This Combined Synopsis/Solicitation opportunity from Department Of Health And Human Services was posted on August 24, 2020. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
Karl Fischer Volumetric Titrator, or equivalent
Closed
FDA-RFQ-20-1231540FederalSubmission Closed
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
General Info
Agency
Department Of Health And Human Services → FDA Office Of Medical Products And TobaccoView Agency
NAICS
334516 - Analytical Laboratory Instrument Manufacturing View NAICS
Place of Performance
Irvine, CA, 92612, USASet-Aside
NONE
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
1 update
PhaseClosed
Submission Closed
Organization & Contact Information
Show more
AgencyDepartment Of Health And Human Services → FDA Office Of Medical Products And Tobacco
Contacts2 people available
OfficeSilver Spring, MD, 20993, USA
Organization / Agency
Department Of Health And Human Services → FDA Office Of Medical Products And Tobacco
View Agency ProfileOffice AddressSilver Spring, MD, 20993, USA
Contacts
Marque Green
Gary Klaff
Full Description
Show more
The contractor shall provide a Mettler Toledo Karl Fischer Volumetric Titrator V30S or equivalent and a compatible compact printer or equivalent. The Karl Fischer Volumetric Titrator shall meet or exceed the following requirements: Instrument capable of performing water content determination on solid, liquid and gaseous samples. Equipped with burette recognition with titrant and concentration monitoring. Capable of adding at least 1 additional burette drive. Equipped with an integrated magnetic stirrer. Equipped with a solvent manager device. Capable of connecting to a printer via a RS232 interface. Color touchscreen for user interface. Has at least two user groups. Contains at least 100 programmed methods. Capable of at least 120 samples per series. Data is measured in time, water count, potential, volume and drift. Measurement range is at least 100ppm to 100%. Drift measurement is at least <5micrograms/minute Repeatability is minimally 0.3% at >10 mg H2O. The glass beaker must have a capacity of at least 150mls. The instrument must not exceed a footprint of 200mm x 330mm x 300mm. The printer shall meet or exceed the following requirements: Printing technology must be a dot matrix. Capable of printing at least 24 characters per line. Have a print speed of at least 2.3 lines per second. Utilize continuous label paper. Capable of connecting to a Karl Fischer Titrator via a RS232 interface. Equipped with auto-detect settings for connected devices.