This Sources Sought opportunity from Department Of Veterans Affairs was posted on June 3, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J061--Generator Maintenance

Closed
36C25226Q0504Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238210
New
SLED
Existing Generators Replacement Aguadilla, PR
Solicitation # 872298
This project involves the complete replacement of two existing power generators at the Aguadilla Detention Facility in Aguadilla, Puerto Rico. The scope of work requires the installation of one 100 kW and one 150 kW Perkins diesel generator, both featuring stainless-steel enclosures to protect against salt air and moisture. The installation includes two new NEMA 3R automatic transfer switches, securing the units to the existing concrete slab with Grade 5 or higher galvanized anchor bolts, and performing comprehensive generator load tests. The project is estimated to have a magnitude between $250,000 and $300,000, with a total period of performance of 270 calendar days from the Notice to Proceed. The contract is a Firm-Fixed-Price task order issued under an 8(a) Multiple Award Construction Contract (MACC) IDIQ. Award will be based solely on the lowest total evaluated price, provided the offeror demonstrates technical understanding, a sound implementation approach, and a robust safety and quality control program. Key compliance requirements include adherence to the Buy American Act, Davis-Bacon prevailing wage rates per determination PR20260001, and strict security protocols, including PIV card issuance and non-disclosure agreements for personnel. All work must be performed during regular business hours, Monday through Friday, and must comply with NFPA 70, the International Building Code, and NEC Article 445.
Bristol Alliance of Companies

POSTED

about 11 hours ago

DEADLINE

in 18 days
NAICS: 238210
New
SLED
LED Lighting and Occupancy Sensor Upgrades DRAFT
Solicitation # 872291
The LED Lighting and Occupancy Sensor Upgrade project is a Firm-Fixed-Price task order issued under an 8(a) Multiple Award Construction Contract (MACC) for the Buffalo Federal Detention Facility in Batavia, New York. The project involves providing all engineering, labor, equipment, and materials to upgrade the facility with energy-efficient LED lighting fixtures and occupancy sensors, including the removal and disposal of existing fluorescent fixtures, lamps, and ballasts. The estimated magnitude of the contract is between 2 million and 2.3 million dollars, with a period of performance of 180 calendar days from the notice to proceed. Award will be based solely on the lowest total evaluated price. The contractor is required to adhere to Davis-Bacon Act wage determinations and comply with standards from OSHA, ADA, NFPA, and the International Building Code. Key deliverables include a Quality Control Plan due within 15 days of award, a site survey within 30 days, and a final closeout package consisting of as-built drawings, warranty documentation, and 5 percent attic stock. The contractor must also provide a minimum two-hour training session for facility maintenance personnel and a detailed commissioning report verifying that 100 percent of fixtures and controls were tested. Payment requests must be submitted electronically via the Invoice Processing Platform and accompanied by certified payroll.
Bristol Alliance of Companies

POSTED

about 11 hours ago

DEADLINE

in 18 days
NAICS: 238210
New
SLED
Conex Offices for Forensics Personnel - St. Thomas
Solicitation # 872300
This project involves a Firm-Fixed-Price task order under an 8(a) Multiple Award Construction Contract for the provision and installation of two 40ft steel FLEXTAINER conex offices for forensics personnel at the St. Thomas HSI Facility in the US Virgin Islands. The scope of work includes the construction of 3k PSI reinforced concrete slabs, installation of the units, and equipping each office with two split-system A/C units, R-11 insulation, vinyl flooring, LED lighting, and a steel door with a Cypher lock. Each unit must also include four security windows and a 5-pound ABC fire extinguisher. Electrical connectivity must be established via 2-inch PVC or uPVC conduit to the nearest circuit. The contract has an estimated magnitude between 250,000 and 300,000 dollars, with a period of performance of 364 calendar days from the Notice to Proceed. Award will be based on the lowest total evaluated price, considering technical approach, safety, and quality control plans. Key requirements include compliance with the Buy American Act, adherence to Davis-Bacon prevailing wage rates for the Virgin Islands, and strict security protocols, including the signing of DHS Non-Disclosure Agreements and mandatory cybersecurity training. Contractors must conduct a site survey prior to proposal submission and provide a detailed project schedule within 15 days of the Notice to Proceed. All invoicing must be processed through the Invoice Processing Platform and accompanied by certified payroll.
Bristol Alliance of Companies

POSTED

about 11 hours ago

DEADLINE

in 18 days
NAICS: 238210
New
IE JCC Fire Alarm Repairs
Solicitation # Inland Empire Fire Alarm Deficiencies (169706,169708,169733,169736 & 16937)
Management and Training Corporation (MTC), acting as the operator for the Inland Empire Job Corps Center, is soliciting subcontractor bids for a fixed-price, single lump sum contract to correct fire alarm deficiencies at the facility in San Bernardino, California. The scope of work includes the installation of SD500-PS and Notifier BNG-1 manual pull stations, the installation of Cooper Wheelock HSW and Model 757-3A-T horn/strobe notification appliances, and the replacement of six existing fire alarm bells with Cooper Wheelock HSW units. All new devices must be integrated into the existing system and undergo complete functional testing. The project is estimated between 0 and 25,000 dollars, with a performance period of 90 consecutive business days following the notice to proceed. Bids are due by September 16, 2026, and will be evaluated based on overall best value. This opportunity is set aside for various small business categories, including SDB, WOSB, HUBZone, and SDVOSB, under NAICS code 238210. The contract is subject to Construction Wage Rate Requirements, necessitating weekly certified payroll and adherence to California prevailing wage determinations. For bids of 25,000 dollars or more, a bid bond of 20 percent is required, along with performance and payment bonds from a surety company with at least an A- rating. Awardees must provide a Unique Entity ID (UEI) and complete the MTC Supplier Packet. Final acceptance is contingent upon a two-stage inspection process involving a substantial completion punch list and a final inspection approved by the center and government representatives.
Inland Empire Job Corps

POSTED

about 11 hours ago

DEADLINE

in 5 days

AI Contract Overview

Show more

The Edward Hines Jr. VA Hospital requires a contractor to perform comprehensive load bank testing and preventive maintenance on twenty critical backup generators that support life safety and patient care across the campus. The scope includes all labor, materials, equipment, and documentation necessary to conduct scheduled maintenance at two levels—PM Level 1 in January and PM Level 2 in July—with annual load bank testing in September. Load bank testing follows a strict sequence: idle readings, followed by incremental loading at 30%, 50%, 75%, and 100% of generator capacity for designated durations, with real-time monitoring and data recording of amps, volts, oil pressure, coolant temperature, fuel pressure, frequency, and kW output. PM Level 1 involves inspections of fuel, cooling, air induction, lubrication, starting, and electrical systems, along with laboratory fuel sampling per ASTM standards and full oil analysis. PM Level 2 includes a full oil and filter change during the base year, with subsequent oil changes based on usage or manufacturer guidelines, and comprehensive assessment of the Emergency Power Supply System for vibration, leaks, overheating, abnormal noise, and component deterioration. All maintenance and testing must comply with Veteran Health Agency Directive 1028, NFPA 99, NFPA 110, Joint Commission standards, ASTM fuel testing protocols, OEM guidance, VA Engineering policies, and applicable federal, state, and local regulations. Services must occur Monday through Friday from 7:00 am to 4:00 pm CST, with all activities coordinated one week in advance with the Hines VA Engineering Department. Upon arrival, contractors must report in and out to the assigned shop. Every service must be documented on a legible contractor service report signed by the Contracting Officer’s Representative (COR) at the time of performance, and a complete Engineering Service Report (ESR) must be submitted within 30 days of load bank testing, containing operational data, identified deficiencies, repair recommendations with priority classifications, cost estimates, fuel test results, oil analysis, and before-and-after documentation. Custom ESR formats require prior COR approval. The contract has a five-year potential term, beginning September 1, 2026, with four optional one-year periods extending through August 31, 2031. Deviations from the schedule require written COR approval, and all equipment must be returned to automatic mode and fully operational after each service. The solicitation is a sources sought notice for market research, targeting qualified vendors with

General Info

Provide maintenance and annual load testing for 20 hospital generators, ensuring safety and compliance.

Agency

Department Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)View Agency

NAICS

238210 - Electrical Contractors and Other Wiring Installation ContractorsView NAICS

Place of Performance

Edward Hines, Jr. VA Hospital 5000 South 5th Avenue, WI

Set-Aside

NONE

Documents

(1)

36C25226Q0504.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)
Contacts1 person available
OfficeMILWAUKEE, WI, 53214, USA
Organization / Agency
Department Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)
View Agency Profile
Office AddressMILWAUKEE, WI, 53214, USA
Contacts

Full Description

Show more
Scope of Work Edward Hines Jr. VA hospital requires the services of a contractor to perform load bank testing, and maintenance for (20) generators. These generators provide backup power and have a direct impact on patient health and life safety throughout the Hines VA Campus. The Contractor shall furnish all labor, management, materials, equipment to perform preventive maintenance, inspection, calibration, testing and documentation for the generators listed on the equipment listing.
Place of Performance Edward Hines Jr. VA hospital 5000 S. 5th Avenue, Hines, Illinois 60141
Period of Performance Base Year: September 1 ,2026 through August 31,2027 Option Year 1: September 1, 2027, through August 31, 2028 Option Year 2: September 1, 2028, through August 31, 2029 Option Year 3: September 1, 2029, through August 31, 2030 Option Year 4: September 1, 2030, through August 31, 2031
Schedule Load Bank Testing shall be performed in September Preventive Maintenance (PM) Level 1 shall be performed in January. Preventive Maintenance (PM) Level 2 shall be performed in July. Any deviations from this schedule shall only be made with prior approval from the Contracting Officer Representative (COR) Description of Services Load Bank Testing Specifications: The generators shall be load tested using the following sequence: Idle / No-Load Readings. Baseline data recorded before applying load. 30% of Generator Load Rating for 30 minutes 50% of Generator Load Rating for next 30 minutes 75% of Generator Load Rating for 60 minutes (1 hour) 100% of Generator Load Rating for 60 minutes (1 hour) Preventive Maintenance - Level 1 The Contractor shall perform: Fuel System Inspect main tank and day tank for leaks, level, condition Drain water traps/separators Inspect primary/secondary filters; clean primary filter Check governor, controls, linkages, and oil level Inspect fuel lines, brackets, and connections Check fuel pressure gauge for correct operation Cooling System Inspect radiator/heat exchanger (leaks, debris, louvers) Inspect coolant level and condition; test protection level Inspect hoses and connections for deterioration Inspect/lubricate fan pulleys, fan bearings; check clearance Inspect fan belts (wear, tension) Inspect jacket water heater and thermostat setting Inspect water pump for leaks/noise Air Induction & Exhaust Inspect/clean primary & secondary air filters; reset indicators Inspect air inlet piping, housings, gaskets Inspect turbocharger (leaks, noise) Inspect exhaust manifold (hardware, leakage, oil slobber) Inspect muffler/silencer and piping for damage or corrosion Lubrication System Inspect oil level and contamination; inspect for leaks Check oil pressure gauge for correct readings Inspect pre lube pump Inspect crankcase breather and hoses Perform full oil analysis (wear metals, contaminants, debris) Starting System Inspect batteries (condition, leakage, terminals) Check electrolyte level & specific gravity (if applicable) Inspect battery charger, wiring, terminals Inspect starting motor (connections, noise, operation) Inspect alternator & drive components Engine Monitors & Safety Controls Test all engine safety devices (oil pressure, coolant temp, overspeed, over crank, etc.) Test remote annunciators and local alarm systems Generator & Electrical Components Remove and inspect brushes, clean slip rings Inspect space heaters for proper operation Inspect control panel (manual/auto start, meters, adjustments) Verify voltmeter and ammeter readings Laboratory fuel sampling, including but not limited to: Accelerated Aging Suspended Particulates Association for Material Protection and Performance (AMPP) Corrosion inspection Organic Material Water (suspended content) Operational Test Requirements Cold engine start observation 30 minute operating run Monitoring for leaks, noise, vibration Verification of all safety shutdowns Recording of: Amps Volts Oil pressure Coolant temperature Fuel pressure Frequency Real power (kW output) Timing and functional verification of: Signal delay Engine start time Load pickup Automatic transfer switch (ATS) operation Re transfer timing Restoration to Service Day Tank and Fuel System Functional Testing Contractor shall conduct operational checks of the day tank, including: Float switch operation Transfer pump operation Solenoid valve performance (if equipped) Inspection of all fuel lines, hoses, connectors, and fittings for wear, corrosion, or leaks Preventive Maintenance - Level 2 The Contractor shall perform: Fuel System Inspect main and day tank for leaks and fuel level Drain water traps/separators Inspect fuel lines, fittings, and brackets for leaks or looseness Inspect governor oil level, linkages, and controls; add oil as needed Inspect/clean primary and secondary fuel filters Inspect fuel pressure gauge for correct operation Inspect fuel condition for contaminants Cooling System Inspect radiator/heat exchanger for leaks, debris, damage Verify louver operation Inspect coolant level, rust, oil contamination, top off to maintain serviceable level Check coolant conditioner concentration and freeze/boil protection Inspect filler cap sealing surfaces and gasket Inspect hoses for deterioration; tighten connections Lube and inspect fan-drive bearings and pulleys Inspect fan belts for wear; adjust tension Verify jacket water heater operation and thermostat setting Inspect water pump for leaks, noise, or malfunction Air Induction & Exhaust System Inspect and clean primary/secondary air filters; reset indicators. Inspect air inlet piping, housings, seals, and gaskets Inspect turbocharger for oil or exhaust leakage, check for abnormal noise Inspect exhaust manifold for leakage, missing hardware, oil slobber Inspect exhaust muffler and piping for corrosion or damage Lube Oil System Provide a full oil and filter change for all 20 generators during the base year. Thereafter in the option years, change the oil filter every year and the oil every 250 hours or as needed based on the oil and filter inspection or the manufacturers requirements. Inspect oil level and contamination, top off to maintain serviceable level Inspect generator and engine for leaks Inspect pre lube pump operation Inspect gaskets and seals for deterioration Inspect crankcase breather operation and blow-by condition Perform full oil analysis (wear metals, contamination, debris) Provide oil analysis results to VA with NFPA acceptable thresholds Starting and Charging System Inspect batteries for damage or leakage; clean/tighten terminals Check battery electrolyte level and specific gravity (if applicable) Inspect battery charger (operation, wiring, connections) Inspect starting motor wiring and operation, check for abnormal noise Inspect alternator condition, voltage output, belts, and pulleys Engine Monitors & Safety Controls Test all engine safety shutdowns (oil pressure, coolant temp, over crank, overspeed) Inspect annunciators and remote alarm systems Check gauge accuracy (oil pressure, temperature, alternator) Generator & Mechanical Components Remove and inspect brushes; clean slip rings; make adjustments Lubricate generator rear bearing Inspect vibration isolators for wear and adjust to manufacturers specifications Control Panel & ATS Test manual/auto start controls Verify correct voltmeter readings (voltage level, gain, drop) Test ammeter with baseline load and no load readings Inspect circuit breakers for tightness and free movement Inspect ATS mechanical and electrical condition Operational Test to include at a minimum: Cold start observation 30 minute operating run Monitoring for abnormal vibration, leak, noise Verification of safety shutdown devices Documenting: Amps & volts Oil pressure Water temperature Fuel pressure Frequency Kilowatt output Timing and verification of: Signal delay Engine start time Load pickup Automatic transfer Load return (re transfer) General Emergency Power Supply System (EPSS) Condition Assessment During all PM 2 activities, the Contractor shall assess and document the overall condition of the EPSS including: Vibration issues Leaks (fuel, oil, coolant, exhaust) Excessive temperature Abnormal noises Component wear, corrosion, or deterioration Any condition that may indicate impending failure Contractor shall restore generator and EPSS to automatic mode Ensure all equipment is fully operational Reports and Documentation ESR (Engineering Service Report) The ESR shall at a minimum include: Building Number Test Date Start Time / Stop Time Generator make, model, serial number kW/kVA rating Fuel type Hours of operation Location/Building number ATS identifier (if tested) Hour Meter Start / Hour Meter Finish Engine Oil Pressure Engine Water Temperature Exhaust Gas Temperature (IR, pre turbo) Frequency (Hz / cycles) Voltage readings Generator Loading (Amperage per phase) Name and Signature of Technician All completed inspection checklists All measured data and test results Photos or quantifiable evidence before and after repairs, when applicable All identified deficiencies List of required and recommended repairs with priority classifications Itemized cost estimates Complete PM 1 test data ASTM laboratory fuel test results Oil analysis report A complete Load Bank ESR shall be submitted to the COR within 30 days of the test completion. The contractor may create a customized ESR, but it must be approved by COR before implementation The contractor shall document the services rendered on a legible, contractor service report and submit it to the COR for certification (signature) A copy of the signed service report must be provided to the COR by the contractor at the time the service is provided. If the COR is unavailable, a signed, authorized copy of the ESR will be sent to the Contractor after the work can be reviewed (if requested or noted on the ESR).
Requirements and Qualifications Contractor shall have knowledge of and ensure compliance with the current version of the following throughout all performance and reporting requirements. Veteran Health Agency Directive 1028 NFPA 99 and NFPA 110 Joint Commission standards local, state, and federal regulations ASTM fuel testing standards OEM guidance VA Engineering policies Facility Check In Upon arrival at the Edward Hines Jr VA Hospital, the contractor shall be required to report when on-site and when services are completed with assigned shop. Hours The Contractor will coordinate and schedule all test(s) with Hines VA Engineering Department (1) week Prior to onsite visit. The Contractor is required to perform work and tests during normal work hours, Monday through Friday 7:00 am to 4:00 pm. CST.

More opportunities from Department Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)

Same awarding agency

NAICS: 238220
New
Federal
Z1DA--Construction of Heat Exchangers, Ogden and Damen Building
Solicitation # 36C25226B0034
Solicitation 36C25226B0034 is a request for construction services issued by the Department of Veterans Affairs for the replacement of four steam-to-hot-water converters and heat exchangers at the Jesse Brown VA Medical Center in Chicago, Illinois. The project scope includes the removal of existing units, installation of new heat exchangers, reconnection of piping and electrical power, replacement of steam traps and shutoff valves, reinsulation, and leak testing. This effort is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Business (SDVOSB) firms under NAICS code 238220, with a construction cost magnitude exceeding 250,000 dollars. The required period of performance is 90 days from the issuance of the notice to proceed. The contract mandates strict adherence to personnel security and vetting requirements, including background investigations and the use of Personal Identification Verification (PIV) cards for access to VA facilities and sensitive information. Contractors are responsible for the coordination and actions of all subcontractors, and the government maintains the right to reject incompetent or objectionable personnel. For contract changes, specific protocols are established for equitable adjustment proposals, including itemized breakdowns for changes exceeding the micro-purchase threshold and a tiered scale for negotiating overhead and profit on changes of 500,000 dollars or less. Additionally, the contractor must certify compliance with VA limitations on subcontracting and adhere to prevailing wage rates for Cook County, Illinois.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

4 days ago

DEADLINE

in 9 days
View Details
NAICS: 238160
New
Federal
Z1DA--550-27-111 B58 Roof Repair
Solicitation # 36C25226B0038
Solicitation 36C25226B0038 is a lump sum, sealed bid project for the repair and replacement of the roofing on Building B58 at the VA Illiana Healthcare System in Danville, Illinois. This procurement is a 100 percent set-aside for CVE Verified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms, with an estimated project magnitude between 250,000 and 500,000 dollars. The scope of work includes removing existing roofing materials, installing new OSB decking, applying new underlayment and asphalt shingles, and replacing flashing as needed. The project must be completed within 60 calendar days from the Notice to Proceed and includes a one-year parts and labor warranty. The award will be granted to the responsible, certified SDVOSB bidder who submits the lowest responsive bid. Bidders must provide a bid guarantee via Standard Form 24 for 20 percent of the bid price or 215,000 dollars, whichever is less, and must furnish performance and payment bonds. Key requirements include compliance with union prevailing wage rates, adherence to VA cybersecurity and safety policies, and the presence of an OSHA certified competent person on site. Amendment 0001 updated the response deadline to September 23, 2026, at 1:00 PM CST. All submissions must include a completed Standard Form 1442 and the VAAR 852.219-75 Certificate of Compliance to be considered responsive.
Roofing Contractors

POSTED

4 days ago

DEADLINE

in 12 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS