This Sources Sought opportunity from Department Of Veterans Affairs was posted on June 3, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J061--Generator Maintenance

Closed
36C25226Q0504Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency is soliciting proposals under RFP-VC-26-010 for transformer oil testing services to enhance the reliability, safety, and maintainability of its transformers across six locations, including RP-1, RP-2, RP-4, RP-5, CCWRF, and CDA. The scope of work comprises three primary objectives: performing visual and infrared thermographic inspections to identify thermal anomalies, installing standardized external oil sampling devices for safer collection, and conducting comprehensive oil testing analysis. Additionally, the contractor is required to evaluate nitrogen blanket systems to ensure positive pressure and provide on-site training for up to 20 agency staff members on inspection tools and defect identification. All work must adhere to NETA MTS, IEEE, NFPA 70E, and ASTM D923 standards, with infrared inspections performed by technicians certified to ASNT Level 1 or higher. This is a fixed-pricing contract with a not-to-exceed total price, intended as a single award to the most capable and cost-effective offeror. Evaluation criteria include the proposer's past performance, specifically requiring at least two similar projects completed within the last five years, as well as the proposed staffing plan, methodology, and fee structure. Proposals must be submitted electronically via PlanetBids by December 23, 2026, and must include a detailed company profile, project approach, and various required forms such as a Non-Collusion Statement and Workers Compensation Certificate. Selected contractors must be registered with the Department of Industrial Relations as public works contractors and must accept electronic payments via ACH.
Inland Empire Utilities Agency

POSTED

about 3 hours ago

DEADLINE

in about 2 months
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management and Training Corporation is soliciting bids for a fixed-price, single lump sum contract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project involves the inspection, repair, and certification of emergency lighting systems to ensure compliance with NFPA 101 (2024 Edition) and NFPA 70 standards. The contractor is responsible for inventorying all fixtures, performing functional testing by simulating utility outages, applying durable tracking labels to each fixture, and integrating recurring maintenance into the facility's Computerized Maintenance Management System. The estimated contract value ranges between $25,000 and $100,000. Bids are due by December 1, 2026, and must be submitted via email to Sandra Clore. A mandatory physical site visit and signature on the attendance roster are required prior to bid submission. For bids equal to or greater than $25,000, contractors must provide a bid bond guarantee of 20% of the base bid, and the awarded contractor will be required to provide performance and payment bonds from a surety company with at least an A- rating. Evaluation is based on overall best value. The contract is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications. Compliance requirements include adherence to the Davis-Bacon Act, Federal Contractor Minimum Wage requirements, and Executive Order 13706 regarding paid sick leave. Contractors must provide certificates of disposal for hazardous materials and manufacturer warranties for all equipment and workmanship. Final payment is contingent upon a joint substantial completion inspection and the resolution of any punch list items.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

The Edward Hines Jr. VA Hospital requires a contractor to perform comprehensive load bank testing and preventive maintenance on twenty critical backup generators that support life safety and patient care across the campus. The scope includes all labor, materials, equipment, and documentation necessary to conduct scheduled maintenance at two levels—PM Level 1 in January and PM Level 2 in July—with annual load bank testing in September. Load bank testing follows a strict sequence: idle readings, followed by incremental loading at 30%, 50%, 75%, and 100% of generator capacity for designated durations, with real-time monitoring and data recording of amps, volts, oil pressure, coolant temperature, fuel pressure, frequency, and kW output. PM Level 1 involves inspections of fuel, cooling, air induction, lubrication, starting, and electrical systems, along with laboratory fuel sampling per ASTM standards and full oil analysis. PM Level 2 includes a full oil and filter change during the base year, with subsequent oil changes based on usage or manufacturer guidelines, and comprehensive assessment of the Emergency Power Supply System for vibration, leaks, overheating, abnormal noise, and component deterioration. All maintenance and testing must comply with Veteran Health Agency Directive 1028, NFPA 99, NFPA 110, Joint Commission standards, ASTM fuel testing protocols, OEM guidance, VA Engineering policies, and applicable federal, state, and local regulations. Services must occur Monday through Friday from 7:00 am to 4:00 pm CST, with all activities coordinated one week in advance with the Hines VA Engineering Department. Upon arrival, contractors must report in and out to the assigned shop. Every service must be documented on a legible contractor service report signed by the Contracting Officer’s Representative (COR) at the time of performance, and a complete Engineering Service Report (ESR) must be submitted within 30 days of load bank testing, containing operational data, identified deficiencies, repair recommendations with priority classifications, cost estimates, fuel test results, oil analysis, and before-and-after documentation. Custom ESR formats require prior COR approval. The contract has a five-year potential term, beginning September 1, 2026, with four optional one-year periods extending through August 31, 2031. Deviations from the schedule require written COR approval, and all equipment must be returned to automatic mode and fully operational after each service. The solicitation is a sources sought notice for market research, targeting qualified vendors with

General Info

Provide maintenance and annual load testing for 20 hospital generators, ensuring safety and compliance.

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Place of Performance

Edward Hines, Jr. VA Hospital 5000 South 5th Avenue, WI

Set-Aside

NONE

Documents

1

36C25226Q0504.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)
Contacts1 person available
OfficeMILWAUKEE, WI, 53214, USA
Office AddressMILWAUKEE, WI, 53214, USA
Contacts

Full Description

Show more
Scope of Work Edward Hines Jr. VA hospital requires the services of a contractor to perform load bank testing, and maintenance for (20) generators. These generators provide backup power and have a direct impact on patient health and life safety throughout the Hines VA Campus. The Contractor shall furnish all labor, management, materials, equipment to perform preventive maintenance, inspection, calibration, testing and documentation for the generators listed on the equipment listing.
Place of Performance Edward Hines Jr. VA hospital 5000 S. 5th Avenue, Hines, Illinois 60141
Period of Performance Base Year: September 1 ,2026 through August 31,2027 Option Year 1: September 1, 2027, through August 31, 2028 Option Year 2: September 1, 2028, through August 31, 2029 Option Year 3: September 1, 2029, through August 31, 2030 Option Year 4: September 1, 2030, through August 31, 2031
Schedule Load Bank Testing shall be performed in September Preventive Maintenance (PM) Level 1 shall be performed in January. Preventive Maintenance (PM) Level 2 shall be performed in July. Any deviations from this schedule shall only be made with prior approval from the Contracting Officer Representative (COR) Description of Services Load Bank Testing Specifications: The generators shall be load tested using the following sequence: Idle / No-Load Readings. Baseline data recorded before applying load. 30% of Generator Load Rating for 30 minutes 50% of Generator Load Rating for next 30 minutes 75% of Generator Load Rating for 60 minutes (1 hour) 100% of Generator Load Rating for 60 minutes (1 hour) Preventive Maintenance - Level 1 The Contractor shall perform: Fuel System Inspect main tank and day tank for leaks, level, condition Drain water traps/separators Inspect primary/secondary filters; clean primary filter Check governor, controls, linkages, and oil level Inspect fuel lines, brackets, and connections Check fuel pressure gauge for correct operation Cooling System Inspect radiator/heat exchanger (leaks, debris, louvers) Inspect coolant level and condition; test protection level Inspect hoses and connections for deterioration Inspect/lubricate fan pulleys, fan bearings; check clearance Inspect fan belts (wear, tension) Inspect jacket water heater and thermostat setting Inspect water pump for leaks/noise Air Induction & Exhaust Inspect/clean primary & secondary air filters; reset indicators Inspect air inlet piping, housings, gaskets Inspect turbocharger (leaks, noise) Inspect exhaust manifold (hardware, leakage, oil slobber) Inspect muffler/silencer and piping for damage or corrosion Lubrication System Inspect oil level and contamination; inspect for leaks Check oil pressure gauge for correct readings Inspect pre lube pump Inspect crankcase breather and hoses Perform full oil analysis (wear metals, contaminants, debris) Starting System Inspect batteries (condition, leakage, terminals) Check electrolyte level & specific gravity (if applicable) Inspect battery charger, wiring, terminals Inspect starting motor (connections, noise, operation) Inspect alternator & drive components Engine Monitors & Safety Controls Test all engine safety devices (oil pressure, coolant temp, overspeed, over crank, etc.) Test remote annunciators and local alarm systems Generator & Electrical Components Remove and inspect brushes, clean slip rings Inspect space heaters for proper operation Inspect control panel (manual/auto start, meters, adjustments) Verify voltmeter and ammeter readings Laboratory fuel sampling, including but not limited to: Accelerated Aging Suspended Particulates Association for Material Protection and Performance (AMPP) Corrosion inspection Organic Material Water (suspended content) Operational Test Requirements Cold engine start observation 30 minute operating run Monitoring for leaks, noise, vibration Verification of all safety shutdowns Recording of: Amps Volts Oil pressure Coolant temperature Fuel pressure Frequency Real power (kW output) Timing and functional verification of: Signal delay Engine start time Load pickup Automatic transfer switch (ATS) operation Re transfer timing Restoration to Service Day Tank and Fuel System Functional Testing Contractor shall conduct operational checks of the day tank, including: Float switch operation Transfer pump operation Solenoid valve performance (if equipped) Inspection of all fuel lines, hoses, connectors, and fittings for wear, corrosion, or leaks Preventive Maintenance - Level 2 The Contractor shall perform: Fuel System Inspect main and day tank for leaks and fuel level Drain water traps/separators Inspect fuel lines, fittings, and brackets for leaks or looseness Inspect governor oil level, linkages, and controls; add oil as needed Inspect/clean primary and secondary fuel filters Inspect fuel pressure gauge for correct operation Inspect fuel condition for contaminants Cooling System Inspect radiator/heat exchanger for leaks, debris, damage Verify louver operation Inspect coolant level, rust, oil contamination, top off to maintain serviceable level Check coolant conditioner concentration and freeze/boil protection Inspect filler cap sealing surfaces and gasket Inspect hoses for deterioration; tighten connections Lube and inspect fan-drive bearings and pulleys Inspect fan belts for wear; adjust tension Verify jacket water heater operation and thermostat setting Inspect water pump for leaks, noise, or malfunction Air Induction & Exhaust System Inspect and clean primary/secondary air filters; reset indicators. Inspect air inlet piping, housings, seals, and gaskets Inspect turbocharger for oil or exhaust leakage, check for abnormal noise Inspect exhaust manifold for leakage, missing hardware, oil slobber Inspect exhaust muffler and piping for corrosion or damage Lube Oil System Provide a full oil and filter change for all 20 generators during the base year. Thereafter in the option years, change the oil filter every year and the oil every 250 hours or as needed based on the oil and filter inspection or the manufacturers requirements. Inspect oil level and contamination, top off to maintain serviceable level Inspect generator and engine for leaks Inspect pre lube pump operation Inspect gaskets and seals for deterioration Inspect crankcase breather operation and blow-by condition Perform full oil analysis (wear metals, contamination, debris) Provide oil analysis results to VA with NFPA acceptable thresholds Starting and Charging System Inspect batteries for damage or leakage; clean/tighten terminals Check battery electrolyte level and specific gravity (if applicable) Inspect battery charger (operation, wiring, connections) Inspect starting motor wiring and operation, check for abnormal noise Inspect alternator condition, voltage output, belts, and pulleys Engine Monitors & Safety Controls Test all engine safety shutdowns (oil pressure, coolant temp, over crank, overspeed) Inspect annunciators and remote alarm systems Check gauge accuracy (oil pressure, temperature, alternator) Generator & Mechanical Components Remove and inspect brushes; clean slip rings; make adjustments Lubricate generator rear bearing Inspect vibration isolators for wear and adjust to manufacturers specifications Control Panel & ATS Test manual/auto start controls Verify correct voltmeter readings (voltage level, gain, drop) Test ammeter with baseline load and no load readings Inspect circuit breakers for tightness and free movement Inspect ATS mechanical and electrical condition Operational Test to include at a minimum: Cold start observation 30 minute operating run Monitoring for abnormal vibration, leak, noise Verification of safety shutdown devices Documenting: Amps & volts Oil pressure Water temperature Fuel pressure Frequency Kilowatt output Timing and verification of: Signal delay Engine start time Load pickup Automatic transfer Load return (re transfer) General Emergency Power Supply System (EPSS) Condition Assessment During all PM 2 activities, the Contractor shall assess and document the overall condition of the EPSS including: Vibration issues Leaks (fuel, oil, coolant, exhaust) Excessive temperature Abnormal noises Component wear, corrosion, or deterioration Any condition that may indicate impending failure Contractor shall restore generator and EPSS to automatic mode Ensure all equipment is fully operational Reports and Documentation ESR (Engineering Service Report) The ESR shall at a minimum include: Building Number Test Date Start Time / Stop Time Generator make, model, serial number kW/kVA rating Fuel type Hours of operation Location/Building number ATS identifier (if tested) Hour Meter Start / Hour Meter Finish Engine Oil Pressure Engine Water Temperature Exhaust Gas Temperature (IR, pre turbo) Frequency (Hz / cycles) Voltage readings Generator Loading (Amperage per phase) Name and Signature of Technician All completed inspection checklists All measured data and test results Photos or quantifiable evidence before and after repairs, when applicable All identified deficiencies List of required and recommended repairs with priority classifications Itemized cost estimates Complete PM 1 test data ASTM laboratory fuel test results Oil analysis report A complete Load Bank ESR shall be submitted to the COR within 30 days of the test completion. The contractor may create a customized ESR, but it must be approved by COR before implementation The contractor shall document the services rendered on a legible, contractor service report and submit it to the COR for certification (signature) A copy of the signed service report must be provided to the COR by the contractor at the time the service is provided. If the COR is unavailable, a signed, authorized copy of the ESR will be sent to the Contractor after the work can be reviewed (if requested or noted on the ESR).
Requirements and Qualifications Contractor shall have knowledge of and ensure compliance with the current version of the following throughout all performance and reporting requirements. Veteran Health Agency Directive 1028 NFPA 99 and NFPA 110 Joint Commission standards local, state, and federal regulations ASTM fuel testing standards OEM guidance VA Engineering policies Facility Check In Upon arrival at the Edward Hines Jr VA Hospital, the contractor shall be required to report when on-site and when services are completed with assigned shop. Hours The Contractor will coordinate and schedule all test(s) with Hines VA Engineering Department (1) week Prior to onsite visit. The Contractor is required to perform work and tests during normal work hours, Monday through Friday 7:00 am to 4:00 pm. CST.

More opportunities from Department Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)

Same awarding agency

NAICS: 621511
New
Federal
Q301--Blood Donor Panel Testing for Captain James A. Lovell Federal Health Care Center (FHCC)
Solicitation # 36C25227Q0071
The Department of Veterans Affairs is conducting market research via a sources sought synopsis to identify qualified providers for blood donor panel testing services at the Captain James A. Lovell Federal Health Care Center in North Chicago, Illinois. This requirement, categorized under NAICS code 621511 for Medical Laboratories, involves a five year ordering period consisting of five one year priced periods starting March 1, 2027. The selected contractor must provide all labor, materials, and expertise to perform a variety of tests, including standard donor panels, Anti-CMV, Chagas Antibody, West Nile Virus, and Babesia DNA/RNA, with estimated annual quantities ranging from 15 to 6,200 tests per category. The contractor must adhere to strict regulatory standards from the FDA, AABB, CAP, TJC, OSHA, CDC, and Department of Defense. Key performance requirements include a 95 percent success rate for reporting results within 24 hours of specimen receipt, with confirmation testing completed within seven calendar days. The contractor is responsible for providing specimen shipment containers and maintaining all necessary certifications, including CLIA and FDA approvals. The government reserves the right to conduct physical inspections of the contractor's facilities. Interested parties must submit organizational details and tailored capability statements by November 3, 2026, to help the government determine if the contract will be a small business set-aside, sole sourced, or open for full competition.
Medical Laboratories

POSTED

about 21 hours ago

DEADLINE

in 6 days
View Details
NAICS: 238220
New
Federal
J041--Condenser Coils Replacement for the VA Illiana Health Care System (VAIHCS), located at 1900 E. Main Street, Danville, IL 61832.
Solicitation # 36C25227Q0051
Solicitation 36C25227Q0051 is a firm-fixed-price request for quote issued by the Department of Veterans Affairs for the OEM-approved replacement of condenser coils for CGAM060F2A chiller Circuits 1 and 2 at the VA Illiana Health Care System in Danville, Illinois. This procurement is set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 238220. The scope of work includes recovering refrigerant per EPA Section 608, removing existing coils, installing new OEM-compliant coils, and performing comprehensive pressure and leak testing. The contractor must provide a final commissioning report and adhere to a strict performance period of thirty calendar days following the Notice to Proceed, with initial submittals and safety plans due within five business days of award. Award will be based on a comparative evaluation of price and other factors, including demonstrated experience with similar HVAC/chiller coil replacements, familiarity with Trane CGAM-series equipment, and required certifications such as EPA Section 608 and OSHA 10/30. The contractor is required to provide a competent superintendent per FAR 52.236-6 and comply with Department of Labor Wage Determination No. 2015-5021 for Vermilion County, Illinois. Key administrative requirements include a 50 percent limitation on payments to non-SDVOSB or non-VOSB firms and strict adherence to Controlled Unclassified Information (CUI) protocols. Quotes are due by November 4, 2026.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 21 hours ago

DEADLINE

in 8 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS