NAVAL RESEARCH LABORATORY (NRL) FACILITY SUPPORT SERVICES (FSS)
Open
N4008027R1001Federal
Response Deadline
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
Show more
The Naval Research Laboratory (NRL) Facility Support Services contract is a small business set-aside, competitive Firm-Fixed Price agreement managed by NAVFAC Washington. The contract covers a primary period of performance from February 17, 2028, to February 16, 2036, with an optional six-month extension through August 16, 2036. The scope of work requires the contractor to provide all labor, management, and materials for comprehensive facility support at the NRL site in Washington, DC, including facility management, facility investment, integrated solid waste management, pavement clearance, and utility management for electrical, water, and wastewater systems.
This performance-based acquisition is divided into recurring and non-recurring work, utilizing the NAVFAC MAXIMO system for asset management, work control, and condition assessments. Key technical requirements include the maintenance of HVAC, fire protection, and electrical distribution systems, as well as strict adherence to safety and environmental protocols, such as the Spill Prevention, Control, and Countermeasure Plan. The contractor must provide qualified personnel, including a Project Manager, a CM/QOE certified Quality Manager, and a Site Safety and Health Officer. Additionally, the contract mandates rigorous cybersecurity compliance with NIST and DoD standards for personnel accessing Navy IT/OT systems and requires a detailed asset tagging program using 2D bar codes for all maintained equipment.
General Info
Small business firm-fixed price contract for NRL facility support services in Washington, DC.
4555 Overlook Ave SW, Washington, DC 20375, DC, 20375, USA
Set-Aside
SBA
Documents
198
PDF
PDF, High priority: read this firstsow
HighAI Summary for 1501000 – Facility Management Specifications: This document defines the performance work statement and technical specifications for facility management services at the Naval Research Laboratory in Washington, DC. It outlines requirements for work control, service request reception, personnel certifications, and the use of the NAVFAC MAXIMO system for asset management and infrastructure condition assessments.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for 1502000 Section J - Facility Investment: Section J of procurement 1502000 regarding Facility Investment. This document provides a comprehensive list of technical attachments (J-1502000-01 through 15) covering various facility systems (HVAC, Fire Protection, Electrical, etc.) and detailed definitions for maintenance terms, including Integrated Maintenance Program (IMP), preventive maintenance, and equipment categories.
PDF
PDF, High priority: read this firstsow
HighAI Summary for 1503030 - Integrated Solid Waste Management: This document is a Performance Work Statement (PWS) or Statement of Work (SOW) for Integrated Solid Waste Management services at the Naval Research Laboratory (NRL) in Washington, DC. It defines the requirements for refuse collection, disposal, and recycling, including specific tasks for bulky waste removal and non-recurring work. The document outlines personnel qualifications, reporting requirements for weight tickets, and performance standards for waste removal.
PDF
PDF, High priority: read this first5 pages · sow
HighAI Summary for 1503030 Integrated Solid Waste Management - Section C: This document is Section C (Performance Work Statement/Specifications) for the Integrated Solid Waste Management contract at the Naval Research Laboratory in Washington, DC. It outlines the requirements for refuse collection, disposal, and recycling, including specific mandates for bulky waste removal, personnel certifications, and the submission of weight tickets and disposal permits.
PDF
PDF, High priority: read this firstsupporting-documents
HighAI Summary for 1503030 Section J - Integrated Solid Waste Management Attachments: Section J of solicitation 1503030 for Integrated Solid Waste Management. This document contains critical supporting attachments, including definitions and acronyms (J-1503030-01), technical references (J-1503030-02), bulky waste tonnage data (J-1503030-03), and a detailed bulky waste frequency and collection points inventory (J-1503030-04).
PDF
PDF, High priority: read this firstsow
HighAI Summary for 1503060 - Pavement Clearance: This document specifies the requirements for pavement clearance services at the Naval Research Laboratory in Washington DC. It outlines the scope of work for both recurring services, such as pavement sweeping and snow removal, and non-recurring work ordered via task orders. The document includes performance objectives, standards, and requirements for personnel qualifications and equipment staging.
PDF
PDF, High priority: read this first5 pages · specifications
HighAI Summary for 1503060 Pavement Clearance Specifications: This document defines the technical specifications for Pavement Clearance services at the Naval Research Laboratory in Washington DC. It covers recurring pavement sweeping services and non-recurring snow removal operations, including personnel requirements, equipment restrictions (rubber tires only), and adherence to CNIC Service Level Standards.
PDF
PDF, High priority: read this firstsow
HighAI Summary for 1602000 Electrical Specifications - Naval Research Laboratory: This document outlines the technical specifications and performance objectives for the operation, maintenance, and repair of electrical distribution systems at the Naval Research Laboratory in Washington, DC. It defines the concept of operations, personnel certification requirements (UFC 3-560-01), safety standards (NAVFAC SAFE 101), and recurring work requirements for 24/7 electrical power distribution.
PDF
PDF, High priority: read this firstsow
HighAI Summary for 1604000 - Wastewater Technical Specifications: Technical specifications for the operation, maintenance, and repair of the Wastewater Collection System at the Naval Research Laboratory in Washington DC. The document outlines personnel certifications (Class Level 2), recurring work including preventive maintenance of pipelines and wet wells, and performance standards for effluent compliance and emergency response.
PDF
PDF, High priority: read this firstsow
HighAI Summary for 1606000 - Water Distribution System Specifications: This document specifies the requirements for the operation, maintenance, and repair of the Navy-owned water distribution system at the Naval Research Laboratory in Washington, DC. It outlines the concept of operations, personnel certification requirements (including DC Water Works Operators Certification Board), recurring work such as water quality monitoring and system operation, and performance standards for ensuring the safe distribution of drinking water.
XLSX
XLSX, High priority: read this first2 pages · specifications
HighAI Summary for Acid Neutralization Systems Inventory List: An inventory list of Acid Neutralization Systems (ANS) across various building locations, detailing tank sizes, quantities, and specific installation locations (e.g., basement mechanical rooms, subgrade vaults, and lab sinks).
XLSX
XLSX, High priority: read this first2354 pages · specifications
HighAI Summary for Assets Requiring Condition Assessment (J-1501000-07): An asset list identifying equipment requiring condition assessments, specifically focusing on HVAC systems including air compressors and air handling units at location NRL-1. The document provides asset numbers, descriptions, system classifications, installation dates, and specific room locations.
PDF
PDF, High priority: read this first1 page · specifications
HighAI Summary for Attachment A - Contractor Crane Operating Checklist for Critical Lifts: A safety checklist for contractor crane operators to use during critical lifts. The document contains 23 verification points covering load weight, crane capacity, outrigger stability, swing radius safety, rigging, and adherence to NAVFAC P-307 guidelines for electric power lines.
PDF
PDF, High priority: read this first2 pages · past-performance
HighAI Summary for Attachment D - Project Data Sheet (Factor 1 Corporate Experience): A Project Data Sheet form (Attachment D) for solicitation N4008027R1001. This document is used by offerors to provide detailed supporting project information to satisfy Factor 1, Corporate Experience, including contract values, performance periods, and self-performance percentages across various facility management and utility annexes.
XLSX
XLSX, High priority: read this first14 pages · specifications
HighAI Summary for Attachment J-0200000-06 Maximo Service Provider Information: Technical data interface specifications for Service Provider information integration with MAXIMO (Version VQU1, dated 18-Dec-17). The document defines a pipe-delimited file format, including a detailed field list with 35 positions (e.g., Work Type, Location, CLIN, Labor Costs), data format requirements, and a sample template for data submission.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Attachment J-0200000-10 Characteristic Meter Reading Information: Technical specification document detailing the data requirements for characteristic meter readings, including field names, required status, length limits, and corresponding NAVFAC MAXIMO fields. It also defines observation value codes for Facilities (DCR) ranging from Green to Red.
PDF
PDF, High priority: read this first1 page · specifications
HighAI Summary for Attachment J0200000 10 Characteristic Meter Reading Information: This document provides technical specifications for NAVFAC Maximo field data entry, specifically regarding characteristic meter readings. It defines required fields such as Site ID, Asset Number, Meter Name, and Observation values, including specific coding for Facilities (DCR) and Utilities (UCR) rankings.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Attachment J-0200000-11 MAXIMO Data Reporting: This document provides guidance for contractors on recording and submitting Service Provider, Asset, Specification, and Characteristic Meter Reading information into NAVFAC MAXIMO. It defines requirements for Work Order, Asset, and Condition Assessment data and mandates that data be submitted via Direct Entry into the system.
XLSX
XLSX, High priority: read this first63 pages · specifications
HighAI Summary for Attachment J-0200000-15 ELINs Blank: A blank pricing schedule and Exhibit Line Item Number (ELIN) template for a facility management solicitation. It includes a summary of CLINs for a base period and seven option periods, as well as detailed ELINs for recurring work including facility management, investment, solid waste management, utility management, electrical, and wastewater services.
XLSX
XLSX, High priority: read this first2453 pages · specifications
HighAI Summary for Attachment J-1501000-03 Facility Inventory Assets: A detailed facility asset inventory list for NRL-1, focusing on HVAC systems including air compressors and air handling units. The document provides asset numbers, descriptions, system classifications, installation dates, and specific room locations.
XLSX
XLSX, High priority: read this first3 pages · specifications
HighAI Summary for Attachment J-1501000-03 Facility Listing: A detailed facility listing (Attachment J-1501000-03) providing a comprehensive inventory of buildings, including facility numbers, names, build dates, and square footage. The list covers a wide variety of structures including laboratories, administration buildings, and specialized research facilities.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Attachment J-1501000-04 - NRL Site Map: A base map of the Naval Research Laboratory (NRL) site, including a legend for buildings, roads, fences, and geographical markers relative to the Potomac River.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Attachment J-1501000-06 Asset Tagging Guidance: This document provides technical specifications and requirements for the installation of asset tags with 2D bar codes for equipment maintained under the Inventory Management Program. It details the material requirements (polypropylene, 2.4 mil thickness), dimensions (2.43 x 3 inches), and the requirement for tags to match NAVFAC Maximo records.
XLSX
XLSX, High priority: read this first2354 pages · specifications
HighAI Summary for Attachment J-1501000-07: Assets Requiring Condition Assessment: This document is an asset list (Attachment J-1501000-07) detailing specific equipment requiring condition assessments. It includes a comprehensive table of HVAC assets, such as air compressors and air handling units, with details on location, asset numbers, system classifications, installation dates, and quantities.
XLSX
XLSX, High priority: read this first3 pages · specifications
HighAI Summary for Attachment J-1502000-02 Facility Listing: A detailed facility listing (Attachment J-1502000-02) providing a comprehensive inventory of buildings, including facility numbers, names, build dates, and square footage. The list covers various types of structures such as laboratories, administration buildings, and specialized research facilities.
XLSX
XLSX, High priority: read this first3 pages · specifications
HighAI Summary for Attachment J-1502000-03 Facility Listing: A detailed facility listing provided as Attachment J-1502000-03, containing a registry of facility numbers, names, build dates, and square footage for various laboratories, administrative buildings, and support structures.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Attachment J-1502000-03: Sample of E_U_R Orders: This document is Attachment J-1502000-03, providing samples of historical Emergency, Urgent, and Routine (EUR) orders. It includes a table structure designed to categorize work types and sub-work types for procurement reference.
XLSX
XLSX, High priority: read this first708 pages · specifications
HighAI Summary for Attachment J-1502000-05 HVAC and Refrigeration Systems: An asset inventory list for HVAC and refrigeration systems at location NRL-1. The document provides detailed technical specifications including asset numbers, descriptions, system classifications (D30 - HVAC), and installation dates for air compressors and air handling units.
XLSX
XLSX, High priority: read this first708 pages · specifications
HighAI Summary for Attachment J-1502000-05 HVAC and Refrigeration Systems: An asset inventory list for HVAC and Refrigeration Systems, identifying specific equipment such as air compressors and air handling units. The document includes asset numbers, descriptions, locations, installation dates, and system classifications for equipment located at NRL-1.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Attachment J-1502000-06 Temperature Standards: This document provides technical temperature standards for HVAC and refrigeration systems, specifying dry bulb Fahrenheit requirements for various areas including living, administrative, and working spaces across cooling and heating seasons.
XLSX
XLSX, High priority: read this first150 pages · specifications
HighAI Summary for Attachment J-1502000-07 Interior and Exterior Lighting Systems: An asset inventory list for interior and exterior lighting systems across multiple locations (NRL-1, NRL-2). The document provides detailed technical specifications including asset numbers, descriptions, system classifications, quantities, and installation dates for various lighting types such as fluorescent, incandescent, and high-intensity discharge.
XLSX
XLSX, High priority: read this first20 pages · specifications
HighAI Summary for Attachment J-1502000-08 Boilers and UPVs: An asset inventory list of boilers and Unpressurized Pressure Vessels (UPVs) across various NRL locations. The document provides detailed technical specifications including asset numbers, descriptions, HVAC system classifications, quantities, and installation dates for heat exchangers and expansion tanks.
XLSX
XLSX, High priority: read this first20 pages · specifications
HighAI Summary for Attachment J-1502000-08 Boilers and UPVs: An asset inventory list of Boilers and Untestable Pressure Vessels (UPVs) across various NRL locations. The document provides detailed technical data including asset numbers, descriptions, system classifications (HVAC), quantities, installation dates, and specific locations for heat exchangers and expansion tanks.
XLSX
XLSX, High priority: read this first5 pages · specifications
HighAI Summary for Attachment J-1502000-09 Cathodic Protection Systems: An asset list detailing Cathodic Protection Systems, including location, asset numbers, descriptions, and installation dates for specific electrical systems at NRL-30 and NRL-43.
XLSX
XLSX, High priority: read this first9 pages · specifications
HighAI Summary for Attachment J-1502000-10 Lightning Arrestors and Grounding Devices: An asset inventory list detailing lightning arrestors and grounding devices across various NRL locations. The document provides asset numbers, descriptions, system classifications, quantities, and installation dates for electrical grounding and protection systems.
XLSX
XLSX, High priority: read this first9 pages · specifications
HighAI Summary for Attachment J-1502000-10: Lightning Arrestors and Grounding Devices: An asset list detailing lightning arrestors and grounding devices across various NRL locations. The document includes asset numbers, descriptions, system classifications, quantities, and installation dates for electrical grounding and lightning protection systems.
XLSX
XLSX, High priority: read this first25 pages · specifications
HighAI Summary for Attachment J-1502000-11 Fire Protection Systems: An asset inventory list for fire protection systems across multiple locations (NRL-1 through NRL-32). The document details specific equipment including valves, risers, wet/dry pipe systems, fire pumps, and air compressors, including quantities, installation dates, and system classifications.
XLSX
XLSX, High priority: read this first15 pages · specifications
HighAI Summary for Attachment J-1502000-12 Compressed Air Inventory: An asset inventory list of compressed air systems across various NRL locations. The document provides detailed technical specifications including asset numbers, descriptions, system classifications (HVAC and Fire Protection), quantities, installation dates, and specific physical locations for each unit.
XLSX
XLSX, High priority: read this first15 pages · specifications
HighAI Summary for Attachment J-1502000-12 Compressed Air Inventory: An asset inventory list of compressed air equipment across various NRL locations. The document details asset numbers, descriptions, system classifications (HVAC and Fire Protection), quantities, installation dates, and specific physical locations for each unit.
XLSX
XLSX, High priority: read this first4 pages · specifications
HighAI Summary for Attachment J-1502000-13 Auxiliary Generator Systems: An asset inventory list of auxiliary generator systems, detailing locations, asset numbers, descriptions (including fuel type and capacity), and installation dates for various units across multiple NRL sites.
XLSX
XLSX, High priority: read this first4 pages · specifications
HighAI Summary for Attachment J-1502000-13 Auxiliary Generator Systems: An asset inventory list of auxiliary generator systems, detailing location, asset numbers, descriptions (diesel, gas, and electric), capacities (KW/KVA), and installation dates for various NRL sites.
XLSX
XLSX, High priority: read this first5 pages · specifications
HighAI Summary for Attachment J-1502000-14 Building Control Systems Inventory: An inventory list of Building Control Systems (Direct Digital Control/DDC) across various NRL locations. The document specifies asset numbers, descriptions, HVAC system classifications, installation dates, and quantities for main control panels.
XLSX
XLSX, High priority: read this first390 pages · specifications
HighAI Summary for Attachment J-1502000-15 Medium and Low Voltage Switchgear: An asset inventory list for medium and low voltage switchgear at NRL-1. The document provides a detailed breakdown of electrical assets, including motor control centers, safety switches, and panelboards, specifying asset numbers, technical types, amperage, voltage, and installation locations.
XLSX
XLSX, High priority: read this first390 pages · specifications
HighAI Summary for Attachment J-1502000-15 Medium and Low Voltage Switchgear: An asset inventory list for medium and low voltage switchgear, including panelboards, motor control centers, and safety switches. The document provides detailed technical specifications such as asset numbers, voltage, amperage, and installation locations for electrical distribution equipment.
XLSX
XLSX, High priority: read this first5 pages · specifications
HighAI Summary for Attachment J-1502000-16 POL Systems Inventory: An inventory list of Petroleum, Oil, and Lubricants (POL) systems, including pressure vessels and fuel storage tanks. The document provides detailed asset numbers, descriptions, master system classifications, installation dates, and locations for various facilities (e.g., NRL-149, NRL-210).
XLSX
XLSX, High priority: read this first12 pages · specifications
HighAI Summary for Attachment J-1502000-17 Backflow Prevention Devices: An asset inventory list of backflow prevention devices across various NRL locations. The document provides detailed technical specifications including asset numbers, pipe sizes, system classifications (Plumbing/Domestic Water Distribution), installation dates, and specific physical locations.
XLSX
XLSX, High priority: read this first12 pages · specifications
HighAI Summary for Attachment J-1502000-17 Backflow Prevention Devices: An asset inventory list of backflow prevention devices across various NRL locations. The document specifies asset numbers, descriptions, pipe sizes, installation dates, and precise locations within the plumbing and domestic water distribution systems.
XLSX
XLSX, High priority: read this first5 pages · specifications
HighAI Summary for Attachment J-1502000-18 Uninterruptible Power Supply: An asset list of Uninterruptible Power Supply (UPS) equipment, including asset numbers, descriptions, locations, and installation dates across various facilities (NRL-1, NRL-3, NRL-53, etc.).
XLSX
XLSX, High priority: read this first5 pages · specifications
HighAI Summary for Attachment J-1502000-18 Uninterruptible Power Supply Asset List: An asset inventory list for Uninterruptible Power Supply (UPS) systems, detailing location, asset numbers, descriptions, and technical specifications (KVA ratings) across various facility locations.
XLSX
XLSX, High priority: read this first8 pages · specifications
HighAI Summary for Attachment J-1502000-20 Overhead Doors: An asset list of overhead doors across various locations (NRL-2, NRL-3, NRL-30, NRL-36, NRL-49, NRL-57). The document provides technical details including asset numbers, door types (steel rolling, aluminum/fiberglass), operation methods (electric, manual), dimensions, and installation dates.
The purpose of this requirement is to provide facility management, facility investment, integrated solid waste, pavement clearance, and utilities services for facilities, ground structures, personal property equipment, and installed equipment and systems at the U.S. Naval Research Laboratory in Washington, D.C. More details can be found in the attached solicitation documents. Please note that there is a site visit scheduled for December 2nd and 3rd, 2026, which more details can be found in the solicitation.
Get AI-powered intelligence on this solicitation and the ones like it