Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

N063--QUESTIONS & ANSWERS. NURSE CALL SYSTEM FOR DC VAMC. "BRAND NAME OR EQUAL TO IAW SOW". OEM LETTER FROM THE MANUFACTURER IS REQUIRED. IF NO OEM LETTER VENDOR WILL BE CONSIDERED NON-RESPONSIVE.

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This is a predicted recompete opportunity for a nurse call system at the DC VAMC, currently held by Standard Communications Inc with a contract value of 81,559.68 dollars. The project is a firm fixed price contract under a total small business set-aside, with a potential end date of October 17, 2026. The scope involves the installation of a standalone nurse call system, including the replacement of an existing Rauland 4 system and the expansion into a fourth bathroom. Key requirements include the installation of high and low push buttons for patient safety, the use of conduit for all cabling, and the provision of four dome lights. The contractor is responsible for determining the location of existing devices and head end equipment, as no mark-ups are provided. The project must be completed within 90 days of award and requires compliance with Infection Control Risk Assessment levels 2 through 4. Bidders must provide three past performance examples and a Buy American Certificate. A manufacturer OEM letter is mandatory for responsiveness. The final deliverable requires a one year manufacturer parts warranty and a three year workmanship warranty.

General Info

DC VAMC nurse call system installation, firm fixed price, total small business set-aside.

NAICS

334290 - Other Communications Equipment Manufacturing

Place of Performance

Washington DC VA Medical Center 50 Irving Street NW, MD, 204220001, USA

Set-Aside

SBA

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

pre-forecast

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Office AddressLINTHICUM, MD, 21090, USA
Contacts
Mohsin AbbasContract Specialist

Full Description

Show more
Predicted recompete opportunity based on federal award data.
Current Contract: 36C24526P0514 Incumbent: STANDARD COMMUNICATIONS INC Contract Value: $81,559.68 Potential End Date: 2026-10-17T00:00:00.000Z Competition: COMPETED UNDER SAP Pricing: FIRM FIXED PRICE Classification: recompete-likely (Confidence: medium - 55/100)
QUESTIONS & ANSWERS DURING THE RFQ 36C24526Q0598: On Attachment 2 3DE Floor Plans, there is no indication of existing devices. Will the government provide a mark-up of existing devices and location of head end equipment? ANSWER: There is no mark-up available for existing devices and would be the responsibility to be determined by the Contractor. Attachment 3 SOW, Page 1, 2.0 states The current system is partially functional as the call buttons have experienced water damage. Does the government have any documentation as to the extent of the water damage they can share with bidders? ANSWER: Upon assessment, Contractor can assess the extent of water intrusion at the call button location within the bathroom at the wall and government can describe repair attempts. Attachment 3 SOW, Page 1, 3.0 states The 3DE nurse call system will not be integrated with the facility s existing nurse call system and will only need to notify through localized alarm panels. Will the government confirm that all bidders will need to provide new head end equipment based on this requirement? ANSWER: The contract requirement as a standalone system is accurate. Attachment 3 SOW, Page 1, 3.0 states The existing system consists of 14 call buttons in 3 bathrooms. What is the current make and model? ANSWER: Existing system is Rauland 4 nurse call hardware or older. Attachment 3 SOW, Page 1, 3.0 states The existing system consists of 14 call buttons in 3 bathrooms. Has the government confirmed if the existing system meets the current Buy American Act requirements? Contracting requirement so I will defer but should not be applicable for existing systems. ANSWER: Existing system is Rauland 4 nurse call. Attachment 3 SOW, Page 1, 3.0 states The expansion will include a 4th bathroom along with six additional calls buttons that will require rough-ins and cable runs to the panel. Since pull cords are not allowed in behavioral health units, a push button is commonly installed instead. Neither the drawings or scope of work instruct offerors to include a high and low button or only a high mounted button. Does the government want high and low push buttons to allow patients to initiate a call in the event of a fall? ANSWER: High and Low push buttons are required to meet the requirements of this Contract. Attachment 3 SOW, Page 2, 3.0 states Contractor provides a proposal to include all the necessary materials, labor, and equipment to complete all required work within all documented areas. Contractor to reuse existing conduit/penetrations when able and when suitable for the functionality required by the Government. Installation of J-hooks is acceptable as needed. All existing nurses call cables and equipment to be removed by Contractor. Per the VA TIL Section 27-52-23, nurse call is a critical life safety system and must be installed in conduit. Will the government confirm that the entire system must be installed in conduit? ANSWER: Installation in conduit is the responsibility of the Contractor regardless of whether existing or new devices are utilized. Will the government confirm that the existing system identified in the SOW on page 2 as 14 call buttons in 3 bathrooms is already in conduit? ANSWER: Installation in conduit is the responsibility of the Contractor regardless of whether existing or new devices are utilized. Does the existing system have any existing integrations or software licenses i.e. Vocera, overhead paging, code blue, etc.? ANSWER: The Contract requirement is a standalone system. Attachment 1 RFQ 36C24526Q0598, Page 23, Section 13. Evaluation Factors, bullet iii. States Offeror will submit three (3) Past Performance. This usually requires three projects completed in the last 5 years of similar size and scope. Will the government provide more details on this to ensure compliant responses? Contracting requirement so I will defer. ANSWER: Please submit the three past performances as requested in the solicitation. If you would like to submit the three completed projects is up to the vendors for information purposes. Attachment 1 RFQ 36C24526Q0598, Page 23, Section 13. Evaluation Factors, bullet v. Instructs offerors to provide Buy American Certificates. Will the government consider requiring a signed affidavit from the manufacturer asserting that the entire solution meets the requirement, not only three pieces of hardware? Contracting requirement so I will defer. ANSWER: Please complete the Buy American Certificate to show COO for the line-item 1. Attachment 1 RFQ 36C24526Q0598, Page 21, Section 10. Infection Control Risk Assessment states It is the contractor s responsibility to work with Infection Control to determine the ICRA Level. The work is likely to be Level 2 but has the potential to go up to Level 4. Does the government know by now if it is level 2 or level 4? This significantly impacts offerors pricing based on equipment required.
ANSWER: ICRA level determination is dependent on the extent of work required, approval by Infection Control Specialist and is the responsibility of the Contractor to meet. Per Contract Specifications, work is likely to be level 2 but has the potential to go up to level 4.
Attachment 1 RFQ 36C24526Q0598, Page 19, Section 7. Period of Performance states Delivery within 90 days of contract award. Is this 90-day period of performance for the entire scope of the project or just for delivery of the requested hardware? ANSWER: The 90-day period of performance is for the entire scope of the project. Does the government require that behavioral health devices are true stainless-steel flush mounted anti-ligature devices, not generic devices with plastic coverings overtop? ANSWER: Beyond specifications of Contract. According to the DCVA staff, the current system has been inoperable for more than five (5) years. Has the government considered replacing all of the existing and new areas with a new system that will remain in support by the manufacturer longer and provide more features/capabilities? ANSWER: The government has considered replacement of the existing system. In most cases the government hosts a site visit for interested bidders, especially when construction tasks i.e. conduit, cabling, paint and patch, ICRA, etc. are required. Will the government allow for a site visit for this opportunity to allow bidders to better understand the scope of work required and current system conditions? ANSWER: Contracting requirement so I will defer but facility can allow a site visit after award without extension of POP. ANSWER: No site visit during RFQ. Please submit your response IAW SOW. Attachment 3 SOW, Page 1, 3.0 states The expansion will include a 4th bathroom along with six additional calls buttons that will require rough-ins and cable runs to the panel. There is no indication or icon in the drawings for a panel, where is the existing panel? ANSWER: There is no mark-up available for existing panels and would be the responsibility to be determined by the Contractor. Attachment 3 SOW, Page 2, has a quantity of 3 for dome lights but page 1 under locations as shown indicates 4 dome lights. Will the government clarify which is correct? ANSWER: There are 3 existing dome lights, but the Contract requirement is for a total of 4 dome lights. Will the government confirm the location of head end equipment and if power supplies or UPSs will be required in the event of a power outage? ANSWER: There is no mark-up available for existing equipment and would be the responsibility to be determined by the Contractor. UPS is not included in the requirements of this Contract. Attachment 3 SOW, Page 2 states that A manufacturer parts warranty for a minimum of 1 year shall be included. This is usually a standard five (5) year warranty on hardware required in VA TIL Section 27-52-23. Will the government require a five (5) year manufacturer s hardware warranty? ANSWER: The warranty requirement is as written in the SOW. Attachment 3 SOW, Page 2 states that A workmanship warranty for a minimum of 3 years shall be included. Does this include the existing system or only net new devices and associated installation work? ANSWER: Warranty requirement applies to the final deliverable regardless of whether existing or new devices are utilized.
NOTE: VHA-SERVICES-RFQ: 36C24526Q0598 VHA-SERVICES-RFQ-AMEND 36C24526Q0598 - 0001
All quotations shall be sent via email to Mohsin Abbas, Contract Specialist, Mohsin.Abbas2 @va.gov . Submission shall be received no later than 3:00 PM EST on June 30, 2026. Late submissions shall not be accepted. FAR 52.212-1(f)(1), RFO 52.212-1(c)(1). Only e-mailed quotes will be accepted. It is the responsibility of the vendor to ensure the Government s timely receipt of their quote.
Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Contract Specialist, Mohsin Abbas, contact@example.gov.

Similar Contracts

Same NAICS industry code

NAICS: 334290
New
Federal
IP-Based KVM Switching and Management System
Solicitation # PR514027
UT-Battelle, LLC, the Management and Operations Contractor for the Oak Ridge National Laboratory (ORNL), is soliciting firm fixed price quotes for an IP-Based KVM Switching and Management System under solicitation PR514027. The procurement, categorized under NAICS code 334290, seeks specific hardware including AdderLink Infinity manager devices, rackmount kits, control switches, expansion boxes, and receivers, or their domestic equivalents. Proposals must be submitted via email to the Procurement Officer by November 5, 2026. This is not a small business set-aside, and the brand name or equal provision under FAR 52.211-6 applies. The contract includes stringent security and compliance requirements, mandating adherence to NIST SP 800-171 for protecting controlled unclassified information and NIST FIPS 140-2 for encryption of personally identifiable information. Prohibited vendors include Kaspersky Lab, ByteDance, and specific telecommunications and surveillance entities such as Hytera, Hikvision, and Dahua. Sellers must maintain professional and cyber liability insurance with annual aggregate limits of 2,000,000 USD. Additionally, the agreement incorporates various FAR clauses regarding whistleblower rights, equal opportunity for veterans, and the Buy American Act for supplies exceeding 15,000 USD. Offerors must provide a unique entity ID and complete abbreviated representations and certifications to be considered.
Ornl Ut-Battelle Llc-Doe Contractor

POSTED

about 15 hours ago

DEADLINE

in 7 days
View Details

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 541330
New
Federal
C1DA--VISN 1 - INDEFINITE DELIVERY INDEFINITE QUANTITY ARCHITECT CONTRACT (Legacy VISN 5)
Solicitation # 36C24526R0107
The Department of Veterans Affairs, Network Contracting Office 5, is seeking an Indefinite Delivery Indefinite Quantity Architect and Engineering contract to provide ongoing engineering services for medical facilities and community based clinics within Legacy VISN 5, covering Maryland, West Virginia, and Washington D.C. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 541330, with a small business size standard of 25.5 million dollars. The overall contract value is not to exceed 450 million dollars over a ten year period. Work will be executed through firm fixed price task orders competed among awardees, with individual task order values ranging from a minimum of 2,500 dollars to a maximum of 2 million dollars. The anticipated solicitation date has been revised to late December 2026 or early January 2027, with a current response deadline listed as January 8, 2027. Prospective offerors must be registered in the System for Award Management and verified in the VetBiz Registry to be eligible for award. Interested parties are explicitly instructed not to submit SF330s during this pre-solicitation phase, as the current notices are for informational purposes only. All inquiries regarding this requirement should be directed via email to the contracting officer, Liana J Holland.
Engineering Services

POSTED

about 15 hours ago

DEADLINE

in 2 months
View Details
NAICS: 513210
New
Federal
7A21--CVI 42 Evolve Tier 1 License Subscription
Solicitation # 36C24527Q0045
The Department of Veterans Affairs, through the VA Maryland Health Care System, is soliciting a contract for CVI Evolve Tier 1 software licenses and support for the Cardiology department at the Washington DC VA Medical Center. The contractor is responsible for providing all necessary software licenses, parts, materials, labor, and training required to implement, maintain, and upgrade the system. The scope specifically includes two seats of the CVI 42 Evolve Tier 1 Subscription, covering advanced reporting and specialized modules such as 4D Flow, Aortic Valve, Cardiac MR, Circle Plaque, Core CT, Mitral Valve, Quantitative Perfusion, and Strain. The contract is structured with a base year running from January 1, 2027, to December 31, 2027, and four subsequent one-year option periods, extending the total potential duration to five years through December 31, 2031. Award will be granted to the responsible offeror whose proposal is most advantageous to the government, considering price and technical factors. Key requirements for offerors include providing a manufacturer's letter of authorization, detailed OEM implementation and training plans, and justification of compatibility with existing cardiovascular equipment. Administrative requirements specify that payments will be made in arrears upon receipt of a properly prepared invoice containing the contract and purchase order numbers, as well as the equipment serial numbers and model names. The contractor must comply with Buy American certifications, OSHA safety regulations, and Controlled Unclassified Information (CUI) protocols. Performance will take place at the Washington DC VA Medical Center, with the government retaining the right to inspect and test all services and supplies prior to acceptance.
Software Publishers

POSTED

about 15 hours ago

DEADLINE

in 7 days
View Details
NAICS: 561210
New
Federal
J044--NOTICE OF INTENT TO SOLE SOURCE Baltimore VAMC Steam System Preventive Maintenance from Vicinity Energy Baltimore Corporation
Solicitation # 36C24527Q0048
The Department of Veterans Affairs is issuing a Notice of Intent to Sole Source for an open market award to Vicinity Energy Baltimore Corporation to provide annual steam system preventive maintenance at the Baltimore VA Medical Center. This requirement, classified under NAICS code 561210 and PSC J044, is driven by the fact that the facility's steam equipment is directly connected to the district steam distribution system owned and operated by Vicinity Energy. Due to this interconnected configuration and the proprietary operational data involved, the government identifies Vicinity Energy as the sole source capable of ensuring the reliable operation of the system without risking the broader distribution network. The scope of work requires a two-person crew to provide eight hours of service every two weeks, totaling 416 labor hours per year. Key responsibilities include steam trap surveys, cleaning pressure-reducing valves, inspecting heat exchangers, and ensuring proper water chemistry and meter operation. The contractor must supply all necessary parts meeting original manufacturer specifications and provide emergency call-back services with a technician on-site within five hours of notification. The anticipated period of performance is one year from the award date, with the possibility of option-year extensions. Interested vendors may submit capability statements to Contract Specialist Patricia Thai by 11:00 AM EST on November 10, 2026, referencing announcement number 36C24527Q0048. These submissions will be used solely to determine if the procurement will be conducted on a competitive basis. All work will be performed at the Baltimore VAMC, adhering to strict VA security, safety, and infection control requirements.
Facilities Support Services

POSTED

1 day ago

DEADLINE

in 12 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS