Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on December 15, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Kentucky Lock Lift Pump Station Repair/Replacement

Closed
W912P5-26-Q-KLSRFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency is soliciting proposals under RFP-VC-26-010 for transformer oil testing services to enhance the reliability, safety, and maintainability of its transformers. The scope of work is divided into three primary areas: conducting visual and infrared thermographic inspections to identify thermal anomalies, installing standardized external oil sampling devices for safer collection, and performing detailed oil testing analysis. Additionally, the contractor is required to evaluate nitrogen blanket systems to ensure positive pressure is maintained, provide on-site training for agency staff on inspection tools, and develop comprehensive standard operating procedures. All work must adhere to strict technical and safety standards, including ASNT Level 1 certification for thermography, ASTM D923 and D924 for oil sampling, and NFPA 70E safety protocols. The agency intends to make a single award to the most capable and cost-effective offeror, evaluating candidates based on their staffing plan, personnel availability, fee structure, and a proven track record of performing similar projects for utilities or industrial facilities. Proposals must be submitted electronically via PlanetBids by December 23, 2026, and must include a detailed project approach, company profile, and required certifications such as non-collusion and workers compensation. The resulting contract will feature fixed pricing for an initial term with potential one-year extensions. Awardees must comply with California Labor Code prevailing wage requirements and maintain strict confidentiality regarding all agency reports and data.
Inland Empire Utilities Agency

POSTED

about 14 hours ago

DEADLINE

in 2 months
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management and Training Corporation is soliciting bids for a fixed-price, single lump sum contract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project involves a qualified electrical contractor inspecting, testing, repairing, and certifying emergency lighting systems across the facility, including the cafeteria, recreation building, and dormitories. Key tasks include performing functional tests by simulating utility outages, replacing failed ballasts with LED-compatible versions, and applying durable labels to fixtures for future tracking. The contractor must ensure full compliance with NFPA 101 (2024 Edition) and NFPA 70 standards, integrate recurring maintenance into the center's Computerized Maintenance Management System, and provide certificates of disposal for hazardous materials. The estimated contract value ranges from $25,000 to $100,000, with a performance period of 30 business days following the Notice to Proceed. Bids are due by December 1, 2026, and must include a detailed cost breakout and a mandatory physical site visit. For bids of $25,000 or more, a bid bond of 20% is required, and the awarded contractor must provide performance and payment bonds from a surety with at least an A- rating. This solicitation is set aside for small businesses and various SBA-certified categories. Award decisions will be based on overall best value. Compliance requirements include adherence to the Davis-Bacon Act, Federal Contractor Minimum Wage, and FAR regulations regarding work hours, safety standards, and the Buy American Act.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 14 hours ago

DEADLINE

in about 1 month

General Info

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Place of Performance

Grand Rivers, KY, USA

Set-Aside

SBA

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W072 Endist Nashville
Contacts2 people available
OfficeNASHVILLE, TN, 37203-1070, USA
Office AddressNASHVILLE, TN, 37203-1070, USA

Full Description

Show more

Request for Information: The Government is issuing this Request for Information to determine a competitive basis for the procurement described. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey.


This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.


Requirement: Contractor shall furnish all materials, supplies, tools, equipment, transportation, supervision, quality control, and labor necessary to complete this Scope of Work.  All materials and workmanship will be manufactured and accomplished according to industry standards and specifications. For additional information, reference the attached document, “Lock Wall Lift Station Pump Repairs Reference Document”.


  1. Two (2) new pumps, 40 GPM and 108 feet TDH, 5.0 HP, 3450 RPM, 460/3/60 Hz will be procured and installed within the Lock Wall lift station. The existing pump supports within the lift station are damaged and new pump supports will need to be installed. The contractor shall also verify if the Conery base can be reused without modification. If not, the contractor will be responsible for replacing the base. Costs estimated for this work shall include any pumping/removal of existing waste in the lift station that is required to complete this task safely. Reference the provided reference document for additional details related to existing utilities associated with the lift station.
  2. The existing lift station contains two (2) grinder pumps. One of the existing pumps has been removed and replaced. The removed pump shall be repaired to full functionality. The removed pump is a Zoeller Model G7112, 7.5 HP, 3450 RPM, 460/3/60 Hz, submersible high head grinder pump complete with 2 ½ inch horizontal discharge flange that is adaptable to 3-inch, SC/SC lower seal, 7.125-inch diameter impeller complete with 25-feet power & control cable.
  3. The contractor shall repair or replace the transducer associated with the lift station pump. The currently installed transducer is precision digital PDA6420 Split Core AC Current Transducer.
  4. The contractor shall replace “in-kind” the 2” check valve inside the wet well. The existing check valve is Flomatic Check Valves Model 508 Part Number 3235.
  5. The contractor shall replace “in-kind” the 2” ball valve inside the wet well. The existing ball valve is Flomatic Ball Valves Part Number SSBV1000-20. Verify operation of the new ball valve with the extension handle.
  6. The Contractor shall perform a functionality test to ensure the system works as intended. Test procedures describing the functionality test shall be submitted to the Government for review and approval. The following functions shall be tested to verify that they are functioning as intended by design:
    • Both pumps automatically run via the transducer system.
    • Both pumps automatically run via the float system.
    • The pumps automatically switch from the transducer system to the float system if the transducer system fails.

Period of Performance: The Period of Performance shall be performed within 30 calendar days of the award date.


Place of Performance:  


Kentucky Lock Resident Office


193 Taylor Park Rd.


Grand Rivers, KY 42045


NAICS: The anticipated NAICS code for this requirement is 238210 (Electrical Contractors and Other Wiring Installation Contractors) with a size standard of $19,000,000.


Survey: Please send responses to the Market Survey to Samantha Clay at Samantha.J.Clay@usace.army.mil  and Cierra Vega at Cierra.R.Vega@usace.army.mil by 12:00PM CT on December 29, 2025.


  1. Name of Firm:
  2. CAGE:
  3. Point of Contact (include email address)
  4. Are you classified as a small business under any of the following NAICS code:

  • 238210 (Electrical Contractors and Other Wiring Installation Contractors)

      5. If this requirement is advertised, do you anticipate submitting a quote?


      6. List three (3) projects completed within ten (10) years of the date of this notice that demonstrates experience with electrical and wiring installation:


  • Project Name / General Description:

           Contract Number (if applicable):


           Dollar Amount:


  • Project Name / General Description:

           Contract Number (if applicable):


           Dollar Amount:


  • Project Name / General Description:

           Contract Number (if applicable):


           Dollar Amount:

More opportunities from Department Of Defense → W072 Endist Nashville

Same awarding agency

NAICS: 53119
New
Federal
Office Space For US Army COE - Lenoir City, TN Area
Solicitation # DACW62526001
The Department of Defense, through the US Army COE Endist Nashville, is soliciting offers for the lease of approximately 900 to 1,525 rentable square feet of office and warehouse space in the Lenoir City, Tennessee area. The desired facility should be located within a 25-mile radius of Lenoir City, with preferred areas including Martel, Farragut, Cedar Bluff, Wood Creek West, Oak Ridge, Scarboro, and Hardin Valley. Required amenities include hardwall offices, a conference room, restrooms, a break room, broadband or fiber optic infrastructure, and approximately 6 to 8 public parking stalls. The lease is structured for an initial one-year term with four renewal options, targeting an occupancy date of January 1, 2027. The government will award the contract to the acceptable offer with the lowest price per square foot based on ANSI/BOMA Z65.I-1996 standards. Offerors must provide floor plans, a valid Certificate of Occupancy, and a Pre-Lease Building Security Plan. Key safety and security requirements include compliance with NFPA 101 Life Safety Code, ADA-ABA accessibility guidelines, and the installation of shatter-resistant material on all exterior windows. Additionally, the lessor must maintain accurate HVAC diagrams and strictly control access to mechanical areas and roofs. This solicitation falls under NAICS code 531190, and respondents must submit the required GSA representations and certifications regarding small business status and federal compliance.

POSTED

7 days ago

DEADLINE

in 7 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS