projectors and extension columns must be Trade Agreement Act (TAA) compliant, and touch panels must be FCC Class A certified. The contractor is responsible for ensuring high video resolution and sound quality, with final acceptance based on a post-installation walkthrough and inspection at the project site. Security requirements are stringent, requiring criminal history checks and background investigations for all personnel accessing the base, as well as strict adherence to Force Protection Condition procedures and a total prohibition of weapons on site. This RFI is strictly voluntary and is not a formal solicitation for quotes; interested parties must submit their capabilities and open-market pricing via email to Tommie Low by October 27, 2026, at 10 a.m. CST.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in 7 days
View Details
NAICS: 238220
New
Federal
Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement
Solicitation # A070764SS
The 502d Contracting Squadron is conducting market research via a Sources Sought Synopsis to identify capable industry sources for the turnkey removal and replacement of 48 ceiling-suspended Dedicated Outside Air System Water-Source Heat Pumps at the JBSA Ft Sam Houston San Antonio Military Medical Center Dormitory Annex, specifically in buildings B3631 and B3635. The project is projected as a Firm-Fixed Priced Purchase Order under NAICS code 238220. The contractor must provide all personnel, equipment, and supervision to install units that meet strict technical specifications, including a 1.25-ton capacity, horizontal ceiling-plenum configuration, and the use of low-GWP refrigerants such as R-454B or R-32, as R-410A is strictly prohibited. A critical requirement is that replacement units must fit through existing access openings measuring approximately 3 feet 11.5 inches by 2 feet to avoid structural demolition. The scope of work includes the integration of the units into the central Building Automation System via BACnet IP/MSTP and the use of AHR/ISO 13256-1 certified water-to-refrigerant coaxial heat exchangers. Performance must be completed within 275 days of award. Interested respondents must provide company identification, SAM.gov certifications, and confirmation that technicians hold EPA Section 608 Universal Certifications. Small business prime contractors must also verify they can cover at least 51 percent of the contract cost with their own personnel. Responses are due by October 26, 2026, and must be submitted in PDF format with a maximum length of ten pages, excluding equipment cut sheets.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

6 days ago

DEADLINE

in 6 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award