This Pre-Solicitation opportunity from Department Of Veterans Affairs was posted on April 8, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
K063--Crescent House EST4 Fire Alarm Upgrade Bedford VA Medical Center
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
General Info
Agency
NAICS
Place of Performance
Department of Veterans Affairs Networking Contracting Office 1 (NCO 1), Augusta, ME, 04330Set-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
Attachment 1 Sources Sought Worksheet QUALIFICATION INFORMATION: Company / Institute Name: _______________________________________________________ Address: ______________________________________________________________________ Phone Number: ________________________________________________________________ Point of Contact: _______________________________________________________________ E-mail Address: ________________________________________________________________ Unique Entity Identifier (UEI) #:Â ___________________________________________________ CAGE Code: __________________________________________________________________ Other available contract vehicles (GSA/FSS/NASA SEWP/ETC): ________________________ _____________________________________________________________________________ _____________________________________________________________________________ SOCIO-ECONOMIC STATUS: VIP Verified SDVOSB: (Y / N) VIP Verified VOSB: (Y / N) 8(a): (Y / N) HUBZone: (Y / N) Economically Disadvantaged Women-Owned Small Business: (Y / N) Women-Owned Small Business: (Y / N) Small Business: (Y / N) NOTE: Respondent claiming SDVOSB and VOSB status shall be registered and Center for Veterans Enterprise (CVE) verified in VetBiz Registry www.vetbiz.gov. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION. CAPABILITY STATEMENT: Provide a brief capability and interest in providing the Fire Alarm Upgrade at the Bedford VA as listed in Attachment 2 (STATEMENT OF WORK) with enough information to determine if your company can meet the requirement. The capabilities statement for this Sources Sought is not a Request for Quotation, Request for Proposal or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach, but rather the Government is requesting a short statement regarding the company s ability to provide the services outlined in the (SOW). Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement. This synopsis is for information and planning purposes only and is not to be construed as a commitment by the Government. The Government will not pay for information solicited. Respondents will not be notified of the results of the evaluation. ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________
Attachment 2 STATEMENT OF WORK Crescent House: EST4 Fire Alarm System Upgrade 1. Project Overview This Statement of Work outlines the requirements for upgrading the existing fire alarm system at Crescent House to the EST4 platform. The new system must provide enhanced fire detection, notification, integration capabilities, and compliance with all relevant codes and VA standards. 2. Objectives Replace the current fire alarm control panel and all compatible devices with the Edwards EST4 system. Ensure compliance with NFPA 72, VA Fire Protection Design Manual, and local authority having jurisdiction (AHJ) requirements. Minimize disruption to building occupants and operations during upgrade. 3. Scope of Work A. Site Assessment Conduct a pre-installation survey to verify current fire alarm system configuration, device locations, and building layouts. Identify areas requiring extra coverage or unique installation considerations. B. Design & Submittals Prepare detailed shop drawings, device layout, wiring diagrams, and sequence of operations. Submit plans for VA and AHJ review/approval before commencement. C. Equipment & Materials Supply and deliver EST4 fire alarm control panel and all required detectors, modules, pull stations, notification devices, power supplies, and batteries. All equipment must be UL-listed and compatible with the EST4 system. D. Installation Remove the existing fire alarm control panel and any obsolete hardware safely. Install EST4 system and all associated field devices as per the approved design. Ensure all wiring is in accordance with NEC and VA standards. Coordinate with related trades (e.g., IT for networking, electrical for power) as required. E. Testing & Commissioning Perform I/O point-to-point testing. Conduct full functional testing as per NFPA and VA requirements. Provide documentation of testing and as-built drawings. F. Training & Documentation Train Crescent House facility staff on system operation, troubleshooting, and basic maintenance. Provide all user manuals and training documents. G. Warranty & Support Minimum one-year warranty on all equipment and installation labor. Provide post-installation technical support by contract terms. 4. Deliverables Detailed design drawings and device lists. Submittal documents for VA/AHJ approval. EST4 system installed and fully operational. Testing/commissioning reports and as-built documentation. Training sessions and manuals for facility staff. 5. Schedule Kick-off & Assessment:Â Within 2 weeks of notice to proceed. Design/Submittals:Â 3-4 weeks. Installation:Â 4-6 weeks upon submittal approval. Testing & Training:Â 1 week. Total estimated duration: 8-12 weeks. 6. Standards & Reference Material National Fire Protection Association (NFPA 72) VA Fire Protection Design Manual Local codes and AHJ requirements EST4 System Manufacturer Guides 7. Roles & Responsibilities Contractor:Â Responsible for site assessments, design, installation, testing, training, and support. VA/Crescent House:Â Responsible for providing site access, facilitating coordination, and reviewing submittals. 8. Acceptance Criteria EST4 system operational with no deficiencies. All tests and documentation approved by VA authority and AHJ. Facility staff trained. 10. General Provisions All work to comply with VA sensitive data handling and site privacy requirements. All workers adhere to Crescent House safety and security regulations.
More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award