MBEC Water Refuse and Implementation
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The contract involves a comprehensive upgrade to a pump station, including the removal of existing pumps and installation of two new dry-pit submersible pumps with a capacity of 1,500 gpm each. Additionally, a vertical automatic backwashing strainer will be installed in the basement to enhance filtration. The project encompasses electrical system enhancements, such as new panel boards, variable frequency drives, and a transformer, to support the upgraded equipment. HVAC improvements are also included, with the installation of exhaust fans, electrical room air conditioning, and an air scrubber system to meet specific ventilation and temperature standards. The scope further covers the provision and integration of new instrumentation and a Programmable Logic Controller (PLC) system, which will interface with the existing SCADA system for real-time monitoring and control. Piping systems will be replaced or upgraded to accommodate reclaimed water service, ensuring the infrastructure supports sustainable water reuse practices. The project is managed by the City of Chattanooga, Tennessee, with a contract value estimated between two and five million dollars, and responses are due by August 28, 2025. The primary contact for this solicitation is Debbie J Talley.
General Info
Place of Performance
TN, USASet-Aside
Documents
6AI Contract Breakdown
Uniform Contract FormatSign up to view the full breakdown with detailed analysis of each section.
View Full BreakdownThis one is closed. Find the next one like it.
Open contracts like this one, right now:
- 26350 Lynchburg, VA - CSO 70 Sewer ImprovementsOpen now, due in 17 days
- Lift Station No. 85 ReplacementOpen now, due in 28 days
Ask CLEATUS
I've read this contract. Ask me anything.
Timeline
Submission Closed
Organization & Contact Information
Full Description
•Pump Replacement: Remove existing pumps and install two new dry-pit submersible pumps, each rated at 1,500 gallons per minute (gpm). •Strainer Upgrade: Install one new vertical automatic backwashing strainer in the basement with the pumps. •Electrical Systems: Provide and install new electrical equipment in existing building, including panel boards, variable frequency drives (VFDs), and a transformer. •HVAC Improvements: Install new exhaust fans, air conditioning for the electrical room, and an air scrubber system to meet specified temperature and ventilation requirements. •Instrumentation and Controls: Provide, install, and integrate new instrumentation and a new Programmable Logic Controller (PLC) system with the existing Supervisory Control and Data Acquisition (SCADA) system to monitor and control the pump station. •Piping Systems: Install new piping designed for reclaimed water service.
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS