Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on July 8, 2010. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Outfitting Common Area

Closed
HE1260-0125-3000Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

238130 - Framing Contractors

Place of Performance

Okinawa, Japan, AP, JPN

Set-Aside

NONE

Documents

2

Outfitting Specifications - DoDEA Pacific Seal and Signage

PDF, High priority: read this firstspecifications
High

RFQ HE1260-0125-3000 - DoDEA Pacific Director’s Office Outfitting

PDF, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Combined Synopsis

Notice updated

Response deadline time changed from 5:00 PM UTC to 2:00 PM UTC on Jul 9, 2010. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Dodea Pacific Region Office
Contacts1 person available
OfficeAPO, AP, 96376-9001, USA
Office AddressAPO, AP, 96376-9001, USA
Contacts
Satomi MaedaContract Specialist

Full Description

Show more
Questions: 1. Main Logo: Depth of the main logo is not specified. Can we assume that approximately 2" deep is acceptable? Answer: The logo can not be thinner than 2". 2. Depth of Frames: The front face of the frames is specified as 1". Depth of the frames is not specified. Can we assume that approximately 1" to 1.5" deep is acceptable? Answer: Between 1.5" and 2" depth on frames. Total size of frame is 23.5" wide x 29.5" high. 3. Cast Lettering: Header and district letters specify "Helvetica cast metal lettering" "DIRECTOR'S OFFICE" letters specify "Helvetica cast aluminum lettering" Are you wanting a different look for the Director's letters or are they to be the same? Answer: Lettering to be identical in metal finish. 4. Frames For Maps: Are you asking for an exact match to the cast lettering or something close? If they have to match exactly then they will have to be cast metal and we will not be able to use standard moldings. Answer: Yes, we are asking for an exact, or as close as possible. 5. Shipping: Back in April when we were supplying Naomi with alternatives in their research process there was a discussion about the shipping issue. It was between Naomi (contact@example.gov), Gary Uno (contact@example.gov) & Jeff Bolles. (contact@example.gov). Answer: The shipping needs to be done internationally.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS