Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on April 1, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

LCO2 Tank

Closed
FA560626QA023Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Agency

Department Of Defense → FA5606 52 Cons Da LgcView Agency

NAICS

332420 - Metal Tank (Heavy Gauge) ManufacturingView NAICS

Place of Performance

Spangdahlem, DE-RP, 54529, DEU

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA5606 52 Cons Da Lgc
Contacts2 people available
OfficeAPO, AE, 09126-3910, USA
Organization / Agency
Department Of Defense → FA5606 52 Cons Da Lgc
View Agency Profile
Office AddressAPO, AE, 09126-3910, USA
Contacts
Christine Zacchetti

Full Description

Show more

Spangdahlem AB is conducting market research for the below requirement. Be advised, this is NOT a solicitation, nor does it guarantee a solicitation for this requirement to be posted in the future.


This is an official request for information (RFI) to notify prospective offerors. Feedback is encouraged. Quotes are not currently being requested. Currently, there is no specialised foundation for the LCO2 tank to stand upon: is a specialised foundation required and if so, what specifications would such a foundation have to fulfill to safely support a long-term positioning of a LCO2 tank?


The purpose of this requirement is to provide a liquid CO2 storage tank with the following draft-requirements:
The tank should have a capacity of 6,000 - 7,000 liters and be a vacuum-insulated double wall tank consisting of two concentric vessels, a low-temperature resistant austenitic steel inner tank and an outer tank made of carbon steel with an anti-corrosion primer and a top coat of paint. The interspace between the two tanks should be filled with perlite insulating powder and an absorbent to maintain a vacuum pressure of < 0.05 millibar during tank operation. The maximum allowable working pressure for the inner vessel must be 22 bar gauge for temperatures ranging from -196° up to 20°C. It must supply pressurized LCO2 at 189-261 psi (13-18 bar) to a Dry Ice Production Hub through a flexible hose attachment. It will include a safety valve system to prevent overpressurizaton and a safety shutoff valve. The tank must be manufactured and tested in accordance with EU 97/23/EC and EN 13458. The company's Quality Management System must satisfy all elements of the EN ISO 9001/2000 program or ASME (U, U2, R-Stamp).


More opportunities from Department Of Defense → FA5606 52 Cons Da Lgc

Same awarding agency

NAICS: 561599
New
Federal
Lodging Agent Services for AMS Off-Base-Lodging
Solicitation # AMS-FA5606-01
The 726 Air Mobility Squadron at Spangdahlem Air Base requires lodging agent services to ensure the availability of at least 330 standard single rooms per day for personnel. The period of performance is expected to continue through approximately March 31, 2027, with the possibility of extension. The contractor is responsible for providing all management, tools, and personnel to coordinate reservations and assign personnel to lodging providers located ideally within 50km of the base. Key requirements include securing room rates within Department of Defense per diem limits according to Joint Travel Regulation guidelines and ensuring all facilities meet DoD and host-nation fire, safety, and physical security standards. Operational requirements include regular business hours supplemented by 24/7 on-call emergency resolution and the flexibility to adjust lodging availability during unscheduled operations or military exercises. The contractor must comply with NDAA Section 889 supply chain security restrictions and European General Data Protection Regulations. Financial obligations include invoicing via WAWF for management fees and allowable services, excluding German VAT through the use of NATO SOFA tax-relief documentation. The government will not pay for unoccupied rooms or cancellation fees unless specifically authorized under a funded Attrition CLIN with a pre-approved ceiling. Deliverables include monthly occupancy reports, billing reconciliations, and reservation rosters.
All Other Travel Arrangement and Reservation Services

POSTED

1 day ago

DEADLINE

in 5 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS