Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Georgia was posted on September 18, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Lunchroom Annex

Closed
PE-55407-NONST-2025-000000002State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 561210
New
Federal
J065--KG - HVAC upgrades (VA-27-00018970 / 36C245-27-AP-1028 / 512-27-1-444-0007 ) EDA: 12/11/2026 ; STATUS: Moved to Keysha Gorman for action on 11/6/2026 (DGM) ; NEED DATE 11-20-26 (unrealistic per PALT) MOVED TO BC FOR ASSIGNMENT
Solicitation # 36C24527Q0061
The Department of Veterans Affairs is seeking a contractor to perform HVAC upgrades at the VA Maryland Health Care System Building 1 Community Living Center of the Loch Raven Campus. The scope of work includes upgrading exhaust fans for the second floor B wing Covid Ward, installing heat tracing for chillers, and replacing cooling coils, fan motors, and Variable Frequency Drives in the kitchen basement. The contractor must coordinate with Johnson Controls International to integrate all new work into the existing Building Automation System and provide comprehensive training, O&M manuals, and shop drawings upon completion. This Small Business Set-Aside project has a period of performance of 90 calendar days. Award will be based on the best valued quote, evaluating price, past performance, and technical capability, specifically requiring documented experience in HVAC systems within healthcare or critical environments. All work must comply with strict safety and facility guidelines, including Infection Control Risk Assessment and Lock Out Tag Out procedures. Final payment is contingent upon the submission of a Testing Adjusting and Balancing report performed by a certified vendor and the approval of all O&M documentation by the government.
245-NETWORK Contract Office 5 (36C245)

POSTED

about 14 hours ago

DEADLINE

in 25 days
NAICS: 561210
New
Federal
Tinian IBB Facility Management
Solicitation # FA5025-27-Q-A008
The 356 ETSG is conducting market research via a sources sought notice to identify capable vendors for facility maintenance services at the Robert E. Kamosa Transmitting Station Facilities in Tinian, Northern Mariana Islands. This is not a formal solicitation but a request for information to determine the availability of sources under NAICS 561210. Interested vendors are asked to provide company details, including business size and CAGE/UEI codes, and offer feedback on the draft Performance Work Statement. The scope of work involves providing all labor, materials, and equipment for the sustainment, restoration, and modernization of buildings, structures, and critical systems, including HVAC, fire protection, electrical, and wastewater systems. Key requirements include the implementation of preventative maintenance programs and the execution of service orders with a liability limit of 2,500 dollars per order. Emergency services must be available 24/7, with a required response time of two hours and completion within 48 hours for integrated maintenance tasks. Technical qualifications are stringent, requiring personnel to be certified per DAFMAN 32-1067 for backflow prevention and requiring a NICET level III certification for fire protection management. Performance will be monitored by a Contracting Officer Representative through the Wide Area Work Flow system, with a mandatory Quality Control Plan due within 10 working days of a potential award. Invoicing and payments are processed through the Defense Finance Accounting System.
FA5025 356 Eceg Pk

POSTED

1 day ago

DEADLINE

in 5 days

AI Contract Overview

Show more

The contract involves the construction of a lunchroom annex designed to accommodate overflow from the existing lunch facility at Baconton Community Charter School in Georgia. The new building will measure approximately 60 feet in width, 80 feet in length, and 13 feet in height, featuring a single-slope metal roof. The project is valued between $300,000 and $500,000 and is being solicited as a formal procurement opportunity with a response deadline of October 4, 2024. Interested contractors can obtain further details or request a description of the project by contacting Larry Burkett via email or phone. This solicitation is issued by the Georgia Department of Education on behalf of the Baconton Community Charter School and is open to qualified vendors under NAICS code 561210. The project aims to expand the school's capacity to serve students efficiently during meal times, ensuring better handling of increased demand. The contract process is part of the state's efforts to improve school facilities and is accessible through the Georgia Procurement Registry, where additional information and updates can be found.

General Info

Documents

0

No documents available

No documents were posted with this contract.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

This one is closed. Find the next one like it.

Open contracts like this one, right now:

  • GMU-Sax SymposiumOpen now, due in 1 day
  • Sources Sought Notice - Robley Rex VAOpen now, due in 14 days
See open contracts like this

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

1 update
PhaseClosed
Posted

Solicitation

Notice updated

Solicitation number changed from 55407 BACONTON PE-55407-NONST-2025-000000002 to PE-55407-NONST-2025-000000002.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGeorgia → Baconton Community Charter School
Contacts1 person available
OfficeN/A

Full Description

Show more
We are planning to build a lunchroom annex to handle the overflow from our existing lunchroom facility. The building will be a 60' x 80' x 13' (W/L/H) with a single-slope metal roof. A description is available upon request by emailing Larry Burkett at Sign up to see this detail.

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS