Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

J063--SOURCES SOUGHT NOTICE - PARKING GATE SYSTEM REPLACEMENT, REMOTE MONITORING, PIV BADGE READER INTEGRATION AND SERVICE AGREEMENT FOR THE WASHINGTON DC VAMC

Open
36C24527Q0083Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

561621 - Security Systems Services (except Locksmiths)

Place of Performance

Department of Veterans Affairs Washington DC VA Medical Center, Washington, DC, 20422, USA

Set-Aside

NONE

Documents

1
DOCX, High priority: read this first8 pages · sources-sought
High

Read the document

Due in 22 days

Every page of every file, in your free workspace.

Read the document

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Due in 22 days

Everything you need to bid on this one

Open the full contract in your free workspace.

  • 1 solicitation documentRead every page
  • Buyer contactEmail and phone
Open the full contract

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA

Full Description

Show more
SUMMARY The Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Network Contracting Office (NCO) 5, is issuing this Sources Sought Notice to identify vendors that are interested in and capable of providing the required services. The Washington DC VA Medical Center requires a contractor to provide a Parking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and 5 year Service Agreement for the facility. Interested vendors should review the Statement of Work (SOW) to determine the specific services required. NCO 5 is seeking responses from firms that are interested in this procurement and possess the resources, capabilities, and qualifications necessary to perform these services. Anticipated NAICS CODE 561621 Security Systems Services (except Locksmiths), PSC CODE J063 Please submit your capabilities statement and provide responses to all questions listed below. SOURCES SOUGHT NOTICE: 36C24527Q0083 1. Business name (including Unique Entity ID (SAM.gov) 2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and 3. Person of contact (including telephone number & email address). 4. Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities. 5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (including applicable NAICS) 6. Brief Summary of categories of services that your company can/cannot provide. 7. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable) 8. Confirmation that your organization has the capability and expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response:
a. Do you intend to self-perform this effort? b. If you are located outside the immediate area, how will you self-perform? c. Or do you intend to subcontract work under this contract? If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting?
Response Instructions: Respond to this Notice 36C24527Q0083 by 12-15-2026 @ 10 AM ET. Send all responses to Sign up to see this detail
Subject line on email: 36C24527Q0083 Sources Sought Notice | Company Name STATEMENT OF WORK Parking Gate System Replacement, Remote Monitoring, PIV Badge Reader Integration and Service Agreement Department of Veterans Affairs | Washington DC VA Medical Center 50 Irving Street NW, Washington, DC 20422 Draft dated October 27, 2026 1. BACKGROUND The Washington DC VA Medical Center (VAMC) controls vehicle access to its parking areas, service drives and the separated Fisher House locations through nineteen (19) automated gates: eighteen (18) barrier-arm gates and one (1) slide gate at Utility Building 8. The existing gate operators are at end of service life, depend on in-ground loop detectors in deteriorated asphalt, and experience frequent vehicle strikes and extended downtime. The existing card readers at the gates are not uniformly capable of reading Personal Identity Verification (PIV) credentials, and VA Police Service cannot centrally manage parking-area access. VA requires (a) replacement of the gate operating equipment with commercial, high-duty equipment and above-ground vehicle detection, (b) remote status monitoring, event cameras and remote gate control for authorized VA personnel, (c) all-new PIV badge readers at each gate, furnished and installed by Johnson Controls, Inc. (JCI) as a subcontractor to the prime, and integrated into the VA Police Service physical access control system (PACS) so VA Police can control access to the facility parking areas, and (d) a firm-fixed-price service agreement covering a base year plus four (4) one-year option periods. 2. SCOPE OF WORK The Contractor shall furnish all management, supervision, labor, equipment, materials, tools, transportation, subscriptions, and subcontracted services (including the mandatory JCI subcontract in Section 5) necessary to remove the existing gate equipment and furnish, install, test, commission, warrant, monitor, and maintain a complete and operational parking gate and access control system at the 19 gate locations, in accordance with this SOW, manufacturer requirements, and the referenced codes and standards. Equipment brand names in this SOW, other than the JCI/PACS requirement in Section 5, are "or equal." 3. LOCATIONS AND EXISTING CONDITIONS Item Location / Type Quantity Notes 1 Barrier-arm gates (standard duty, 12 14 ft arm) 17 Parking lots and service drives; includes separated Fisher House locations. 2 Barrier-arm gate (long arm, approx. 20 ft) 1 Heavy-duty operator; status reporting appropriate to hardware. 3 Slide gate Utility Building 8 1 Reuse existing gate panel; convert from top track to bottom steel cantilever track. 4 Lots 3B and 4B Gates as installed (verify) Relocatable (forklift-movable) foundations and flexible wiring for planned two-way operation.
Total gate locations 19 Contractor shall verify all locations and conditions during the mandatory site visit.
Existing 120 VAC power is available at each gate location. Any electrical deficiency found during the site survey shall be reported in writing to the COR before installation; correction of pre-existing deficiencies will be addressed by modification if outside this scope. 4. TECHNICAL REQUIREMENTS GATE SYSTEM 4.1 Removal and Disposal Remove existing operators, arms, controls, and abandoned detectors at all 19 locations; legally dispose of all removed material off VA property (batteries recycled per EPA/DC regulations). Clean and prepare concrete pads. Removal and replacement shall be sequenced so that no parking area loses all vehicle access at once without a VA Police-approved traffic plan. 4.2 Barrier Gate Operators Commercial/industrial, high-cycle (continuous-duty) DC barrier operators listed to UL 325 and installed per ASTM F2200 where applicable. Integral or supplemental battery backup at every location. Behavior on loss of primary power (fail-open or fail-secure) shall be programmable per location and set as directed in writing by the Chief, VA Police Service. LED-illuminated arms (high-visibility), breakaway/swing-away arm flanges at standard-arm locations, and arm-displacement (arm-missing) contacts wired to the monitoring system. Above-ground radar ("virtual loop") vehicle detection configured for safety, arming, reset and free-exit functions as required per lane; no reliance on in-pavement loops at barrier locations. One (1) spare barrier operator, identical to the installed standard model, delivered to VA as Government property. 4.3 Slide Gate Utility Building 8 Convert the existing gate panel from top (aluminum) track to bottom steel cantilever track with carriages, guide rollers and fabrication as required. Furnish and install a high-traffic commercial DC slide gate operator rated for the gate weight/length, with battery backup, monitored contact edges, wireless edge transmitter, and photo-eye entrapment protection meeting UL 325 Type B1/B2 requirements; reconnect to existing loop detectors where serviceable. 4.4 Relocatable Foundations Lots 3B and 4B Provide relocatable, forklift-movable operator foundations and flexible wiring arrangements so the Contractor or VA can relocate operators for large deliveries or lot reconfiguration. Contractor shall confirm quantity during the site survey. 4.5 Remote Monitoring and Control Provide a remote I/O device at each of the 19 gates reporting operator fault, gate position, arm displacement, and communication-loss conditions, and relay outputs for remote open, hold-open, scheduled operation and release. The dashboard shall distinguish an operator fault from a communication loss, and an acknowledged relay command from confirmed gate position where feedback is available. All life-safety and entrapment-protection functions shall remain under local operator control; remote commands shall never override local safety devices. Communications shall use dedicated contractor-furnished cellular/wireless service used solely for the gate system. No component shall connect to the VA enterprise network except the JCI PACS equipment addressed in Section 5, and only as approved by VA OIT/ISSO. 4.6 Event Cameras Nineteen (19) IP cameras with alarm I/O, one per gate, compliant with Section 889 of the FY2019 NDAA (FAR 52.204-21/-24/-25/-26); with high-endurance local storage (minimum 256 GB) recording motion-based vehicle/person events. Cloud uploads limited to compressed event snapshots (gate-open and arm-displacement events); duplicate-trigger filtering configured to control cellular usage. Remote video viewing on demand only. 4.7 Cloud Platform, Information Security and Privacy The hosted management platform shall be FedRAMP authorized (Moderate or as determined by VA) or receive a VA Authority to Operate before hosted image or user-data features are activated. Until approved by the Information System Security Officer (ISSO) and Privacy Officer (PO), hosted image features shall remain disabled. All data, images and logs generated under this contract are VA records and VA property; the Contractor shall not use, sell or disclose them, and shall return or destroy them at contract end as directed by the CO. Contractor shall comply with VA Handbook 6500.6 and the security clauses incorporated in the contract. User access to the platform shall be limited to VA-designated personnel with unique accounts and multi-factor authentication. 4.8 Commissioning, Testing and Training Submit an Acceptance Test Plan 10 days before testing. Test every status contact, relay command, position feedback, arm-displacement trigger, camera event capture and upload, local recording and playback, power-loss/restoration behavior, communication loss and recovery, hold-open schedules, wireless coverage, and PACS-to-gate release at each location, witnessed by the COR and VA Police. Provide two (2) on-site training sessions (up to 4 hours each) for VA Police Service and Facilities Management on gate operation, manual release, event review, and requesting service; provide as-built drawings, O&M manuals, programming records and password/credential turnover. 4.9 Warranty Minimum one (1) year parts and labor warranty on the complete installed system (gate system and JCI-installed PACS equipment) beginning on the date of Government final acceptance. All manufacturer warranties (e.g., 2-year operator warranties) shall be passed through to VA. 5. MANDATORY SUBCONTRACT JOHNSON CONTROLS, INC. (PIV BADGE READERS) The VA Police Service PACS at the Washington DC VAMC is a Johnson Controls / Software House C CURE 9000 system with iSTAR-family controllers, installed and supported by Johnson Controls, Inc. To preserve system integrity, warranty and cybersecurity accreditation of that system, the following requirements apply: Subcontract required. The prime Contractor shall subcontract with Johnson Controls, Inc. (JCI) to furnish, install, program, test and commission ALL NEW badge readers and associated access-control hardware at each of the 19 gate locations. Offerors shall submit with their quote a JCI quotation or letter of commitment identifying the scope and price of the JCI work. The prime remains fully responsible to VA for JCI performance, schedule, and warranty. Readers. PIV/PIV-I credential readers listed on the GSA FIPS 201 Approved Products List, OSDP v2 secure channel, mounted on gooseneck pedestals at driver height (dual-height where trucks use the lane), compatible with the existing C CURE 9000 PIV authentication (FICAM) configuration. Controllers and communications. Software House iSTAR-family (or JCI-approved compatible) field controllers, enclosures, power supplies with battery backup and surge protection; communications path to the PACS head-end as approved in writing by VA OIT/ISSO and VA Police Service. Gate integration. Valid credential reads shall release the associated gate through a dry-contact interface coordinated between JCI and the prime; gate position and fault signals shall be made available to the PACS where supported. VA Police control. Upon completion, VA Police Service shall be able, from the C CURE workstation, to grant/revoke parking access by credential, set access levels and schedules by lot, lock down or hold open any gate, and view reader/door event history. Personnel. JCI technicians shall be factory-certified on C CURE 9000/iSTAR and shall meet the background investigation and privileged-access requirements for work on a VA network-connected security system. Service. For each option period exercised, the JCI subcontract shall include maintenance, firmware updates and repair of the readers and controllers installed under this contract. 6. SERVICE AGREEMENT (BASE YEAR + FOUR OPTION YEARS) The service agreement begins on the date of final acceptance of the installation and continues through the base period and each option period exercised by the Government. It covers all 19 gates and all equipment installed under this contract. 6.1 Preventive Maintenance (PM) Quarterly PM at each gate per manufacturer schedules, including UL 325 entrapment-device testing, battery load testing, arm/flange/sensor inspection, radar detector alignment, camera and storage health, and firmware review. Provide a written PM checklist per gate to the COR within 5 business days of each PM cycle. 6.2 Remote Monitoring Automated 24/7 monitoring of gate fault, communication-loss and arm-displacement alerts. Contractor shall review each alert and begin remote troubleshooting within 2 hours (business hours) or by 9:00 a.m. the next business day (after hours), and notify the COR/VA Police of any gate not restored remotely. 6.3 Corrective Maintenance and Response Times Priority Condition On-site response Restore / make safe Emergency Gate stuck closed blocking emergency vehicle route, or stuck open where VA Police declare a security need; safety hazard 4 hours, 24/7/365 Make safe / manual mode within 4 hours; restore within 24 hours Urgent Gate inoperable but alternate access available Next business day Within 2 business days (parts permitting) Routine Degraded function (camera, LED, single sensor) Within 3 business days Within 5 business days
Failures from normal wear, defects and equipment age are covered under the firm-fixed price (labor and parts) during warranty and under the service agreement thereafter. Damage from vehicle strikes, vandalism or acts of God is repaired under the Corrective Labor and Repair Parts CLINs at the fixed hourly rate and contract parts pricing, only after COR approval of a written estimate (emergency make-safe excepted). 6.4 Subscriptions and Data Services All cloud platform, monitoring, user, device and cellular data subscriptions required for system operation are included at a fixed annual price for each period. No surcharges, data overages or price increases are permitted except as priced in the option periods. 6.5 Performance Standard Monthly system availability of at least 98% per gate (excluding approved PM windows and damage caused by others). The Contractor shall report monthly availability, alerts, response times and repairs to the COR. 7. PERIOD OF PERFORMANCE AND SCHEDULE Period Estimated dates (adjust to award) Content Base Year 02/01/2027 01/31/2028 Installation complete within 120 calendar days after Notice to Proceed; JCI reader integration; warranty; service agreement and subscriptions from acceptance Option Year 1 02/01/2028 01/31/2029 Service agreement, subscriptions, JCI reader maintenance Option Year 2 02/01/2029 01/31/2030 Same as Option Year 1 Option Year 3 02/01/2030 01/31/2031 Same as Option Year 1 Option Year 4 02/01/2031 01/31/2032 Same as Option Year 1
Milestone Due Kick-off meeting (prime, JCI, COR, VA Police, OIT/ISSO, Safety) Within 10 days of award Site survey report, submittals (product data, shop drawings, NDAA certifications, FedRAMP/ATO evidence), installation schedule & traffic plan Within 30 days of award Installation start (after submittal approval) Per approved schedule Acceptance testing and training Within 120 days of NTP As-builts, O&M manuals, credential turnover Within 15 days after acceptance 8. HOURS OF WORK, ACCESS AND COORDINATION Normal work hours: Monday Friday, 7:00 a.m. 3:30 p.m., excluding Federal holidays. Work outside these hours requires 48-hour advance COR approval. Emergency service is 24/7. Contractor personnel shall check in with VA Police Service, wear VA-issued or company photo identification, and follow traffic-control plans meeting the MUTCD. Utility locates are required before any excavation or anchoring. The Contractor shall maintain at least one functioning entry and exit per parking area during working hours or provide manual operation coordinated with VA Police. 9. CONTRACTOR PERSONNEL SECURITY Contractor and subcontractor personnel shall complete background investigations at the risk level designated by the VA Position Designation Tool (anticipated Tier 1 / Low Risk for gate technicians; higher for JCI personnel with privileged PACS access) per VA Directive and Handbook 0710. Personnel requiring access to VA information or systems shall complete VA Privacy and Information Security Awareness and Rules of Behavior training before access and annually thereafter. 10. SAFETY, CODES AND STANDARDS UL 325 (Door, Drapery, Gate, Louver and Window Operators and Systems) and ASTM F2200 (Automated Vehicular Gate Construction) NFPA 70, National Electrical Code; OSHA 29 CFR 1910 and 1926; lock-out/tag-out FIPS 201-3 and GSA FIPS 201 Approved Products List; OMB M-19-17 (FICAM) VA Handbook 6500.6 (Contract Security); VA Directive 0730 (Security and Law Enforcement); VA Physical Security and Resiliency Design Manual FAR 52.204-25 (Section 889) and FAR 52.204-23/-27 prohibitions; Buy American / Trade Agreements as determined by the CO Manufacturer installation instructions 11. GOVERNMENT-FURNISHED ITEMS AND RESPONSIBILITIES Existing 120 VAC power at each location; access to sites with escort as required; VA Police PACS administrator support; VA OIT/ISSO review of PACS communications and cloud security documentation; designation of COR and alternate. 12. DELIVERABLES # Deliverable Due To 1 quotation / letter of commitment (with offer) With quote CO 2 Site survey report; installation schedule; traffic plan 30 days after award COR 3 Submittals incl. NDAA 889 and FIPS 201 APL certifications; FedRAMP/ATO evidence for cloud platform 30 days after award COR / ISSO 4 Acceptance Test Plan; completed test reports 10 days before test / at test COR 5 As-built drawings, O&M manuals, programming & credential turnover 15 days after acceptance COR 6 Quarterly PM checklists per gate 5 business days after each PM COR 7 Monthly performance report (availability, alerts, response, repairs) 10th day of following month COR 8 Written estimates for damage repairs Before work (except make-safe) COR 13. PERFORMANCE REQUIREMENTS SUMMARY Performance objective Standard Acceptable quality level Surveillance Installation complete All 19 gates and readers accepted Within 120 days of NTP COR inspection / test witness Preventive maintenance Quarterly PM at every gate 100% completed and documented PM checklist review Emergency response On site within 4 hours 95% of calls Call log / VA Police records System availability 98% per gate per month 98% Monthly report; platform data Remote alert review Within 2 business hours 95% of alerts Platform audit log

Similar Contracts

Same NAICS industry code

NAICS: 561621
New
Centennial Fire Alarm & CO Detection Upgrade and Maintenance Services
Solicitation # centennial-fire-alarm-co-detection-upgrade-maintenance-services
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum contract to provide fire alarm and CO detection upgrade and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The primary objective is to restore the central Simplex 4020 Fire Alarm Control Center Panel and connected systems across nine campus facilities to 100% normal operational status. The project requires technicians certified by NICET (Level II or higher preferred) and strict adherence to NFPA 101 (2024), NFPA 72, and local building and fire codes. Bids are due by December 1, 2026, and must include a detailed cost breakout and proof of insurance. A physical site visit and signature on the attendance roster are mandatory prior to bid submission. This opportunity is set aside for Small Businesses, including SBA certified Veteran Owned Small Businesses, Service-Disabled Veteran Owned Small Businesses, Women-Owned Small Businesses, and HUBZone Small Businesses. Bids equal to or greater than $25,000 require a bid bond of 20% of the base bid, as well as performance and payment bonds from a surety company with at least an A-rating. The project is subject to Construction Wage Rate Requirements (Davis-Bacon Act), requiring the payment of prevailing wages and the submission of weekly certified payroll reports. Award is based on overall best value, and the contractor must provide a one-year guarantee of workmanship upon completion.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 1 hour ago

DEADLINE

in 8 days
View Details
NAICS: 561621
New
SLED
Digital Watchdog Camera Installation at the Wicomico County Youth & Civic Center - Phase 2
Solicitation # 2027-IFB-040
Wicomico County Recreation, Parks, & Tourism is seeking bids for the Digital Watchdog Camera Installation at the Wicomico County Youth & Civic Center - Phase 2 under solicitation 2027-IFB-040. The project requires a qualified vendor to provide all labor, materials, and equipment to deliver a complete, operational low-voltage video surveillance system. The scope includes installing Cat6 cabling infrastructure with terminations and labeling, furnishing and installing various Digital Watchdog IP cameras and a Ubiquiti wireless point-to-multi-point system, and integrating these components into the existing Digital Watchdog Spectrum Video Management System (VMS). The contract will be awarded to the lowest responsive vendor who meets the specifications, including requirements for being licensed in Maryland and possessing over five years of similar work experience and expertise with Digital Watchdog VMS. Bids must be submitted via the OpenGov e-Procurement Portal by December 7, 2026. Required submission documents include a Maryland Certificate of Status, three references from the last 12-36 months, evidence of insurance, and a statement of current workload and capacity. The contract includes standard professional services terms, requiring a 15-day cure period for material breaches and a 30-day payment cycle upon receipt of a proper invoice. If the total contract value exceeds $100,000, the vendor must provide performance and payment bonds for 100% of the contract price within 14 days of receipt. There is no specified set-aside status for this solicitation.
Wicomico County Recreation, Parks, & Tourism

POSTED

about 5 hours ago

DEADLINE

in 14 days
View Details
NAICS: 561621
New
International
Maintenance of Fire Fighting Equipment, Hydrants, Wet/Dry Risers, Sprinkler Systems, Fire Risk Assessments, Specialist Labour and Passive Fire Protection Inspections (6232848)
Solicitation # ocds-h6vhtk-07c185
The Belfast Health and Social Care Trust, acting on behalf of several Northern Ireland health and emergency service entities, is soliciting proposals for the maintenance of fire fighting equipment, hydrants, wet/dry risers, sprinkler systems, fire risk assessments, specialist labour, and passive fire protection inspections. The scope of work is divided into four lots: Lot 1 covers fire extinguishers, blankets, hose reels, evacuation equipment, suppression systems, and signage; Lot 2 focuses on hydrants, risers, and sprinkler systems; Lot 3 involves fire risk assessments and specialist labour; and Lot 4 covers passive fire protection inspections. The total estimated contract value is 17,791,774 GBP excluding VAT. The contract is scheduled to run from February 24, 2027, to February 29, 2032, with an option to extend for up to 36 months, potentially ending February 28, 2035. Award criteria are based on a mandatory quality assessment regarding compliance with the Mid-Tier Schedule 2 Specification on a pass/fail basis, with the remaining score weighted 90% for price and 10% for social value. There is no specified set-aside status for this procurement. Proposals must be submitted in English via the electronic portal by December 18, 2026.
Belfast Health and Social Care Trust

POSTED

about 6 hours ago

DEADLINE

in 25 days
View Details
NAICS: 561621
New
Federal
H263--ANTI-LIGATURE DOOR ALARM INSTALLATION SERVICES
Solicitation # 36C26227Q0084
The Department of Veterans Affairs Network Contracting Office 22 is seeking a contractor to provide anti-ligature door alarm installation services for the San Diego VA Medical Center. This firm-fixed-price procurement, categorized under NAICS 561621, is a Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside. The scope of work involves the purchase and installation of a complete anti-ligature door alarm system for four mental health rooms, including the installation of infrastructure, head-end components, door-level hardware such as sensors and hinges, strobe lights, and sirens. The contractor is required to possess asbestos certification and provide a minimum one-year warranty on all equipment and workmanship. The period of performance is generally from November 20, 2026, to November 19, 2027, with specific installation deliverables including internal preliminary and formal final acceptance testing, staff training for 5 to 10 employees, and weekly electronic reporting to the COR. Award will be based on the most advantageous offer, evaluating technical approach, experience, and past performance, rather than using a lowest price technically acceptable method. Proposals must be submitted in PDF format for each evaluation factor, with the price schedule submitted separately. All offers are due by November 24, 2026.
262-NETWORK Contract Office 22 (36C262)

POSTED

2 days ago

DEADLINE

in 11 days
View Details

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 541519
New
Federal
DJ10--Alertus Enhanced Notification Licensing & Premier Support
Solicitation # 36C24527Q0081
The Department of Veterans Affairs, Network Contracting Office 5, is conducting market research to identify capable sources for software licensing and premier support of the Alertus emergency notification system at the Martinsburg VA Medical Center. The anticipated requirement is a firm-fixed-price contract consisting of one 12-month base period and four 12-month option periods. The scope of work includes providing software licenses, updates, security patches, and troubleshooting, while ensuring the system remains compliant with the VA Technical Reference Model, federal security requirements, and Section 508 accessibility standards. Key operational requirements include maintaining 24/7 trouble-call intake and completing software repairs within 48 hours, as well as preserving integration with the AtHOC Mass Notification System and existing public-address interfaces. Interested respondents must submit a concise capability statement by November 30, 2026, detailing their company information, licensing authorizations, and their ability to meet the 24/7 support and deployment requirements. The VA welcomes responses from all capable sources, including SBA-certified service-disabled veteran-owned small businesses and veteran-owned small businesses. This notice is for market research and acquisition planning purposes only and does not constitute a formal solicitation or a binding contract. No hardware supplies are anticipated for this requirement.
Other Computer Related Services

POSTED

3 days ago

DEADLINE

in 7 days
View Details
NAICS: 334515
New
Federal
Arc Flash Hazard Analysis Services
Solicitation # 36C24527Q0073
The Department of Veterans Affairs, Network Contracting Office 5 is conducting market research to identify qualified contractors capable of providing a complete arc flash hazard analysis and short circuit study for the Louis A. Johnson VA Medical Center in Clarksburg, West Virginia. The scope of work involves professional engineering services including field data collection, verification of as-built systems, and the development of computer models and one-line diagrams. The contractor must furnish and install durable, UV-resistant, and moisture-resistant arc flash warning labels on all analyzed equipment in compliance with ANSI Z535.4, IEEE 1584, and NFPA 70E standards. Key deliverables include a work plan, a final report, electronic model files, an equipment deficiency list for high-incident energy areas, and a technical briefing for VAMC engineering staff. This effort is structured with a base period and four twelve-month option periods. There is no set aside used for this procurement. Interested respondents must submit their Unique Entity Identifier, small business status under NAICS 334515, GSA schedule information, and a capability statement demonstrating relevant experience to the point of contact by December 1, 2026. All work must be coordinated through the Contracting Officer's Representative, and final acceptance of label installation is contingent upon a COR walk-through of at least 15 percent of the installed labels to ensure they match the final report.
Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals

POSTED

4 days ago

DEADLINE

in 8 days
View Details

Get AI-powered intelligence on this solicitation and the ones like it

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS