Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

Laboratory Capabilities to Test Railroad Tank Car Thermal Protection Systems (TPS)

Active
6913G627SS1002Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The U.S. DOT Volpe Center is issuing a Request for Information to identify qualified commercial or university laboratories capable of performing pool and torch fire tests on Thermal Protection Systems for railroad tank cars. The objective is to support Federal Railroad Administration research into preventing hazardous material releases during derailment fires. Testing must align with 49 CFR 179 Appendix B, though the research may require extended fire exposure durations, modified protocols, and additional data collection beyond standard requirements. Interested vendors must demonstrate the ability to conduct these tests and perform light fabrication and assembly of test specimens, including cutting steel plates and applying specific coatings. The government is seeking detailed information regarding facility capabilities, staff expertise, accreditation, hourly rates, lead times, and equipment availability. This RFI is for market research and planning purposes only and does not constitute a formal solicitation or a commitment to award a contract.

General Info

DOT seeks labs for railroad tank car thermal protection fire testing and fabrication.

NAICS

541380 - Testing Laboratories and Services

Place of Performance

Cambridge, MA, 02142, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Transportation → 6913G6 Volpe National Transportation System Cntr
Contacts1 person available
OfficeCAMBRIDGE, MA, 02142, USA
Office AddressCAMBRIDGE, MA, 02142, USA

Full Description

Show more

Request for Information (RFI) only.


Purpose


This RFI seeks information regarding Laboratory Capabilities to perform pool and torch fire tests of Thermal Protection Systems (TPS) to the U.S. DOT Volpe Center. A qualified vendor must be capable of performing pool and torch fire tests as described in 49 CFR 179 Appendix B.  The vendor should also be capable of performing light fabrication and/or assembly of test specimens for the aforementioned tests. Qualified vendors are requested to respond as detailed further below, which includes capability, small business classification, estimated lead time including any risks that may impact delivery, and any other industry concerns the government might consider before solicitation. The intent is to gather information to inform a possible future procurement or contract.



Background


The Federal Railroad Administration (FRA) is conducting research into the performance of TPS for railroad tank cars. TPS are designed to delay or prevent the catastrophic release of hazardous materials from a railroad tank car exposed to fires that may result from train derailments.  In the FRA’s planned research, test specimens of TPS are to be evaluated in simulated pool fire and torch fire conditions similar to those defined in Appendix B to 49 CFR 179. The durations of the fire exposure would extend beyond the 100 minute pool fire and 30 minute torch fire duration specified in Appendix B to 49 CFR 179.


Pool fire test specimens are applied to a 1 foot by 1 foot steel plate of nominal 0.625 inch thickness.


Torch fire test specimens are applied to a 4 foot by 4 foot steel plate of nominal 0.625 inch thickness.


The Volpe Center is looking to perform a minimum of two (2) pool fire tests and two (2) torch fire tests for each TPS. The total number of TPS to be tested has not yet been determined. 


Although the tests will be similar to those defined in 49 CFR 179 Appendix B, this research may require some modifications to the test protocol including but not limited to additional instrumentation, data collection or varying of test parameters such as duration of the fire exposure.


The Volpe Center is also looking for the capability to perform light fabrication of test specimens as detailed above.  For examples of possible fabrication requirements, see https://www.phmsa.dot.gov/standards-rulemaking/hazmat/tank-car-thermal-protection-system-list



Scope of Information Requested


  1. The U.S. DOT Volpe Center is seeking information from commercial testing laboratories, university laboratories, and other interested parties on their willingness, ability, and experience in conducting the simulated pool and torch fire testing planned for various tank car TPS. Descriptions of your facility’s pool and torch fire testing capabilities, including equipment, experience, capacity, resources and staff preparedness for testing tank car TPS. You are encouraged to submit publications of relevant past work.
  2. Descriptions of any laboratory accreditation or certification related to pool fire testing.
  3. Laboratory hourly rates, technical personnel rates, general facility and equipment usage charges, overhead and other expenses, etc.
  4. Descriptions of staff/facility/equipment availability, including any limitations on when fire testing may be conducted (e.g., blackout dates due to seasonal weather conditions)
  5. Information on any pre-test data or preliminary sample testing that may be required prior to a full-scale test.
  6. Information on your typical post-test laboratory analyses and report formats, and your ability to tailor report/data formats to customer requirements.
  7. Description of your facility’s fabrication and assembly capabilities, including:
    1. Cutting of 11 gauge steel sheet (0.1196 inches)
    2. Cutting of 0.625 inch steel plate
    3. Cutting of insulating materials that may generate hazardous airborne particulates such as fiberglass.
    4. Mixing and application of coatings to required specifications similar to examples on the PHMSA TPS list.
  8. What is the required lead time for fabrication of test specimens?
  9. Technical personnel rates, general facility and equipment usage charges, overhead and other expenses, etc. for fabrication of test specimens.
  10. Estimated time to conduct one simulated pool fire and one simulated torch fire test including setup, conduct of the test, cooldown, and teardown of test setup.
  11. Any other comments that can help the U.S. DOT Volpe Center better define the research scope and direction and ultimately yield technical data beneficial to both the government and industry are welcome.


Responses should include the above as well as:


  • Company information
    • Name
    • UEI
    • Address
    • POC information


This RFI is for information and planning purposes only and is a market research tool to determine the availability and adequacy of sources prior to determining the method of acquisition and possible issuance of a Request for Quotation (RFQ). This RFI does not constitute a solicitation for bids, quotations, and proposals, and is not to be construed as a commitment by the Government. The information provided herein is subject to change and in no way binds the Government to solicit for or award a competitive contract. All information submitted in response to this announcement is voluntary, and the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.


Similar Contracts

Same NAICS industry code

More opportunities from Department Of Transportation → 6913G6 Volpe National Transportation System Cntr

Same awarding agency

NAICS: 332999
New
Federal
Dunnage Bar Manufacturing
Solicitation # 6913G627RFI100
The Department of Transportation, through the Volpe National Transportation System Center, has issued a sources-sought Request for Information (RFI) under solicitation number 6913G627RFI100 for the manufacturing of approximately 1,000 dunnage bars modeled after the EVANS DF-1 loader crossbar. This effort is intended for market research and budgetary planning to determine the availability of capable business sources before a formal Request for Proposal is issued. The project requires a comprehensive manufacturing process including 3D scanning of sample parts, casting, machining, welding, and the assembly of 8-gauge steel Z-bars and oak wood components. Finished castings must be zinc plated or treated with commercial-grade black oxide. The dunnage bars must meet specific performance standards, including a uniformly distributed vertical load of 4,000 lbs, a concentrated center span load of 2,000 lbs, and a horizontal longitudinal restraint load of 4,000 lbs. This opportunity is designated as a Total Small Business Set Aside. Interested vendors must submit a Statement of Capabilities not exceeding 10 pages in PDF format to Andrew Josephs by October 23, 2026. Submissions should detail technical strategies, production capacity, lead times, rough order of magnitude costs, and relevant certifications such as ISO 9001, AS9100, or NADCAP.
All Other Miscellaneous Fabricated Metal Product Manufacturing

POSTED

6 days ago

DEADLINE

in about 22 hours
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS