Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Michigan was posted on October 28, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Overhead and Underground Cable

Closed
37State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The City of Marshall Electric Department is soliciting bids for both overhead and underground electrical cables, specifically targeting two types of high-voltage aluminum conductors. The first specification involves #795 15kV Aluminum cable, which is a 19-strand, thermoplastic (TP) conductor with Hendrix-Gray or equivalent specifications, measuring 0.932 inches in diameter and weighing 1,049 pounds per 1,000 feet. The required quantity includes three reels of 3,000 feet each, totaling 9,000 feet. The second specification pertains to #1/0 15kV aluminum cable with a 220 mil EPR insulation, full neutral, and a sun-resistant polyethylene outer jacket with three red stripes. This cable features a stranded aluminum conductor, a continuous operating temperature of 90°C (with an emergency rating of 130°C), and comes in three reels of 2,500 feet each, totaling 7,500 feet. Bids must be submitted by 1 pm on November 12, 2025, with the opening held at City Hall in Marshall, Michigan. The contract is valued between $100,000 and $300,000, and interested parties can find additional information and submit bids through the city's official bidding portal.

General Info

Documents

18

2025 Chemical Bids for 2026 - Borough of Phoenixville

PDF, High priority: read this firstrfb
High

Bid No. 2025-004TF Eastside Reservoir PFAS Treatment Facility Advertisement for Bids

PDF, High priority: read this firstifb
High

Borough of Pompton Lakes Solid Waste Disposal Services Bid Notice

PDF, High priority: read this firstrfb
High

City of Casa Grande Golf Cart Fleet Bid 1024-25-CG-BID

PDF, High priority: read this firstitb
High

City of Casa Grande Solicitation 1024-25-CG-BID Golf Cart Fleet Purchase

PDF, High priority: read this firstrfb
High

Clarifiers 1, 2, & 3 Repaint - City of North Canton Advertisement for Bids

PDF, High priority: read this firstifb
High

COW Downtown Master Plan RFP Addendum 1

PDF, High priority: read this firstamendment
High

Granby Parks and Recreation Facilities Analysis Consultant RFP 102924

PDF, High priority: read this firstrfp
High

Hendersonville Firearms Exchange Competitive Sealed Proposal 2025

PDF, High priority: read this firstcsp
High

Mukilteo WWTF Electrical Improvements Addendum No. 1

PDF, High priority: read this firstamendment
High

Mukilteo WWTF Electrical Improvements Bidder Questions

PDF, High priority: read this firstq-and-a
High

MWWD 2024 WWTF Electrical Improvements IFB Drawings Feb 2025

PDF, High priority: read this firstifb
High

MWWD-2025 WWTF Electrical Improvements IFB Specs

PDF, High priority: read this firstifb
High

Notice to Bidders for Chemicals - Borough of Phoenixville

PDF, High priority: read this firstnotice-to-bidders
High

RFP Downtown Master Plan City of Woodstock IL 2025

PDF, High priority: read this firstrfp
High

Richards Drive Culvert Replacement Contract and Specifications

PDF, High priority: read this firstrfp
High

Sparwell Lane Culvert Replacement Contract and Specifications

PDF, High priority: read this firstcontract-document
High

Mukilteo WWTF Electrical Pre Bid Meeting Sign In Sheets

PDF, Low prioritysign-in-sheet
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

19 updates
PhaseClosed
Posted

Solicitation

Notice updated

Response deadline changed from Jan 16, 2025 to May 16, 2012. The notice title changed. NAICS code changed from 562211 to 333310. The notice description changed.

Notice updated

Response deadline changed from May 16, 2012 to Aug 2, 2013. The notice title changed. NAICS code changed from 333310 to 541330. The notice description changed.

Notice updated

Response deadline changed from Aug 2, 2013 to Oct 18, 2024. The notice title changed. NAICS code changed from 541330 to 221320. The notice description changed.

Notice updated

Response deadline changed from Oct 18, 2024 to Oct 4, 2024. The notice title changed. NAICS code changed from 221320 to 561720. The notice description changed. The point of contact changed.

Notice updated

Response deadline changed from Oct 4, 2024 to Oct 11, 2024. The notice title changed. NAICS code changed from 561720 to 333924. The notice description changed. The point of contact changed.

Notice updated

Response deadline changed from Oct 11, 2024 to Oct 2, 2024. The notice title changed. The notice description changed.

Notice updated

Response deadline changed from Oct 2, 2024 to Oct 24, 2024. The notice title changed. NAICS code removed. The notice description changed.

Notice updated

Response deadline changed from Oct 24, 2024 to Dec 2, 2024. The notice title changed.

Notice updated

Response deadline changed from Dec 2, 2024 to Jan 16, 2025. The notice title changed. NAICS code added: 562111.

Notice updated

Response deadline changed from Jan 16, 2025 to Jan 10, 2025. The notice title changed. NAICS code removed. The notice description changed.

Notice updated

Response deadline changed from Jan 10, 2025 to Mar 14, 2025. The notice title changed. NAICS code added: 332994. The notice description changed.

Notice updated

Response deadline changed from Mar 14, 2025 to Apr 15, 2025. The notice title changed. NAICS code changed from 332994 to 713910. The notice description changed.

Notice updated

Response deadline changed from Apr 15, 2025 to May 9, 2025. The notice title changed. NAICS code changed from 713910 to 333924. The notice description changed.

Notice updated

Response deadline changed from May 9, 2025 to Jun 24, 2025. The notice title changed. NAICS code removed. The notice description changed.

Notice updated

Response deadline changed from Jun 24, 2025 to Jul 17, 2025. The notice title changed. The notice description changed.

Notice updated

Response deadline changed from Jul 17, 2025 to Sep 14, 2025. The notice title changed. NAICS code added: 325180. The notice description changed.

Notice updated

Response deadline changed from Sep 14, 2025 to Oct 3, 2025. The notice title changed. NAICS code changed from 325180 to 236220. The notice description changed.

Notice updated

Response deadline changed from Oct 3, 2025 to Oct 21, 2025. The notice title changed. NAICS code changed from 236220 to 541310. The notice description changed.

Notice updated

Response deadline changed from Oct 21, 2025 to Nov 12, 2025. The notice title changed. NAICS code changed from 541310 to 335931. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyMichigan → City of Marshall
ContactsNo contacts available
OfficeN/A
Organization / AgencyMichigan → City of Marshall
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
City of Marshall Electric Department is seeking bids for overhead and underground electrical cable.SPECIFICATION #1- #795 15kV Aluminum. 19-strand, TP, Hendrix-Gray or equivalent#795 Covered Conductor 15kV AL Cable• Hendrix catalog # S0795PA15G3-00 or equivalent• Size 795.0kcmil• 19 Strands• Compact with conductor diameter of 0.932 inches; cable weight of 1,049 per 1000 ft.• Length tolerances Minimum -0%. Maximum +5%• Quantity: (3) 3000’ reels, totaling 9,000’SPECIFICATION #2- #1/0 15kV 220 mil, AL, EPR, full neutral7,500’ #1/0 15kV 220mil AL Full Concentric Neutral MV cable:• #1/0 class B stranded aluminum center conductor• 90°C continuous operating temperature, 130°C emergency rating (MV-90 minimum, MV-105 preferred).• EPR insulated, 220mil (133%) insulation level.• Semi-conducting, extruded, strand and insulation screens.• Full capacity outer neutral conductor comprised of bare copper wires.• Sunlight resistant polyethylene outer jacket with three red stripes.• Sequential footage marker printed on outer jacket.• (3) 2,500' non-returnable wood reels.• Length tolerances Minimum -0%. Maximum +5% Quantity: (3) 2,500’ reels, totaling 7,500’Bids are due by 1pm on November 12, 2025.Bids will be opened and read aloud in City Hall Council Chambers; located at 323 W. Michigan Ave, Marshall, MI 49068

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS