Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 12, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J045--668-25-2-5058-0051 CON NRM - Boiler Communication Controls

Closed
36C26025Q0328Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811210
New
SLED
INFO/SPSV - VuWall Maintenance Renewal
Solicitation # SRC0000036982
Solicitation SRC0000036982 is for the renewal of managed audiovisual and VuWall system support for the Alabama Department of Corrections at their Montgomery location. The service period runs from October 18, 2026, through October 17, 2027, with a total contract cost limit of 25,000 dollars over a maximum period of five years. The scope of work requires the provider to maintain a 24/7/365 Level 1 service desk for telephone and email intake, with Level 2/3 remote and onsite support available during standard business hours. Key performance metrics include a 95 percent compliance rate for telephone answers under 10 minutes, a 90 percent compliance rate for email responses within 4 hours, and onsite technician arrival within 48 hours of remote troubleshooting. Qualified suppliers must demonstrate technical competency and manufacturer authorization for VuWall TRx, PAK video wall controllers, VuStream encoders, and ControlVu interfaces. The provider is responsible for diagnosing failed equipment, coordinating manufacturer repairs, and delivering monthly service-level reports. Award criteria include pricing reasonableness and the ability to meet strict operational capacities. Compliance requirements include enrollment in E-Verify, certification of Alabama state and local tax remittance, and adherence to ADOC security and background screening protocols. All responses must be submitted electronically through the Alabama Buys system.
Department Of Corrections, Information Systems

POSTED

about 22 hours ago

DEADLINE

in 2 days

General Info

NAICS

811210 - Electronic and Precision Equipment Repair and Maintenance

Place of Performance

4815 North Assembly Street, Spokane, WA, 99205, USA

Set-Aside

SDVOSBC

Documents

1

36C26025Q0328 - Boiler Communication Controls Sources Sought

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Contacts1 person available
OfficeVANCOUVER, WA, 98661, USA
Office AddressVANCOUVER, WA, 98661, USA
Contacts
Kyle BiessenerContract Specialist

Full Description

Show more
THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services: Proposed NAICS Code 811210 is applicable to determine business size standard. Any questions or concerns may be directed to Kyle Biessener via e-mail at kyle.biessener@va.gov. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS: 1.) company name, address, and business size; point of contact name, phone number, and e-mail address. 2.) Capability statement of your firm and any current or historical projects for similar requirements. 3.) How long do you estimate it would take complete the services required? 4.) Can you provide firm-fixed-pricing for the scope of services and supplies required below? 5.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement? DRAFT STATEMENT OF WORK (SOW): Scope Replace, test, and calibrate communication controls and instruments for 4 separate boilers in accordance with ISO 17025 standards and VA Directive 1810. Service will be to replace the current can bus system with a 4-20MA control system. Contractor shall be located within a 120-mile radius of the Spokane VA Medical Center, and shall furnish all materials, tools, and devices needed to complete the work detailed in this document. Place of Performance Work to be performed at the Mann-Grandstaff VA Medical Center, located at 4815 North Assembly Street, Spokane, WA 99205 Technician Qualifications At a minimum, qualified technicians shall: Be employed with an ISO 17025 certified business and have five years of successful experience in the field. The experience should be largely with institutional and industrial boiler plants similar in design to the VAMC plant as specified below. Be certified as competent to perform calibrations in accordance with ISO 17025 standards. Demonstrate familiarity and show proof of compliance with VA directive 1810, and have ready access to the current versions of the following references: - NFPA 85, Boiler and Combustion Systems Hazards Code. - VHA Boiler Plant Safety Device Testing Manual, 8th Edition. - VHA Directive 2008-062 Demonstrate working knowledge of Spokane Air requirements for emission parameters and the ability to perform to these standards. Be equipped with portable electronic flue gas analyzers and other test instruments necessary for the required tests and calibrations. Instruments must be calibrated within six months of the site visits. Be capable of programming digital controls, and possess the appropriate hardware and software needed to accomplish the task. Provide proof of at least 3 years work experience performing the VA s Safety Devices Testing Program. For issues that may arise during the installation period, provide at least a 48-hour response time to address routine issues, and a 2-hour response time to address critical issues. Specific Tasks Provide for each boiler (4 in total): Set of as-built drawings. New control panels. New process controller. New Honeywell BMS or equivalent, including first out annunciator. All Fireye brands are being replaced. New actuators for gas, oil, FD air and FGR control. 4 Per boiler. Provide installation of the above-mentioned equipment, to include startup, gas, and oil. Perform 1 Gas and 1 oil combustion tuning. Perform steam pressure and drum level process tuning. Perform tuning, testing, calibrating, and adjustments of burners in accordance with OCM Instrumentation Testing Criteria. Conduct calibration and certification of control instrumentation in accordance with VA requirements, complete with required paperwork and display stickers. Contractor shall provide at least one week notice to the Person of Contact (POC) prior to performing the work. Work cannot be scheduled during heavy steam load periods. Only one boiler at a time can be out of service for the inspection, testing and calibration procedures. Work must be conducted when the POC or his/her designee is available on site to monitor the work. Boiler Specifications The aforementioned tasks shall be performed on the specified boilers: Boilers 1 & 2 Subtitle: 2X 350 HP Boiler Manufacturer: Burnham Boiler Type: Fire tube Boiler Year Built: 2020 Design Pressure: 200.00 PSI Operating Pressure: 120.00 PSI [relief valve set pressure] Design Temperature: 650.00 degrees Fahrenheit Rated Capacity: 12,000 pounds per hour Fuel: Natural gas and or #2 fuel oil fired boilers. 2 x profiles to be tuned per boiler. Boilers 3 & 4 Subtitle: 2X 200 HP Boiler Manufacturer: Burnham Boiler Type: Fire tube Boiler Year Built: 2020 Design Pressure: 200.00 PSI Operating Pressure: 120.00 PSI [relief valve set pressure] Design Temperature: 650.00 degrees Fahrenheit Rated Capacity: 6900 pounds per hour Fuel: Natural gas and or #2 fuel oil fired boilers. 2 x profiles to be tuned per boiler. Other Pertinent Information or Special Considerations. a. Identification of Possible Follow-on Work. Installing new boiler communication controls could potentially require follow on services. b. Identification of Potential Conflicts of Interest (COI). N/A c. Identification of Non-Disclosure Requirements. Sensitive or proprietary information issues are not applicable to this job. d. Packaging, Packing and Shipping Instructions. N/A. e. Inspection and Acceptance Criteria. The Contract Officer Representative (COR) is responsible for certifying that the work done under the contract is performed to time and standard. They are also responsible to assure the inspection and acceptance of products provided incidental to services. Potential candidates having the capabilities necessary to provide the above stated services are invited to respond to this Sources Sought Notice via e-mail to Kyle Biessener at kyle.biessener@va.gov no later than 03/20/2025 by 4:30 PM Pacific Standard Time. No telephone inquiries will be accepted. Disclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.

More opportunities from Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS