Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 19 at 2:00 PM EDT

Register Free →

NOI Permit Rework 951UP

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Tidelands Oil Production Co. has received regulatory approval from the California Department of Conservation, Geologic Energy Management Division (CalGEM), to conduct a casing repair rework on an existing waterflood injection well, API #0403723763, known as 951UP, located in the Wilmington Oil Field on Pier A West in Los Angeles County. The work is limited to within the existing wellbore and established oil and gas well cellars, with no expansion of surface footprint or new infrastructure, and qualifies for exemption under CalGEM’s Group B rework guidance from December 2023 and several categorical exemptions under the California Environmental Quality Act, including Class 1 for existing facilities, Class 2 for replacement or reconstruction, and Class 4 for minor alterations to land. No significant environmental impacts are anticipated, as the site is fully developed for oil production, supports no native wildlife or botanical species, and all operations occur within hardened, contained areas. The activity is purely maintenance in nature, focused on restoring well integrity without increasing production capacity. The project is not subject to federal acquisition regulations as it is a state-regulated environmental permitting action, not a competitive procurement. There is no formal contract value, line-item pricing, or payment terms specified because no procurement process was conducted. The approval is administrative and regulatory, finalized by CalGEM in Long Beach, California, following field verification. The agency retains responsibility for inspection and acceptance, using environmental codes such as 14 CCR §§ 15301, 15302, 15304, and 1684.1 as the basis for compliance. No contract clauses, federal representation requirements, CAGE or UEI codes, socioeconomic certifications, delivery schedules, FOB terms, or invoicing procedures apply. The only identified point of contact for regulatory inquiries is Grayson Carlton, Associate Oil and Gas Engineer, with supporting administrative correspondence directed through CalGEM’s Southern District office. The work is time-sensitive and conducted under regulatory exemption, allowing prompt execution without a formal bidding or award process.

General Info

Tidelands to repair existing injection well 951UP in Wilmington Field under CalGEM exemption, no new infrastructure or production increase.

Agency

California Conservation, Department of

NAICS

213111 - Drilling Oil and Gas WellsView NAICS

Place of Performance

CA

Set-Aside

NONE

Documents

(1)

Notice of Exemption for NOI Permit Rework 951UP

PDFnotice-of-exemption

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia Conservation, Department of
Contacts2 people available
OfficeN/A
Organization / Agency
California Conservation, Department of
Office AddressN/A
Contacts
Grayson CarltonAssociate of Oil and Gas Engineer

Full Description

Show more
Tidelands Oil Production Co. proposes to rework 1 existing waterflood well in the Wilmington Field; the well is located on Pier A West. The rework consists of casing repair rework within the existing wellbore and fall under Group B of CalGEM’s rework exemptions guidance document published in December 2023. No impacts to wildlife are anticipated. The wellhead conductor is located in a concrete cellar. All work will occur within established oil and gas well cellars (trenches) in areas that provide minimal value as wildlife habitat. The Tidelands oil lease is entirely developed as an oil production facility and does not support wildlife or native botanical species. The proposed project consists of the California Department of Conservation, Geologic Energy Management Division (CalGEM) approving 1 permit for Tidelands Oil Production Co. to rework the well listed below, in the Wilmington Oil Field. API #: 0403723763 Well Name: 951UP

Similar Contracts

Same NAICS industry code

NAICS: 213111
New
Construction of the Monitoring Well AR-MW-04 IEUA 1158 Reservoir Site
Solicitation # construction-monitoring-well-ar-mw-04-ieua-1158-reservoir-site
The Inland Empire Utilities Agency is soliciting subcontractors to assist prequalified contractors in the construction of a nested monitoring well, designated AR-MW-04, located at the 1158 Reservoir Site in California. The well will consist of three 4-inch diameter monitoring well casings installed within a single borehole to a depth of approximately 1,000 feet, and will require full furnishing, installation, commissioning, and startup services. The work must be performed in accordance with all applicable technical and regulatory standards, and contractors must be prepared to deliver a fully operational system meeting the agency’s environmental monitoring objectives. This opportunity is set aside for small business concerns including Small Business, Small Disadvantaged Business, Women-Owned Small Business, HUBZone Small Business, Veteran-Owned Small Business, and Service-Disabled Veteran-Owned Small Business, as defined by the SBA. The solicitation was posted on August 7, 2026, with a response deadline of September 9, 2026. Interested parties should direct all inquiries to Jordan Villalobos, the primary point of contact, via email at jvillalobos@ieua.org or by phone at 909-993-1961. The North American Industry Classification System code for this procurement is 213111, indicating it falls under support activities for mining. The place of performance is in California, and while no specific city or zip code is provided, all work is expected to commence and conclude at the designated reservoir site. Proposals must align with the agency's procurement protocols and demonstrate capability in groundwater monitoring well construction and environmental compliance.
Inland Empire Utilities Agency

POSTED

about 7 hours ago

DEADLINE

in about 1 month